{"id":10892,"date":"2026-11-17T21:33:27","date_gmt":"2026-11-17T18:33:27","guid":{"rendered":"https:\/\/risys.sa\/?post_type=product&#038;p=10892"},"modified":"2026-11-17T21:33:27","modified_gmt":"2026-11-17T18:33:27","slug":"apc-ap7820b-metered-rack-pdu","status":"publish","type":"product","link":"https:\/\/risys.sa\/en\/product\/apc-ap7820b-metered-rack-pdu\/","title":{"rendered":"APC AP7820B Metered Rack PDU, 1U, 8 x C13 Outlets"},"content":{"rendered":"<p>The APC AP7820B is a metered rack PDU sized for racks whose load stays modest. Its input is rated for a maximum current of 12A at 208V and 10A at 230V, drawn through an IEC 60320 C14 input plug, and it feeds 8 IEC 60320 C13 outlets from a 1U horizontal chassis. That combination makes it the entry point of the APC metered range in our catalogue: a C14 plug goes straight into a C13 socket, the outlet type found on the output panel of many UPS units, so the rack does not need a dedicated high-current feed. For a network cabinet holding a core switch, a firewall, a pair of servers and a storage appliance, the 10A ceiling at 230V is usually enough, and the meter lets the person responsible for the rack see how close the load is getting to that ceiling before another device goes in.<\/p>\n<h2>What the APC AP7820B does in practice<\/h2>\n<p>Each of the 8 C13 outlets takes the standard C14-ended power cord used by most servers, switches, routers, NVRs and storage appliances, so the cabinet needs no adapters and no daisy-chained power strips. The meter gives the technician a reading of the total load at the rack, which matters on a unit with a 10A limit at 230V: it is the difference between planning a new server against a known figure and discovering the limit unexpectedly during a busy period. The 1U horizontal format mounts at the front or rear of the rack, so it can sit behind the equipment it feeds and keep power cords short and tidy. A cord retention bracket ships with the unit to hold plugs in place against an accidental tug during maintenance.<\/p>\n<h2>Where it fits on Saudi sites<\/h2>\n<p>The AP7820B suits the smaller rooms that make up much of the installed base across the Kingdom: the comms room of a bank branch, a school network cabinet, the back-office rack of a pharmacy chain, or the security room of a residential compound where an NVR, a PoE switch and a router share one cabinet. In government and semi-government buildings that run a central data centre plus many floor-level cabinets, it gives each floor cabinet a metered distribution point without over-specifying the feed. Retail and hospitality operators with many branches can standardise on one model, so field technicians know exactly what they will find in every cabinet.<\/p>\n<h2>AP7820B versus its siblings<\/h2>\n<p>Within the APC metered line, the deciding factor is the feed. The AP7821B keeps the same horizontal format and C13 outlets but raises the maximum current to 16A at 208-230V and moves to a C20 input plug; choose it when the rack load will exceed what the AP7820B can carry. The AP7822B is a different class of unit, built for an input of 32 A on an IEC 60309 connector, and belongs in dense server racks rather than network cabinets. If the cabinet needs more than 10A at 230V, the AP7820B is the wrong choice and the AP7821B is the natural step up.<\/p>\n<h2>Deployment notes<\/h2>\n<p>Before ordering, total the nameplate or measured draw of every device that will plug into the unit and compare it with 10A if the rack is fed at 230V, or 12A on a 208V supply, leaving headroom for growth. Confirm that the upstream socket, typically a UPS output, accepts the C14 plug. Plan the position in the rack: the PDU occupies 1U, mounting it at the rear keeps the front free for equipment, and the supplied rack mounting brackets fix it in place. APC covers the unit with a warranty of 24 months.<\/p>\n<h2>Package Contents<\/h2>\n<ul>\n<li>Cord retention bracket<\/li>\n<li>Installation guide<\/li>\n<li>Rack mounting brackets<\/li>\n<li>User manual<\/li>\n<\/ul>\n","protected":false},"excerpt":{"rendered":"<p>A metered rack PDU for moderate loads: 1U horizontal chassis, 8 IEC 60320 C13 outlets and a C14 input plug, rated at 12A on 208V or 10A on 230V.<\/p>\n","protected":false},"featured_media":21076,"comment_status":"open","ping_status":"closed","template":"","meta":{"_acf_changed":false},"product_brand":[716],"product_cat":[851],"product_tag":[],"class_list":["post-10892","product","type-product","status-publish","has-post-thumbnail","product_brand-apc","product_cat-power-distribution-pdu","first","onbackorder","sale","taxable","shipping-taxable","purchasable","product-type-simple"],"acf":[],"_links":{"self":[{"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/product\/10892","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/comments?post=10892"}],"version-history":[{"count":1,"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/product\/10892\/revisions"}],"predecessor-version":[{"id":10893,"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/product\/10892\/revisions\/10893"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/media\/21076"}],"wp:attachment":[{"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/media?parent=10892"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/product_brand?post=10892"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/product_cat?post=10892"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/product_tag?post=10892"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}