{"id":10977,"date":"2026-11-17T21:33:22","date_gmt":"2026-11-17T18:33:22","guid":{"rendered":"https:\/\/risys.sa\/?post_type=product&#038;p=10977"},"modified":"2026-11-17T21:33:22","modified_gmt":"2026-11-17T18:33:22","slug":"apc-ap8712r-power-cord-kit","status":"publish","type":"product","link":"https:\/\/risys.sa\/en\/product\/apc-ap8712r-power-cord-kit\/","title":{"rendered":"APC AP8712R Angled C20 Jumper Cord Kit, 16 A, 0.6 m"},"content":{"rendered":"<p>The APC AP8712R is a kit of short angled jumper cords for high-draw rack equipment: each lead is 0.6 m long, terminates in an IEC 60320 C20 plug and is rated for a maximum of 16 A. The kit mixes left-angle and right-angle cords, so each connection can turn toward the side where the PDU sits instead of projecting straight back from the device. That combination of a larger connector, a higher current and an angled head separates it from the standard cord kits in APC&#8217;s range, such as the AP8706S-WW, which is rated at 10 A. It suits equipment that needs more current than standard cords carry, such as blade chassis, large storage arrays and core switches, in cabinets where the device sits close to the PDU. As a cabling kit, it takes no space in the cabinet.<\/p>\n<h2>How APC AP8712R angled cords work in a rack<\/h2>\n<p>A straight head projects from the back of a device and needs room before the cord can bend. In a crowded cabinet that can stop the rear door from closing or load the connection point. An angled head sends the cord out parallel to the face of the device straight away, which relieves strain on the connector and keeps the rear space clear for airflow and for hands.<\/p>\n<p>Having both directions in one kit solves a practical problem: a device to the right of the PDU needs a head that turns left, and a device to its left needs the opposite. At 0.6 m, each cord bridges a device and a nearby PDU without slack gathering at the bottom of the cabinet, which matters more with the thicker cords that carry higher current.<\/p>\n<h2>Saudi facilities with high-draw racks<\/h2>\n<p>Data centres in the Kingdom are moving to denser cabinets as cloud computing and heavy processing loads grow, and those cabinets hold equipment that calls for 16 A cords rather than standard ones. Core telecom sites and bank core-system rooms need short, orderly connections for large routing and storage equipment. Hospitals keep medical imaging archives on storage arrays, and oil and gas facilities run control and monitoring servers; both benefit from a cord that neither protrudes nor gets pulled in a crowded cabinet.<\/p>\n<h2>Where AP8712R sits against AP8704S-WW and AP8706S-WW<\/h2>\n<p>The AP8704S-WW and AP8706S-WW provide locking cords for standard-current loads at greater lengths, and the AP8706S-WW is rated at 10 A. The AP8712R is the short, higher-current option in the family, meant for equipment whose needs exceed what those kits carry, when the device sits in the same cabinet close to the PDU. If the distance between outlet and device is longer than 0.6 m, this kit will not cover it.<\/p>\n<h2>Deployment notes<\/h2>\n<p>Confirm that the PDU has outlets that accept a C20 plug and that the run from outlet to device is no longer than 0.6 m. Decide the head direction for each device before connecting, since a left-angle cord cannot stand in for a right-angle one in the same position. Keep the load on each cord within 16 A. The kit is not rack-mountable, and it carries a 24-month warranty.<\/p>\n<h2>Package Contents<\/h2>\n<ul>\n<li>Left-angle jumper cord \u00d7 3<\/li>\n<li>Right-angle jumper cord \u00d7 3<\/li>\n<\/ul>\n","protected":false},"excerpt":{"rendered":"<p>Short 0.6 m jumper cords with an IEC 60320 C20 plug and a 16 A maximum current, in left-angle and right-angle versions. Built for high-draw equipment mounted close to the PDU.<\/p>\n","protected":false},"featured_media":21069,"comment_status":"open","ping_status":"closed","template":"","meta":{"_acf_changed":false},"product_brand":[716],"product_cat":[706,849],"product_tag":[],"class_list":["post-10977","product","type-product","status-publish","has-post-thumbnail","product_brand-apc","product_cat-ups-backup-power","product_cat-ups-accessories","first","onbackorder","sale","taxable","shipping-taxable","purchasable","product-type-simple"],"acf":[],"_links":{"self":[{"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/product\/10977","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/comments?post=10977"}],"version-history":[{"count":1,"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/product\/10977\/revisions"}],"predecessor-version":[{"id":10978,"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/product\/10977\/revisions\/10978"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/media\/21069"}],"wp:attachment":[{"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/media?parent=10977"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/product_brand?post=10977"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/product_cat?post=10977"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/product_tag?post=10977"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}