{"id":11075,"date":"2026-11-17T21:33:14","date_gmt":"2026-11-17T18:33:14","guid":{"rendered":"https:\/\/risys.sa\/?post_type=product&#038;p=11075"},"modified":"2026-11-17T21:33:14","modified_gmt":"2026-11-17T18:33:14","slug":"apc-pdm3516iec-740-power-distribution-module","status":"publish","type":"product","link":"https:\/\/risys.sa\/en\/product\/apc-pdm3516iec-740-power-distribution-module\/","title":{"rendered":"APC PDM3516IEC-740 Power Distribution Module, 740 cm Reach"},"content":{"rendered":"<p>The APC PDM3516IEC-740 gives the longest reach of its three-model group: a 740 cm grey cable that carries a 400 V three-phase supply, rated at 16 A per line, from the distribution source to a single IEC 309 16 A outlet at the cabinet. Where the PDM3516IEC-620 and PDM3516IEC-680 serve racks closer to the source, this module suits cabinets at the far end of a row, routes that climb into overhead trays and cross the room, and layouts that are expected to change. The extra length leaves the electrical ratings untouched: 16 A maximum line current and maximum current draw, a 16 A breaker rating, 50 Hz operation and an output listed at 230 V and at 400 V three-phase. It carries CE and VDE marks and a 12-month warranty.<\/p>\n<h2>What the extra reach of the APC PDM3516IEC-740 solves<\/h2>\n<p>Distance is the usual reason a rack ends up fed by improvised wiring. When the nearest source is across the room, site teams are tempted to join cables or chain extension leads, and each joint becomes an undocumented point of heat and failure. The PDM3516IEC-740 covers that distance in one continuous, factory-terminated run, so the rack receives its 16 A three-phase feed without site-made joints along the way.<\/p>\n<p>It also buys flexibility. Equipment rooms in growing organisations are rearranged more often than planned: a row is extended, a cabinet is moved to make room for cooling, or a new tenant takes a cage. A longer lead lets a rack shift a position or two without replacing its feed, provided the new route still fits within the cable.<\/p>\n<p>At the cabinet, the IEC 309 16 A outlet accepts its matching keyed plug, typically the input of a rack PDU, and the keying stops a plug of another rating from being inserted. The output is listed at 230 V and at 400 V three-phase, so pair it with a rack PDU built for the voltage your devices use.<\/p>\n<h2>Large Saudi sites that need the PDM3516IEC-740<\/h2>\n<p>Bigger rooms produce longer routes. Colocation halls in Riyadh and Dammam, the data centres of telecom operators and cloud providers, and the central IT facilities of major hospitals and universities often place distribution at the room perimeter with racks set well into the floor. In those halls the furthest cabinets are exactly where a 740 cm lead is needed.<\/p>\n<p>Large security operations rooms follow the same logic. Control centres for airports, rail networks, giga-projects and event venues across the Kingdom typically mount video servers, storage and switching in rows that start near the source and stretch away from it. Fitting the end cabinets with the longest module and the nearer ones with shorter siblings keeps every run neat, instead of forcing one compromise length on the whole row.<\/p>\n<p>Temporary and phased installations benefit as well. Site offices and operations rooms on construction megaprojects are reconfigured as phases progress, and a longer feed gives the facilities team room to move cabinets without new cable work.<\/p>\n<h2>Choosing between the PDM3516IEC-740 and its shorter siblings<\/h2>\n<p>The PDM3516IEC-620 and PDM3516IEC-680 match this module&#8217;s 400 V three-phase input, 16 A per line rating and IEC 309 16 A outlet. What the PDM3516IEC-740 adds is length, and length only helps when the route needs it.<\/p>\n<p>Use the PDM3516IEC-740 when a careful measurement, including rises, drops and tray detours, exceeds what the PDM3516IEC-680 can cover, or when a rack is expected to relocate within the room. Where the route is shorter, a nearer length is the better engineering choice, because unused cable has to be stored as a coil that interferes with airflow under floors and above cabinets and makes the circuit harder to identify.<\/p>\n<h2>Routing and installation<\/h2>\n<p>Plan the route through cable trays or overhead ladder before the module arrives, and support the cable along its length rather than letting it hang between trays. Keep it apart from data cabling where the site&#8217;s standards require segregation, and leave a gentle bend where it drops into the cabinet so the outlet is not under strain.<\/p>\n<p>Confirm a 400 V three-phase source at 50 Hz with upstream protection set by the site electrical engineer for a 16 A circuit, and check that the plug of the equipment being fed is an IEC 309 16 A type of matching configuration. Label both ends with the source circuit and the rack it serves. The module comes with a 12-month warranty, and its CE and VDE marks can be listed in the consultant submittal.<\/p>\n<h2>Package Contents<\/h2>\n<ul>\n<li>Power distribution module<\/li>\n<li>Installation guide<\/li>\n<\/ul>\n","protected":false},"excerpt":{"rendered":"<p>The longest of three matching APC power distribution modules: a 740 cm grey cable carrying a 400 V three-phase feed at 16 A per line to one IEC 309 16 A outlet at a distant rack.<\/p>\n","protected":false},"featured_media":21060,"comment_status":"open","ping_status":"closed","template":"","meta":{"_acf_changed":false},"product_brand":[716],"product_cat":[851],"product_tag":[],"class_list":["post-11075","product","type-product","status-publish","has-post-thumbnail","product_brand-apc","product_cat-power-distribution-pdu","first","onbackorder","sale","taxable","shipping-taxable","purchasable","product-type-simple"],"acf":[],"_links":{"self":[{"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/product\/11075","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/comments?post=11075"}],"version-history":[{"count":1,"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/product\/11075\/revisions"}],"predecessor-version":[{"id":11076,"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/product\/11075\/revisions\/11076"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/media\/21060"}],"wp:attachment":[{"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/media?parent=11075"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/product_brand?post=11075"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/product_cat?post=11075"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/product_tag?post=11075"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}