{"id":11065,"date":"2026-11-17T21:33:16","date_gmt":"2026-11-17T18:33:16","guid":{"rendered":"https:\/\/risys.sa\/?post_type=product&#038;p=11065"},"modified":"2026-11-17T21:33:16","modified_gmt":"2026-11-17T18:33:16","slug":"apc-pdm3516iec-620-power-distribution-module","status":"publish","type":"product","link":"https:\/\/risys.sa\/en\/product\/apc-pdm3516iec-620-power-distribution-module\/","title":{"rendered":"APC PDM3516IEC-620 Power Distribution Module, 620 cm"},"content":{"rendered":"<p>The APC PDM3516IEC-620 is a power distribution module that takes a 400 V three-phase supply, rated at 16 A per line, from the distribution point to an equipment rack over a 620 cm grey cable and presents it at a single IEC 309 16 A outlet. Of the PDM3516IEC-620, PDM3516IEC-680 and PDM3516IEC-740 it is the most compact: the other two share its electrical design but run longer, so this is the one to specify when the rack sits within moderate reach of the source and the route does not justify extra cable. Its ratings are fixed regardless of length: 16 A maximum line current, 16 A maximum current draw, a 16 A breaker rating, 50 Hz operation and an output listed at 230 V and at 400 V three-phase. The assembly carries CE and VDE marks and a 12-month warranty.<\/p>\n<h2>What the APC PDM3516IEC-620 does on site<\/h2>\n<p>A rack PDU spreads power to individual servers and switches, but something has to bring a protected feed to that PDU first. On many projects that link is built on site: an electrician cuts cable to length, terminates it and fits an industrial socket, and the quality of the result depends on the person and the day. The PDM3516IEC-620 replaces that improvised run with a factory-built assembly. The cable, its 16 A protection rating and the IEC 309 outlet arrive as one part, so every rack fed from the same model gets the same termination.<\/p>\n<p>At the rack end, the IEC 309 16 A outlet accepts the matching industrial plug, which in most cabinets belongs to the input lead of a rack PDU. IEC 309 connectors are keyed by current rating and configuration, so a plug made for a different rating will not seat in it. That physical keying matters in shared rooms where contractors from several projects work side by side and labels are not always read.<\/p>\n<p>The 400 V three-phase input lets one module serve a rack whose load is spread over three lines of up to 16 A each, and loading the phases evenly helps keep the upstream panel in balance. The output is listed at both 230 V and 400 V three-phase, so match the downstream rack PDU to whichever of those its outlets are designed for.<\/p>\n<h2>Where the PDM3516IEC-620 fits in Saudi facilities<\/h2>\n<p>A 620 cm lead suits rooms where the distribution source sits at the end of the row or overhead, a moderate distance from the cabinet it feeds. That layout is common in the server rooms of corporate headquarters in Riyadh and Jeddah, in hospital IT rooms that host clinical and records systems, and in the data rooms of universities and government entities that run their own applications.<\/p>\n<p>The 16 A per line rating fits cabinets with a moderate load: network and security racks, CCTV recording servers, access-control controllers and telecom equipment. Security integrators fitting out operations centres for municipalities, shopping malls and industrial sites can standardise on one module for every such cabinet and keep a single spare on the shelf.<\/p>\n<p>In industrial facilities in Jubail, Yanbu and Ras Tanura, where control rooms sit beside motor-control and process panels, a fixed-length factory assembly keeps the IT feed separate from site-built industrial wiring and easy to identify during shutdown inspections.<\/p>\n<h2>PDM3516IEC-620 versus the PDM3516IEC-680 and PDM3516IEC-740<\/h2>\n<p>All three modules share one electrical design: 400 V three-phase input, 16 A per line, a 16 A breaker rating and a single IEC 309 16 A outlet. The difference is reach. The PDM3516IEC-680 adds a longer cable, and the PDM3516IEC-740 goes further again, for racks placed deeper into the row or routed through longer tray paths.<\/p>\n<p>Choose the PDM3516IEC-620 when the measured route, including the rise out of the panel, the path along cable trays and the drop into the cabinet, fits within its length with a little slack. A lead that is too long ends up coiled on top of the rack or under a raised floor, where it obstructs airflow and makes later tracing harder. A lead that is too short invites extension leads and adaptors, which defeat the purpose of a factory-terminated assembly. If the route is marginal, move up to the PDM3516IEC-680 rather than pulling the cable tight.<\/p>\n<h2>Installation notes<\/h2>\n<p>Confirm that the source provides 400 V three-phase at 50 Hz and that upstream protection is sized by the site electrical engineer for a 16 A circuit. Check that the input plug of the equipment it will feed is an IEC 309 16 A type with the same configuration as the outlet. Measure the route on site rather than from drawings, since rack positions and tray routes often shift during fit-out.<\/p>\n<p>The grey finish makes the module easy to pick out from other services in shared trays, and labelling each module at both ends with the rack it feeds saves time during audits. The module is covered by a 12-month warranty, and its CE and VDE marks are the conformity references to list in consultant submittals.<\/p>\n<h2>Package Contents<\/h2>\n<ul>\n<li>Power distribution module<\/li>\n<li>Installation guide<\/li>\n<\/ul>\n","protected":false},"excerpt":{"rendered":"<p>An APC three-phase power distribution module that carries a 400 V, 16 A per line feed to the rack over a 620 cm grey cable, ending in one IEC 309 16 A outlet. It is the shortest of three otherwise identical lengths.<\/p>\n","protected":false},"featured_media":21062,"comment_status":"open","ping_status":"closed","template":"","meta":{"_acf_changed":false},"product_brand":[716],"product_cat":[851],"product_tag":[],"class_list":["post-11065","product","type-product","status-publish","has-post-thumbnail","product_brand-apc","product_cat-power-distribution-pdu","first","onbackorder","sale","taxable","shipping-taxable","purchasable","product-type-simple"],"acf":[],"_links":{"self":[{"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/product\/11065","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/comments?post=11065"}],"version-history":[{"count":1,"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/product\/11065\/revisions"}],"predecessor-version":[{"id":11066,"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/product\/11065\/revisions\/11066"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/media\/21062"}],"wp:attachment":[{"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/media?parent=11065"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/product_brand?post=11065"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/product_cat?post=11065"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/product_tag?post=11065"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}