{"id":12310,"date":"2026-11-17T21:32:37","date_gmt":"2026-11-17T18:32:37","guid":{"rendered":"https:\/\/risys.sa\/?post_type=product&#038;p=12310"},"modified":"2026-11-17T21:32:37","modified_gmt":"2026-11-17T18:32:37","slug":"apc-gvsopt006-ups-parallel-communications-kit","status":"publish","type":"product","link":"https:\/\/risys.sa\/en\/product\/apc-gvsopt006-ups-parallel-communications-kit\/","title":{"rendered":"APC GVSOPT006 UPS Parallel Communications Kit, 25m PBUS"},"content":{"rendered":"<p>The APC GVSOPT006 is the parallel communications kit for UPS parallel systems: it comes with PBUS cables 25m long and 2 AUX contacts, the links that paralleled UPS units use to coordinate as one system. In APC&#8217;s accessories range it is the balanced, per-link choice. Rather than one large package sized for the biggest possible system, you buy kits in step with the number of UPS units: 1 kit for 2 UPS units, 2 kits for 3 units and 3 kits for 4 units. That scaling keeps the cost tied to the system you are actually building and turns later expansion into the purchase of one more kit. The 25m PBUS length also gives room to spread the units out within the UPS room or place them in separate cabinets.<\/p>\n<h2>How the APC GVSOPT006 works in a parallel system<\/h2>\n<p>Paralleling UPS units is only half electrical; the other half is communication. Each unit has to know what the others are doing so the load is shared and transfers are coordinated. The PBUS cables in the GVSOPT006 carry that link between units, and the 2 AUX contacts give the installer additional signalling points for the parallel arrangement. The kit is counted per link rather than per unit, so the rule is the number of units minus one: a 2-unit system needs 1 kit, a 3-unit system needs 2 kits and a 4-unit system needs 3 kits.<\/p>\n<h2>Saudi use cases<\/h2>\n<p>Parallel UPS systems are chosen where one unit is not enough, or where a single failure must not drop the load: the critical-care and IT backbone of a Riyadh hospital, a ministry data hall, an airport or seaport operations centre in Jeddah or Dammam, or the central control room of a petrochemical plant in Jubail. On these sites the UPS room often grows in phases as budgets are approved. Because the GVSOPT006 is bought per link, a site that starts with two units can add a third later with one more kit, and the 25m PBUS cables give the electrical contractor freedom over where the new unit stands.<\/p>\n<h2>GVSOPT006 compared with other APC accessories<\/h2>\n<p>This kit is easy to confuse with other parts in the same family. The E3SOPT006 is a maintenance bypass panel for parallel Easy UPS 3S systems; it handles the power path during service, not the communication between units. The AP9640 and AP9641 network management cards connect a UPS to your IT network for monitoring, which is a different job from the unit-to-unit PBUS link. The GVSOPT026 is a protection kit for the UPS enclosure. If your design calls for UPS units running in parallel, the GVSOPT006 is the part that links them.<\/p>\n<h2>Deployment notes<\/h2>\n<p>Count your UPS units first and order kits to match: 1 kit for 2 units, 2 kits for 3 units, 3 kits for 4 units. Plan the PBUS cable route between units before the cabinets are fixed, keeping it within the 25m cable length and away from power cabling where possible, and label both ends of each cable so maintenance staff can trace the link later. Have the parallel configuration and the AUX contact wiring commissioned by a qualified UPS technician, and confirm before ordering that your UPS model is designed for parallel operation.<\/p>\n<h2>Package Contents<\/h2>\n<ul>\n<li>PBUS cables (25m)<\/li>\n<li>AUX contacts \u00d7 2<\/li>\n<\/ul>\n","protected":false},"excerpt":{"rendered":"<p>A parallel communications kit for UPS parallel systems with 25m PBUS cables and 2 AUX contacts, ordered by system size: 1 kit for 2 UPS units, 2 kits for 3, and 3 kits for 4.<\/p>\n","protected":false},"featured_media":21020,"comment_status":"open","ping_status":"closed","template":"","meta":{"_acf_changed":false},"product_brand":[716],"product_cat":[706,849],"product_tag":[],"class_list":["post-12310","product","type-product","status-publish","has-post-thumbnail","product_brand-apc","product_cat-ups-backup-power","product_cat-ups-accessories","first","onbackorder","sale","taxable","shipping-taxable","purchasable","product-type-simple"],"acf":[],"_links":{"self":[{"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/product\/12310","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/comments?post=12310"}],"version-history":[{"count":1,"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/product\/12310\/revisions"}],"predecessor-version":[{"id":12311,"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/product\/12310\/revisions\/12311"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/media\/21020"}],"wp:attachment":[{"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/media?parent=12310"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/product_brand?post=12310"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/product_cat?post=12310"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/product_tag?post=12310"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}