{"id":12145,"date":"2026-11-17T21:32:58","date_gmt":"2026-11-17T18:32:58","guid":{"rendered":"https:\/\/risys.sa\/?post_type=product&#038;p=12145"},"modified":"2026-11-17T21:32:58","modified_gmt":"2026-11-17T18:32:58","slug":"apc-pdm3532iec-380-power-distribution-module","status":"publish","type":"product","link":"https:\/\/risys.sa\/en\/product\/apc-pdm3532iec-380-power-distribution-module\/","title":{"rendered":"APC PDM3532IEC-380 Power Distribution Module, 380 cm Cable"},"content":{"rendered":"<p>The APC PDM3532IEC-380 brings a protected 400 V three-phase supply to a rack that stands further from its power source than a short module can reach. Its 380 cm output cable ends in one IEC 309 32 A connector, and a 32A breaker guards the branch. Of the PDM3532IEC-260, PDM3532IEC-320 and PDM3532IEC-380, it has the longest cable, while the electrical rating stays identical across all three. That makes it the balanced answer for racks deeper in a row or across an aisle: enough reach to cover the distance without relocating the distribution point or adding a joint in the run. It is rated for a maximum line current of 32 A at 50 Hz and comes with its installation guide.<\/p>\n<h2>Why reach matters with the APC PDM3532IEC-380<\/h2>\n<p>A three-phase feed that falls short is not a small problem. The options are to move the rack, move the distribution, or add a connection in the run, and each one costs time or adds a possible point of failure. A cable that reaches cleanly, routed through the tray or floor void and up to the PDU inlet, avoids all three. The PDM3532IEC-380 provides the extra length in the module&#8217;s own cable, so the circuit from breaker to connector stays one continuous assembly.<\/p>\n<p>Surplus has a cost too, if a smaller one: cable coiled under a raised floor gets in the way of the cold-air path. Choose this length when the route genuinely needs it, not as a default for every rack in the room.<\/p>\n<h2>Electrical profile<\/h2>\n<p>Input is 400 V three-phase at 50 Hz, and the output is listed at 230 V and 400 V three-phase, the two voltages a three-phase system offers, phase to neutral and phase to phase. Maximum line current and maximum current draw are both 32 A, matched by the 32A breaker. The single IEC 309 32 A outlet means one module per rack PDU, each rack with its own protection and its own point of isolation.<\/p>\n<h2>Sector fit in the Kingdom<\/h2>\n<p>Large rooms are where the extra reach pays off: the enterprise data halls of banks and insurers, operations centres run by utilities and transport authorities, and the server floors of the giga-project developments, where rows are long and distribution points are fixed early in the build. The PDM3532IEC-380 also suits retrofits in older government and university buildings, where the available three-phase distribution may sit in one corner of the room and racks have to go wherever floor loading and cooling allow.<\/p>\n<h2>Where it sits among PDM3532IEC models<\/h2>\n<p>If the route is shorter, the PDM3532IEC-320 or PDM3532IEC-260 will spare you the surplus cable. The series continues with models from the PDM3532IEC-440 to the PDM3532IEC-980, which also run on a 400 V three-phase supply, so a room can mix lengths without changing its upstream design.<\/p>\n<h2>Installation points<\/h2>\n<p>Size the upstream circuit for 400 V three-phase at 32 A and confirm the facility frequency against the 50 Hz rating. Measure the full route, and choose this model when it needs more than the PDM3532IEC-320 can give but fits within 380 cm with allowance for bends. Keep the rack load below the 32 A limit so there is headroom, leave the IEC 309 connector accessible for isolation, and secure the cable so the connector does not carry its weight. The module is grey, carries CE and VDE marks, and has a 12-month warranty.<\/p>\n<h2>Package Contents<\/h2>\n<ul>\n<li>Installation guide<\/li>\n<\/ul>\n","protected":false},"excerpt":{"rendered":"<p>An APC power distribution module with a 380 cm output cable that takes a protected 400 V three-phase, 32 A feed to racks further from the source through one IEC 309 32 A connector.<\/p>\n","protected":false},"featured_media":21045,"comment_status":"open","ping_status":"closed","template":"","meta":{"_acf_changed":false},"product_brand":[716],"product_cat":[851],"product_tag":[],"class_list":["post-12145","product","type-product","status-publish","has-post-thumbnail","product_brand-apc","product_cat-power-distribution-pdu","first","onbackorder","sale","taxable","shipping-taxable","purchasable","product-type-simple"],"acf":[],"_links":{"self":[{"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/product\/12145","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/comments?post=12145"}],"version-history":[{"count":1,"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/product\/12145\/revisions"}],"predecessor-version":[{"id":12146,"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/product\/12145\/revisions\/12146"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/media\/21045"}],"wp:attachment":[{"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/media?parent=12145"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/product_brand?post=12145"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/product_cat?post=12145"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/product_tag?post=12145"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}