{"id":14092,"date":"2026-11-17T21:32:31","date_gmt":"2026-11-17T18:32:31","guid":{"rendered":"https:\/\/risys.sa\/?post_type=product&#038;p=14092"},"modified":"2026-11-17T21:32:31","modified_gmt":"2026-11-17T18:32:31","slug":"apc-pdm3516iec-1040-power-distribution-module","status":"publish","type":"product","link":"https:\/\/risys.sa\/en\/product\/apc-pdm3516iec-1040-power-distribution-module\/","title":{"rendered":"APC PDM3516IEC-1040 Power Distribution Module"},"content":{"rendered":"<p>APC PDM3516IEC-1040 is a power distribution module for projects where the cable route deserves as much attention as the electrical rating. Its 1040 cm output cable gives facilities teams a defined length to assess against the path between distribution equipment and the intended connection. The module combines a 16 A rating with a single IEC 309 outlet, circuit monitoring and automatic identification by the Modular PDU. For a buyer balancing coverage with the needs of a particular installation, the useful starting point is the actual route: where the cable travels, where it terminates and how technicians will reach it later. This model suits a selection process built around those practical requirements rather than the model name alone.<\/p>\n<h2>APC PDM3516IEC-1040 in an electrical distribution plan<\/h2>\n<p>The input is 400 V three-phase at 50 Hz. Maximum current draw is 16 A, and maximum line current is also 16 A. These ratings give the electrical contractor concrete limits to compare with the proposed supply and connected load. Use the planned operating load as the basis for selection, with the installation designer assessing the complete circuit. A cable that reaches the destination still needs the correct electrical arrangement at its source and at the equipment connection.<\/p>\n<p>The single IEC 309 16 A outlet makes the termination a key purchasing detail. Check the mating connection before ordering and mark that interface on the installation drawing. This is particularly useful when procurement, electrical installation and equipment commissioning sit with different contractors. A shared description of the connection reduces the risk of a module arriving at site with a destination that has not been prepared for it.<\/p>\n<h2>Cable reach and service access<\/h2>\n<p>The 1040 cm output cable should be assessed along the intended path, including changes in direction and the approach to the connection point. A direct measurement across a room can overlook the distance introduced by an organised cable route. Plan where the run will be supported and how access to nearby equipment will be maintained. The value of this cable length depends on how closely it matches the installed path, so establish that path before finalising the purchase.<\/p>\n<p>The grey module measures 15.2 cm high, 43.2 cm wide and 40.6 cm deep, with a net weight of 4.29 kg. Check these dimensions against the available space and the approach needed for installation. Include the module in the physical layout rather than considering only the cable destination. Leave the installer a clear understanding of where the body sits and where the output cable continues into the distribution route.<\/p>\n<h2>Monitoring during operation<\/h2>\n<p>Circuit monitoring supports the operational review of the distribution circuit, while automatic module detection allows the Modular PDU to identify the module. For facilities teams, these functions make the module relevant to ongoing operation as well as initial connection. Include circuit identification in the handover documents so the operations team can relate the installed module to the equipment it serves. The module also incorporates one three-pole breaker, which should be represented in the circuit documentation.<\/p>\n<h2>Choosing within the APC family<\/h2>\n<p>Review PDM3516IEC-260 and PDM3516IEC-320 alongside this model when specifying an APC distribution project. Use the required cable route and connection arrangement to decide which exact reference belongs on the order. The broader family also contains AP9559 and AP9565; keep those model references distinct when matching a bill of materials to the intended distribution design. A similar brand or family description is not a substitute for matching the selected module to its assigned circuit.<\/p>\n<h2>Saudi project deployment and handover<\/h2>\n<p>In a Saudi data room, commercial facilities project or operations centre, evaluate this module where the distribution design calls for its electrical input and outlet. Have the project electrician confirm the supply before installation, and coordinate the cable path with the team responsible for equipment placement. The installation guide supports that preparation, while the 12-month warranty is relevant to procurement handover. Record the exact model, cable destination and circuit association so maintenance staff can identify the installed module when the room layout or connected equipment changes.<\/p>\n<h2>Package Contents<\/h2>\n<ul>\n<li>Installation guide<\/li>\n<\/ul>\n","protected":false},"excerpt":{"rendered":"<p>Power distribution module with a 1040 cm output cable, 16 A current rating and a single IEC 309 outlet. Circuit monitoring and automatic module detection support integration with a Modular PDU.<\/p>\n","protected":false},"featured_media":21012,"comment_status":"open","ping_status":"closed","template":"","meta":{"_acf_changed":false},"product_brand":[716],"product_cat":[851],"product_tag":[],"class_list":["post-14092","product","type-product","status-publish","has-post-thumbnail","product_brand-apc","product_cat-power-distribution-pdu","first","onbackorder","sale","taxable","shipping-taxable","purchasable","product-type-simple"],"acf":[],"_links":{"self":[{"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/product\/14092","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/comments?post=14092"}],"version-history":[{"count":1,"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/product\/14092\/revisions"}],"predecessor-version":[{"id":14093,"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/product\/14092\/revisions\/14093"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/media\/21012"}],"wp:attachment":[{"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/media?parent=14092"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/product_brand?post=14092"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/product_cat?post=14092"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/product_tag?post=14092"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}