{"id":10872,"date":"2026-11-17T21:33:30","date_gmt":"2026-11-17T18:33:30","guid":{"rendered":"https:\/\/risys.sa\/?post_type=product&#038;p=10872"},"modified":"2026-11-17T21:33:30","modified_gmt":"2026-11-17T18:33:30","slug":"apc-ap6020a-rack-pdu","status":"publish","type":"product","link":"https:\/\/risys.sa\/en\/product\/apc-ap6020a-rack-pdu\/","title":{"rendered":"APC AP6020A Zero U Rack PDU, 13 C13 Outlets, C20 Inlet"},"content":{"rendered":"<p>The APC AP6020A is a Zero U rack PDU whose power rating is written for higher-voltage racks: it accepts 100-240 volts at its IEC 320 C20 inlet and is rated for 200-240 volts on the output side, distributing that supply to 13 IEC 60320 C13 outlets. The unit ships without an input cord, so the connection to the building supply is chosen on site to match each rack&#8217;s feed. That is the trait that distinguishes it in APC&#8217;s rack PDU range: rather than a fixed cord, the installer specifies the cord, which suits facilities that work to their own cabling standard. The vertical Zero U body mounts in the cabinet&#8217;s side space and uses no rack units, and APC covers the unit with a 2 year warranty, a point procurement teams can record against the asset from day one.<\/p>\n<h2>How the APC AP6020A works in the cabinet<\/h2>\n<p>Mounted vertically along the side of the rack, the strip runs its 13 C13 outlets down the height of the cabinet, so servers, switches and storage at any position connect with a short cord. No rack unit is given up to power distribution, which matters in cabinets planned to the last U. The C20 inlet sits at one end of the strip, and because no cord is attached, the feed can be brought from under a raised floor or from an overhead tray with a cord chosen at the right length rather than coiling the excess inside the rack.<\/p>\n<h2>Saudi applications<\/h2>\n<p>Data centres and telecom operators in the Kingdom typically standardise cabinet feeds and cord types across a whole hall; a PDU without a captive cord fits that discipline, since every rack uses the approved cord for its circuit. Server rooms in ministries, banks and healthcare groups can roll the AP6020A out along rows fed at 200-240 volts. Integrators delivering surveillance and access-control head-ends for airports, stadiums and industrial cities can fit one strip per cabinet to power recorders, storage and network switches without losing rack positions.<\/p>\n<h2>AP6020A against the AP6003A and AP6015A<\/h2>\n<p>The AP6003A is the closest alternative: also a Zero U strip on a C20 inlet, with a slightly longer row of C13 outlets and a 20A maximum input current on the AP6003A, it suits racks whose load is planned around that current. The AP6015A is a different class of unit, a horizontal 1U strip with fewer outlets and a 15A maximum input current on the AP6015A, intended for small cabinets. The AP6020A is the choice when the rack is fed at 200-240 volts, when the site supplies its own input cord, and when a 2 year warranty matters for the procurement file.<\/p>\n<h2>Installation notes<\/h2>\n<p>Order the input cord together with the PDU, matched to the C20 inlet at one end and to the rack&#8217;s supply outlet at the other, and confirm that the rack&#8217;s supply voltage suits the unit&#8217;s 200-240 volt output rating before connecting equipment. Fix the strip in the vertical side space before servers are racked, so outlet positions can be checked against each power supply. The installation guide and safety guide included in the box describe mounting and connection.<\/p>\n<h2>Package Contents<\/h2>\n<ul>\n<li>Installation guide<\/li>\n<li>Safety guide<\/li>\n<\/ul>\n","protected":false},"excerpt":{"rendered":"<p>An APC Zero U rack PDU with 13 IEC 60320 C13 outlets and an IEC 320 C20 inlet, rated for 100-240 volt input and 200-240 volt output. It ships without an input cord and carries a 2 year warranty.<\/p>\n","protected":false},"featured_media":21080,"comment_status":"open","ping_status":"closed","template":"","meta":{"_acf_changed":false},"product_brand":[716],"product_cat":[851],"product_tag":[],"class_list":["post-10872","product","type-product","status-publish","has-post-thumbnail","product_brand-apc","product_cat-power-distribution-pdu","first","onbackorder","sale","taxable","shipping-taxable","purchasable","product-type-simple"],"acf":[],"_links":{"self":[{"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/product\/10872","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/comments?post=10872"}],"version-history":[{"count":1,"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/product\/10872\/revisions"}],"predecessor-version":[{"id":10873,"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/product\/10872\/revisions\/10873"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/media\/21080"}],"wp:attachment":[{"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/media?parent=10872"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/product_brand?post=10872"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/product_cat?post=10872"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/product_tag?post=10872"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}