{"id":10551,"date":"2026-11-17T21:33:42","date_gmt":"2026-11-17T18:33:42","guid":{"rendered":"https:\/\/risys.sa\/?post_type=product&#038;p=10551"},"modified":"2026-11-18T20:56:13","modified_gmt":"2026-11-18T17:56:13","slug":"apc-e3sups30khb-three-phase-ups","status":"publish","type":"product","link":"https:\/\/risys.sa\/en\/product\/apc-e3sups30khb-three-phase-ups\/","title":{"rendered":"APC E3SUPS30KHB 30 kVA Three-Phase UPS, Internal VRLA"},"content":{"rendered":"<p>The APC E3SUPS30KHB is a 30 kW \/ 30 kVA three-phase UPS for 400V supplies that keeps its batteries inside the cabinet: it is built around internal VRLA batteries, the sealed, valve-regulated lead-acid type that needs no electrolyte top-ups. Among the 30 kVA models in the APC three-phase family, it is the straightforward balance of coverage and cost: full 30 kW capacity for the critical load of a floor or a mid-sized server room, delivered as one unit that is installed, connected and commissioned without a separate battery cabinet to source and house. For buyers who want protection in place quickly and do not need to engineer a long runtime, this is the model that keeps the project simple. Its kW and kVA ratings are equal, so the whole capacity is usable as real power.<\/p>\n<h2>Saudi sites suited to the APC E3SUPS30KHB<\/h2>\n<p>Typical fits include the records and medical imaging systems of a private clinic; a retail chain&#8217;s regional distribution centre, where warehouse management servers, scanners and CCTV share one protected board; the security operations room of a residential compound; the network room of a university faculty building; and an office floor in a business district in Riyadh or Dammam. On every one of these sites, cooling of the UPS room is the biggest single factor in VRLA battery life, because these batteries age faster in heat, and a Saudi summer is unforgiving to an unconditioned room.<\/p>\n<h2>What it does day to day<\/h2>\n<p>The unit sits between the three-phase 400V supply and the board feeding your critical loads. When mains power fails or sags, the internal VRLA batteries carry the load, so servers, network equipment and security systems stay up, and the batteries recharge once mains returns. Because the batteries are internal, backup time is set by how heavily you load the unit: running well below 30 kW buys more minutes than running close to the rating. Use that time to shut systems down in an orderly way or to bridge the gap until a generator takes over.<\/p>\n<h2>Where it sits among the 30 kVA models<\/h2>\n<p>The E3SUPS30KH takes an external lead-acid battery system instead, which is the better route when backup time must be extended with dedicated battery cabinets. The E3SUPS30K3IB2 also keeps its batteries inside the unit, but in a different internal string configuration, and the E3SUPS30KHB2 is the other 30 kW \/ 30 kVA variant in the line. If the load is lighter, the E3SUPS15KHB is rated 15 kVA and the E3SUPS20KHB2 is rated 20 kVA. For larger loads, the E3SUPS40KHB2 rises to 40 kW \/ 40 kVA and the E3SUPS60KHBS reaches 60 kVA \/ 60 kW.<\/p>\n<h2>Deployment notes<\/h2>\n<p>Provide a three-phase 400V supply and leave the choice of breakers and cable sizes for a 30 kVA load to your electrical designer. Have a qualified electrician carry out connection and commissioning following the supplied installation guide, and keep the supplied dust filter fitted and cleaned as part of routine maintenance. Treat the VRLA batteries as a consumable: log their installation date at commissioning and plan their replacement before a weak battery set reveals itself in the first long outage.<\/p>\n<h2>Package Contents<\/h2>\n<ul>\n<li>Dust filter<\/li>\n<li>Installation guide<\/li>\n<\/ul>\n","protected":false},"excerpt":{"rendered":"<p>A 30 kW \/ 30 kVA APC three-phase UPS for 400V supplies with internal VRLA batteries, delivering ready protection for critical loads in one self-contained unit without a separate battery cabinet.<\/p>\n","protected":false},"featured_media":21103,"comment_status":"open","ping_status":"closed","template":"","meta":{"_acf_changed":false},"product_brand":[716],"product_cat":[845,706],"product_tag":[],"class_list":["post-10551","product","type-product","status-publish","has-post-thumbnail","product_brand-apc","product_cat-three-phase-ups","product_cat-ups-backup-power","first","onbackorder","sale","taxable","shipping-taxable","purchasable","product-type-simple"],"acf":[],"_links":{"self":[{"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/product\/10551","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/comments?post=10551"}],"version-history":[{"count":1,"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/product\/10551\/revisions"}],"predecessor-version":[{"id":10552,"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/product\/10551\/revisions\/10552"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/media\/21103"}],"wp:attachment":[{"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/media?parent=10551"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/product_brand?post=10551"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/product_cat?post=10551"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/product_tag?post=10551"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}