{"id":12150,"date":"2026-11-17T21:32:57","date_gmt":"2026-11-17T18:32:57","guid":{"rendered":"https:\/\/risys.sa\/?post_type=product&#038;p=12150"},"modified":"2026-11-17T21:32:57","modified_gmt":"2026-11-17T18:32:57","slug":"apc-pdm3532iec-440-power-distribution-module","status":"publish","type":"product","link":"https:\/\/risys.sa\/en\/product\/apc-pdm3532iec-440-power-distribution-module\/","title":{"rendered":"APC PDM3532IEC-440 Power Distribution Module, 440 cm"},"content":{"rendered":"<p>The APC PDM3532IEC-440 is a power distribution module that carries a three-phase 400 V circuit, rated at 32 A per line, from its source to a rack over a 440 cm cable and terminates it in a single IEC 309 32 A outlet. Of the three lengths offered here it has the shortest lead, so it suits the rack that stands close to the panel or overhead feed supplying it. A shorter run leaves less surplus cable coiled under the raised floor or on top of the cabinet, keeps airflow paths clear and makes the circuit easier to trace during later maintenance. The electrical rating does not change with length: 32 A maximum line current, a 32 A breaker, a 50 Hz rating and an output listed at 230 V and at 400 V three-phase. The cable assembly is grey and carries CE and VDE marks.<\/p>\n<h2>How the APC PDM3532IEC-440 works between panel and rack<\/h2>\n<p>Every rack that holds servers, storage or core switching needs its own protected circuit. The usual route is an electrician pulling cable and fitting an industrial socket on site, a job whose result differs a little each time it is done. This module delivers that circuit as one finished assembly, with breaker, cable and outlet in a single part, so the result is identical from rack to rack and quick to replace if a row is rearranged.<\/p>\n<p>The 32 A breaker protects the run itself. At the rack end, the IEC 309 32 A outlet receives the matching industrial plug of the equipment it feeds, which in most cabinets is the input plug of a rack PDU that then spreads power to individual devices. IEC 309 connectors are keyed by rating and configuration, so a plug built for a different current or pin arrangement will not go in by mistake.<\/p>\n<p>Because the supply is three-phase at 400 V, the rack draws on three lines of up to 32 A each rather than a single one, which gives it far more headroom than a single-phase feed at the same current. Spreading the loads across the phases also keeps the upstream supply balanced, something facility engineers watch closely in rooms with dozens of racks.<\/p>\n<h2>Where it fits in Saudi facilities<\/h2>\n<p>The short lead is at its best in compact rooms where the distribution panel stands at the end of a short row or directly behind the cabinets. That describes many of the server rooms inside bank head offices in Riyadh, the equipment rooms of hospitals running their clinical and records systems, and the IT rooms of universities and government entities that host their own applications.<\/p>\n<p>Telecom operators and internet service providers follow the same pattern in switching and aggregation rooms, where racks are dense and every metre of slack cable competes with fibre trays for space. In industrial plants in Jubail and Yanbu, a control-room rack with a nearby panel benefits from a short, tidy run that stays clear of other services.<\/p>\n<h2>Choosing the PDM3532IEC-440 against its siblings<\/h2>\n<p>The PDM3532IEC-500 and PDM3532IEC-560 are electrically identical to this module and use the same type of outlet; what they add is a longer cable for racks set further from the source. That turns the decision into a matter of distance rather than capacity.<\/p>\n<p>The right choice is the shortest model that reaches the rack without strain once vertical rises, bends and the path through cable trays are counted. Picking the PDM3532IEC-440 when the route allows it avoids a heavy coil of spare cable, which takes space and can obstruct cooling. If the measured route comes out longer than this lead, step up to one of the longer siblings rather than extending the circuit with adaptors or improvised joints.<\/p>\n<h2>Installation notes for the APC PDM3532IEC-440<\/h2>\n<p>The module needs a 400 V three-phase source with upstream protection sized by the site electrical engineer, and the plug on the equipment it feeds must be an IEC 309 32 A type of matching configuration. Its rated frequency is 50 Hz, so check that rating against the supply frequency of the panel that will feed it before ordering.<\/p>\n<p>Measure the actual cable path from the source to the rack position before choosing, including the rise into the cabinet and any detours around trays. An installation guide ships in the box, and the module is covered by a 12-month warranty. For consultant submittals on government and semi-government projects, the CE and VDE marks are the conformity references to list.<\/p>\n<h2>Package Contents<\/h2>\n<ul>\n<li>Installation guide<\/li>\n<\/ul>\n","protected":false},"excerpt":{"rendered":"<p>An APC three-phase power distribution module that brings a protected 400 V, 32 A circuit to the rack over a 440 cm cable, ending in one IEC 309 32 A outlet.<\/p>\n","protected":false},"featured_media":21044,"comment_status":"open","ping_status":"closed","template":"","meta":{"_acf_changed":false},"product_brand":[716],"product_cat":[851],"product_tag":[],"class_list":["post-12150","product","type-product","status-publish","has-post-thumbnail","product_brand-apc","product_cat-power-distribution-pdu","first","onbackorder","sale","taxable","shipping-taxable","purchasable","product-type-simple"],"acf":[],"_links":{"self":[{"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/product\/12150","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/comments?post=12150"}],"version-history":[{"count":1,"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/product\/12150\/revisions"}],"predecessor-version":[{"id":12151,"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/product\/12150\/revisions\/12151"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/media\/21044"}],"wp:attachment":[{"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/media?parent=12150"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/product_brand?post=12150"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/product_cat?post=12150"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/product_tag?post=12150"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}