{"id":12245,"date":"2026-11-17T21:32:41","date_gmt":"2026-11-17T18:32:41","guid":{"rendered":"https:\/\/risys.sa\/?post_type=product&#038;p=12245"},"modified":"2026-11-18T20:56:12","modified_gmt":"2026-11-18T17:56:12","slug":"apc-e3sups15khb-three-phase-ups","status":"publish","type":"product","link":"https:\/\/risys.sa\/en\/product\/apc-e3sups15khb-three-phase-ups\/","title":{"rendered":"APC E3SUPS15KHB 15 kVA Three-Phase UPS Without Batteries"},"content":{"rendered":"<p>APC E3SUPS15KHB is a 15 kVA three-phase UPS with a 15 kW output rating, supplied as a power unit without batteries. Its battery slots arrive empty, which makes it the balanced choice in the family for buyers who want the middle capacity step but intend to source and fit VRLA battery strings themselves, on their own schedule and budget. The unit is built around a 240 V battery bus, so the strings you fit must match that voltage and the VRLA type it is designed for. It sits one step above the E3SUPS10KHB2, which is rated 10 kW \/ 10 kVA. It sits below the E3SUPS20KHB, which is rated 20 kVA, so it covers a mid-sized technical room without paying for capacity the load will not use. Specify it when the project already has a battery supplier, when batteries are budgeted under a separate line, or when the cabinet will be installed before the site is ready for commissioning.<\/p>\n<h2>APC E3SUPS15KHB in practice<\/h2>\n<p>As delivered, this unit cannot carry a load through an outage: it needs battery strings fitted before it provides backup. That is the trade-off behind its place in the range. The purchase covers the power electronics alone, and the battery decision stays with you, from how many strings to which supplier and when they go in. Make that decision alongside the UPS order, so the batteries arrive for commissioning and the unit is not left waiting for them.<\/p>\n<p>Load sizing works against two figures: 15 kVA apparent power and 15 kW real power. With both ratings equal, the full capacity is usable in watts, and a load list of servers, switches, recorders and control panels can be checked directly against 15 kW with a margin left for growth.<\/p>\n<h2>Saudi applications for the 15 kVA step<\/h2>\n<p>This rating fits facilities whose technical load has outgrown a small closet: the nursing-station network and nurse-call equipment of a hospital wing, the server room of a school or college building, the monitoring centre of a residential compound, a warehouse with its inventory servers and network, or a government branch office with IT and security systems on one board. On projects where the electrical contractor procures batteries under a separate package, a battery-less unit fits that split cleanly. The dust filter in the box is worth keeping in service in plant rooms where fine dust builds up.<\/p>\n<h2>E3SUPS15KHB versus its siblings<\/h2>\n<p>The closest sibling is the E3SUPS15KHB2, which shares this capacity step but arrives with internal battery strings already fitted; choose it if you want backup from day one without a separate battery order. For smaller rooms, the E3SUPS10KHB2 is rated 10 kW \/ 10 kVA. For heavier loads, the E3SUPS20KHB is rated 20 kVA. The E3SUPS30KHB is rated 30 kW \/ 30 kVA. Pick the E3SUPS15KHB when 15 kW covers your load and you want full control over the battery side.<\/p>\n<h2>Deployment notes<\/h2>\n<p>Match every battery string to the 240 V battery bus and the VRLA type, and fit identical strings rather than mixing ages or capacities. Leave clear access to the battery slots and the dust filter for maintenance, and keep the installation guide in the site file. Size the upstream protection and cabling for a 15 kVA three-phase load according to local electrical practice, and have a qualified technician carry out the connection and the battery installation.<\/p>\n<h2>Package Contents<\/h2>\n<ul>\n<li>Dust filter<\/li>\n<li>Installation guide<\/li>\n<\/ul>\n","protected":false},"excerpt":{"rendered":"<p>A 15 kVA, 15 kW APC three-phase UPS supplied without batteries: its battery slots arrive empty, ready for VRLA strings on a 240 V battery bus.<\/p>\n","protected":false},"featured_media":21025,"comment_status":"open","ping_status":"closed","template":"","meta":{"_acf_changed":false},"product_brand":[716],"product_cat":[845,706],"product_tag":[],"class_list":["post-12245","product","type-product","status-publish","has-post-thumbnail","product_brand-apc","product_cat-three-phase-ups","product_cat-ups-backup-power","first","onbackorder","sale","taxable","shipping-taxable","purchasable","product-type-simple"],"acf":[],"_links":{"self":[{"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/product\/12245","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/comments?post=12245"}],"version-history":[{"count":1,"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/product\/12245\/revisions"}],"predecessor-version":[{"id":12246,"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/product\/12245\/revisions\/12246"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/media\/21025"}],"wp:attachment":[{"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/media?parent=12245"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/product_brand?post=12245"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/product_cat?post=12245"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/product_tag?post=12245"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}