{"id":12165,"date":"2026-11-17T21:32:55","date_gmt":"2026-11-17T18:32:55","guid":{"rendered":"https:\/\/risys.sa\/?post_type=product&#038;p=12165"},"modified":"2026-11-17T21:32:55","modified_gmt":"2026-11-17T18:32:55","slug":"apc-pdm3532iec-920-power-distribution-module","status":"publish","type":"product","link":"https:\/\/risys.sa\/en\/product\/apc-pdm3532iec-920-power-distribution-module\/","title":{"rendered":"APC PDM3532IEC-920 Power Distribution Module, 920 cm"},"content":{"rendered":"<p>The APC PDM3532IEC-920 is a three-phase power distribution module built for the rack that stands a long way from its power source. It takes a 400 V three-phase supply through a 32 A breaker and delivers it over 920 cm of grey cable to a single IEC 309 32 A outlet at the rack end. That reach is the reason to choose it: in a hall where the distribution panel sits at the perimeter and the cabinets fill the middle of the floor, a factory-made lead of this length crosses the distance in one piece, with no field joints and no improvised extensions. Electrically it matches the shorter modules in the series, with a 32 A maximum line current, a 50 Hz rating and an output listed at 230 V and at 400 V three-phase, so the buying decision comes down to route length and price. The assembly carries CE and VDE marks.<\/p>\n<h2>Planning a long run with the APC PDM3532IEC-920<\/h2>\n<p>A long cable changes how the circuit is planned, not what it delivers. Over 920 cm the route usually leaves the panel, climbs into an overhead tray or drops under a raised floor, follows the row, and then rises or falls again into the cabinet. Every one of those turns consumes length, so measure the real path rather than the straight-line distance between panel and rack. When the measured route lands comfortably inside the lead, the module arrives as a finished circuit: breaker at one end, outlet at the other, nothing to terminate on site.<\/p>\n<p>Because the breaker, cable and outlet come as one assembly, every rack along a long row gets the same circuit built the same way. That consistency matters to the people who maintain the room. A damaged lead is replaced as a whole part instead of being traced and repaired along a crowded tray, and the circuit schedule stays simple: one module, one rack, one protected 32 A feed.<\/p>\n<h2>What the rack receives at the far end<\/h2>\n<p>The IEC 309 32 A outlet is an industrial connector keyed by current rating and pin arrangement. It accepts only the matching IEC 309 32 A plug, which in a typical cabinet is the input of a rack PDU that then distributes power to servers, storage and switching. A plug made for a different rating or configuration cannot be pushed in by mistake, which keeps equipment from being connected to the wrong supply.<\/p>\n<p>With three lines of up to 32 A each on a 400 V three-phase supply, the rack has far more capacity available than a single-phase feed at the same current. Spreading the rack loads across the three phases also keeps the upstream panel balanced, which matters in rooms where many long circuits leave the same board.<\/p>\n<h2>Saudi facilities that need the extra reach<\/h2>\n<p>Long leads earn their place in large rooms. Colocation and cloud data halls in Riyadh, Jeddah and Dammam often place distribution panels along the walls and run circuits to cages and rows set deep in the white space. Bank and government data centres that keep primary and disaster-recovery rooms in separate wings face similar distances when a new row is added far from the existing panels. Telecom operators running core and aggregation sites, and petrochemical and utility operators with server rows inside control buildings in Jubail and Ras Tanura, regularly need a circuit that crosses most of a room. In each case a single continuous module is easier to document and inspect than a shorter lead extended in the field.<\/p>\n<h2>PDM3532IEC-920 or a sibling<\/h2>\n<p>The PDM3532IEC-980 shares this module&#8217;s electrical design and adds a little more cable; take it when the measured route runs slightly past what the PDM3532IEC-920 can reach. Further down the series, the PDM3532IEC-560 and the shorter modules are meant for racks close to their source and will not reach a rack across the hall. The opposite mistake costs space: using this module for a nearby rack leaves a heavy coil of surplus cable to store above the cabinet or under the floor, where it obstructs airflow. The rule is simple: pick the shortest lead that completes the measured route without strain.<\/p>\n<h2>Installation notes for the APC PDM3532IEC-920<\/h2>\n<p>Feed the module from a 400 V three-phase source whose upstream protection has been sized by the site electrical engineer, and confirm that the equipment at the rack end has a matching IEC 309 32 A input plug. The module is rated at 50 Hz, so check that rating against the frequency of the supply that will feed it before placing the order. Support the cable along its whole route in trays or under-floor channels so its weight never hangs from the outlet, keep the bend gentle where it enters the cabinet, and label both ends against the circuit schedule. An installation guide is included, and the module is covered by a 12-month warranty.<\/p>\n<h2>Package Contents<\/h2>\n<ul>\n<li>Installation guide<\/li>\n<\/ul>\n","protected":false},"excerpt":{"rendered":"<p>A three-phase APC power distribution module that carries a protected 400 V, 32 A circuit across 920 cm of cable to a distant rack, ending in one IEC 309 32 A outlet.<\/p>\n","protected":false},"featured_media":21041,"comment_status":"open","ping_status":"closed","template":"","meta":{"_acf_changed":false},"product_brand":[716],"product_cat":[851],"product_tag":[],"class_list":["post-12165","product","type-product","status-publish","has-post-thumbnail","product_brand-apc","product_cat-power-distribution-pdu","first","onbackorder","sale","taxable","shipping-taxable","purchasable","product-type-simple"],"acf":[],"_links":{"self":[{"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/product\/12165","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/comments?post=12165"}],"version-history":[{"count":1,"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/product\/12165\/revisions"}],"predecessor-version":[{"id":12166,"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/product\/12165\/revisions\/12166"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/media\/21041"}],"wp:attachment":[{"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/media?parent=12165"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/product_brand?post=12165"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/product_cat?post=12165"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/product_tag?post=12165"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}