{"id":10972,"date":"2026-11-17T21:33:23","date_gmt":"2026-11-17T18:33:23","guid":{"rendered":"https:\/\/risys.sa\/?post_type=product&#038;p=10972"},"modified":"2026-11-17T21:33:23","modified_gmt":"2026-11-17T18:33:23","slug":"apc-ap8706s-ww-power-cord-kit","status":"publish","type":"product","link":"https:\/\/risys.sa\/en\/product\/apc-ap8706s-ww-power-cord-kit\/","title":{"rendered":"APC AP8706S-WW Locking C13 to C14 Power Cord Kit, 1.8 m"},"content":{"rendered":"<p>Where the PDU and the equipment it feeds sit far apart in a cabinet, the APC AP8706S-WW supplies locking power cords long enough to make the run without strain. Each lead is 1.8 m, with an IEC 60320 C14 plug at the input end and an IEC 60320 C13 connector at the output end, and the kit is rated at 10 A. That 10 A rating defines the job: it places the cords in the standard connector class used by servers, switches, firewalls, storage shelves and recorders, rather than the heavier loads that need larger connectors. The lock keeps each cord seated if it is pulled by accident during maintenance. Among APC&#8217;s locking cord kits, it is the long-reach option for buyers who need the same 10 A rating over a greater distance between outlet and device, and it takes no space in the cabinet because it does not mount there.<\/p>\n<h2>APC AP8706S-WW on long rack runs<\/h2>\n<h3>Reaching the top of the cabinet<\/h3>\n<p>A 1.8 m lead reaches from a PDU mounted at the bottom of a full-height cabinet to equipment installed near the top. It also leaves enough length to route cords through cable managers and side channels instead of straight across the back of the equipment, which keeps the server exhaust path open and makes it easier to trace each cord to its outlet when a fault has to be found.<\/p>\n<h3>Keeping the connection made<\/h3>\n<p>A longer cord is heavier and more likely to snag on something along its length. The lock stops the cord&#8217;s own weight, or a pull somewhere along its run, from drawing the connector out of the device inlet, so the connection holds until a technician releases it on purpose.<\/p>\n<h2>Saudi projects where the length pays off<\/h2>\n<p>Data centres and colocation halls in Riyadh and the Eastern Province use deep, full-height cabinets in which the PDU may be mounted well away from the equipment it serves, and the extra length removes the temptation to add extension leads. In network rooms at universities, hospitals and shopping centres, switches often sit at the top of the rack above a PDU near the floor. Surveillance projects that combine NVRs, decoders and storage in one cabinet need cords that can be dressed neatly along the rails. Control buildings at oil and petrochemical facilities need connections that will not part during routine maintenance work.<\/p>\n<h2>When to choose AP8706S-WW over the shorter kits<\/h2>\n<p>The AP8704S-WW and AP8702S-WW use the same locking design with shorter leads, which suit equipment mounted close to the PDU and leave less slack to manage. The AP8712R serves a different load class, with larger higher-current connectors and left- and right-angled heads. Choose the AP8706S-WW when your measured runs exceed what the shorter kits reach; if they do not, the extra length simply becomes slack that has to be coiled and tied.<\/p>\n<h2>Planning the installation<\/h2>\n<p>Measure the route the cord will actually follow, including turns through cable managers, rather than the straight-line distance from outlet to device. Confirm that the PDU outlets are C13 and the device inlets are C14, and keep the load on each cord within 10 A. The kit is a cabling accessory rather than rack-mountable hardware, and it carries a 24-month warranty.<\/p>\n<h2>Package Contents<\/h2>\n<ul>\n<li>Power cord (locking C13 to C14) \u00d7 6<\/li>\n<\/ul>\n","protected":false},"excerpt":{"rendered":"<p>Locking power cords from an IEC 60320 C14 plug to a C13 connector, rated at 10 A with 1.8 m per cord. The long-reach option for feeding equipment that sits away from the PDU in the cabinet.<\/p>\n","protected":false},"featured_media":21070,"comment_status":"open","ping_status":"closed","template":"","meta":{"_acf_changed":false},"product_brand":[716],"product_cat":[706,849],"product_tag":[],"class_list":["post-10972","product","type-product","status-publish","has-post-thumbnail","product_brand-apc","product_cat-ups-backup-power","product_cat-ups-accessories","first","onbackorder","sale","taxable","shipping-taxable","purchasable","product-type-simple"],"acf":[],"_links":{"self":[{"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/product\/10972","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/comments?post=10972"}],"version-history":[{"count":1,"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/product\/10972\/revisions"}],"predecessor-version":[{"id":10973,"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/product\/10972\/revisions\/10973"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/media\/21070"}],"wp:attachment":[{"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/media?parent=10972"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/product_brand?post=10972"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/product_cat?post=10972"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/product_tag?post=10972"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}