{"id":11045,"date":"2026-11-17T21:33:19","date_gmt":"2026-11-17T18:33:19","guid":{"rendered":"https:\/\/risys.sa\/?post_type=product&#038;p=11045"},"modified":"2026-11-17T21:33:19","modified_gmt":"2026-11-17T18:33:19","slug":"apc-apdu9953-switched-rack-power-distribution-unit","status":"publish","type":"product","link":"https:\/\/risys.sa\/en\/product\/apc-apdu9953-switched-rack-power-distribution-unit\/","title":{"rendered":"APC APDU9953 Switched Rack PDU, 32A 230V, 21 C13 + 3 C19"},"content":{"rendered":"<p>The APC APDU9953 is the high-current unit in this part of APC&#8217;s 9000 Switched range. It is rated 32A at 230V, so a single feed can carry the load of a fully populated server or network cabinet rather than a lightly filled one. It provides 21 C13 outlets for servers, switches, storage shelves and recorders, plus 3 C19 outlets for the heavier equipment that ships with high-current power cords, such as large server chassis, storage arrays and high-output PoE switches. The body is ZeroU: it mounts vertically in the rear channel of the rack and takes none of the rack units you would otherwise give to active equipment. As a Switched model, it lets an administrator turn individual outlets on and off remotely, which turns a frozen device into a remote restart rather than a site visit.<\/p>\n<h2>What the APC APDU9953 does in a loaded cabinet<\/h2>\n<p>The 32A rating is the reason to choose this unit. Cabinets that hold dual-processor servers, storage and core switching draw far more than a typical office circuit can supply, and spreading that load across several smaller PDUs means more feeds, more cords in the rear of the rack and more points to manage. The APDU9953 concentrates it into one strip, provided a qualified electrician sizes the upstream circuit and breaker for a 32A, 230V load.<\/p>\n<p>The split of 21 C13 and 3 C19 outlets reflects how real cabinets are populated: most devices take the common C13 socket, while a few heavy devices need the larger C19. Putting those few on C19 outlets avoids adapter cords and keeps each device on the socket it was designed for.<\/p>\n<p>Vertical mounting places the outlets alongside the equipment, which shortens cord runs and keeps the rear of the rack tidy enough to trace a cable quickly during a fault.<\/p>\n<h2>Where it fits in Saudi facilities<\/h2>\n<p>The APDU9953 suits server rooms and small data halls in banks, hospitals, universities and government entities, where one cabinet can hold virtualisation hosts, storage and core switches together. It also fits the central equipment room of a large CCTV project, such as a stadium, an airport terminal, a shopping mall or an industrial plant, where recording servers and storage share a rack with aggregation switches. In each case the switched outlets let the operations team restart a hung recorder or switch from the control room instead of sending a technician into the server room.<\/p>\n<h2>Choosing between the APDU9953 and its siblings<\/h2>\n<p>Within this family, the APDU9959EU3 carries the same 21 C13 and 3 C19 outlet set but is rated 16A at 230V, which suits cabinets with a moderate load on a standard circuit. The APDU9959NA3 is rated 20A at 208V and is the choice where the room is wired for that voltage. The APDU9953 is the one to specify when the cabinet&#8217;s load justifies a dedicated 32A, 230V feed, and choosing it at the start for a cabinet that will grow avoids replacing the PDU later.<\/p>\n<h2>Deployment notes<\/h2>\n<p>Before ordering, confirm that the cabinet has a free vertical mounting position in its rear channel, since a ZeroU unit relies on it. Decide in advance which devices will use the three C19 outlets, and have the electrical contractor provide a circuit and protective device rated for 32A at 230V. Judge capacity by the combined draw of the connected equipment rather than by the number of outlets, and do not fill every socket simply because it is there.<\/p>\n<h2>Package Contents<\/h2>\n<ul>\n<li>Installation guide<\/li>\n<li>Rack mounting brackets<\/li>\n<li>Safety guide<\/li>\n<\/ul>\n","protected":false},"excerpt":{"rendered":"<p>A ZeroU switched rack PDU from APC&#8217;s 9000 Switched series, rated 32A at 230V and fitted with 21 C13 and 3 C19 outlets for densely loaded server and network cabinets.<\/p>\n","protected":false},"featured_media":21066,"comment_status":"open","ping_status":"closed","template":"","meta":{"_acf_changed":false},"product_brand":[716],"product_cat":[851],"product_tag":[],"class_list":["post-11045","product","type-product","status-publish","has-post-thumbnail","product_brand-apc","product_cat-power-distribution-pdu","first","onbackorder","sale","taxable","shipping-taxable","purchasable","product-type-simple"],"acf":[],"_links":{"self":[{"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/product\/11045","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/comments?post=11045"}],"version-history":[{"count":1,"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/product\/11045\/revisions"}],"predecessor-version":[{"id":11046,"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/product\/11045\/revisions\/11046"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/media\/21066"}],"wp:attachment":[{"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/media?parent=11045"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/product_brand?post=11045"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/product_cat?post=11045"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/product_tag?post=11045"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}