{"id":12155,"date":"2026-11-17T21:32:56","date_gmt":"2026-11-17T18:32:56","guid":{"rendered":"https:\/\/risys.sa\/?post_type=product&#038;p=12155"},"modified":"2026-11-17T21:32:56","modified_gmt":"2026-11-17T18:32:56","slug":"apc-pdm3532iec-500-power-distribution-module","status":"publish","type":"product","link":"https:\/\/risys.sa\/en\/product\/apc-pdm3532iec-500-power-distribution-module\/","title":{"rendered":"APC PDM3532IEC-500 Power Distribution Module, 500 cm"},"content":{"rendered":"<p>When a rack stands a few positions down the row from its distribution panel, the cable has to cover the extra distance without leaving a heavy coil behind. The APC PDM3532IEC-500 answers that case with a 500 cm lead, which places it in the middle of the three lengths offered here. It is a three-phase power distribution module for a 400 V supply, rated for a maximum line current and a maximum current draw of 32 A and protected by a 32 A breaker, and it hands that circuit to the rack through one IEC 309 32 A outlet. Output is listed at 230 V and at 400 V three-phase on a 50 Hz rating. In practice it is the length to reach for when the shorter lead falls just short and the longest would leave cable to spare. The assembly is grey and marked CE and VDE.<\/p>\n<h2>What the APC PDM3532IEC-500 does on site<\/h2>\n<p>Think of the module as a prefabricated branch circuit. Instead of a separate breaker, a length of site-run cable and an industrial socket fitted by hand, the protection, the conductor run and the termination arrive as one product. For a contractor fitting out a data hall, that turns a craft job into a repeatable one: each rack gets the same circuit, installed the same way and documented under the same model number.<\/p>\n<p>The rack end carries a single IEC 309 32 A outlet. Whatever it feeds, usually a rack PDU, must present a matching IEC 309 32 A plug. Because these industrial connectors are keyed, a mismatched plug cannot be forced in, which protects equipment during moves and additions when several teams are working in the same room.<\/p>\n<p>On the supply side the module works at 400 V across three phases, with each line carrying up to 32 A. A three-phase feed lets one rack support a dense load such as virtualisation hosts and storage arrays. The 32 A breaker is the boundary: the combined draw of everything behind the module has to stay within it, and planning loads phase by phase keeps each line inside that rating.<\/p>\n<h2>Saudi sites that call for the 500 cm lead<\/h2>\n<p>Mid-sized data halls are where this length earns its place: colocation suites in Riyadh and Dammam, the primary and recovery data centres of insurers and finance companies, and the computer rooms of large hospital groups, where racks stand in rows of moderate length fed from a single panel. In these rooms the second or third cabinet down from the panel is often out of reach of the shortest lead.<\/p>\n<p>The same holds for telecom and broadcast facilities, whose equipment rooms grow rack by rack, and for municipal and ministry sites consolidating servers from several buildings into one room. For contractors on giga-project and new-city infrastructure, a standard mid-length module also simplifies stocking, since one model can serve many positions along a row while the shorter and longer lengths are kept for its ends.<\/p>\n<h2>PDM3532IEC-500 among the PDM3532IEC lengths<\/h2>\n<p>Electrically, the PDM3532IEC-440 and PDM3532IEC-560 are the same module as this one; only the cable differs, with the PDM3532IEC-440 a little shorter and the PDM3532IEC-560 a little longer. The comparison is therefore about distance, not capacity.<\/p>\n<p>Selecting by measurement rather than by habit pays off. Too short, and the module will only reach by being pulled tight over tray edges; too long, and the spare cable ends up coiled where it blocks airflow and gets in the way of the next installation. When a measured route lands between the shorter and the longer option, the PDM3532IEC-500 is the balanced choice.<\/p>\n<h2>Before you install the APC PDM3532IEC-500<\/h2>\n<p>Confirm three things on the drawings first. The source must be a 400 V three-phase supply, protected upstream as the electrical engineer specifies. The equipment at the rack must take an IEC 309 32 A plug of matching configuration. And the module&#8217;s 50 Hz rating should be checked against the frequency of the supply that will feed it.<\/p>\n<p>Then walk the route with a tape measure: from the panel, along the tray or under the floor, up into the cabinet and across to the point where the rack PDU plugs in. An installation guide is included with the module, the warranty runs for 12 months, and the CE and VDE marks can be cited in consultant submittals.<\/p>\n<h2>Package Contents<\/h2>\n<ul>\n<li>Installation guide<\/li>\n<\/ul>\n","protected":false},"excerpt":{"rendered":"<p>A mid-length APC power distribution module: a 500 cm cable carrying a 400 V three-phase, 32 A circuit to the rack, terminated in one IEC 309 32 A outlet.<\/p>\n","protected":false},"featured_media":21043,"comment_status":"open","ping_status":"closed","template":"","meta":{"_acf_changed":false},"product_brand":[716],"product_cat":[851],"product_tag":[],"class_list":["post-12155","product","type-product","status-publish","has-post-thumbnail","product_brand-apc","product_cat-power-distribution-pdu","first","onbackorder","sale","taxable","shipping-taxable","purchasable","product-type-simple"],"acf":[],"_links":{"self":[{"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/product\/12155","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/comments?post=12155"}],"version-history":[{"count":1,"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/product\/12155\/revisions"}],"predecessor-version":[{"id":12156,"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/product\/12155\/revisions\/12156"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/media\/21043"}],"wp:attachment":[{"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/media?parent=12155"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/product_brand?post=12155"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/product_cat?post=12155"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/product_tag?post=12155"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}