{"id":14340,"date":"2026-11-17T21:32:29","date_gmt":"2026-11-17T18:32:29","guid":{"rendered":"https:\/\/risys.sa\/?post_type=product&#038;p=14340"},"modified":"2026-11-17T21:32:29","modified_gmt":"2026-11-17T18:32:29","slug":"apc-epdu1132b-basic-rack-pdu","status":"publish","type":"product","link":"https:\/\/risys.sa\/en\/product\/apc-epdu1132b-basic-rack-pdu\/","title":{"rendered":"APC EPDU1132B Basic Rack PDU 0U"},"content":{"rendered":"<p>APC EPDU1132B is a Basic Rack PDU for cabinets that need a defined electrical distribution point and a vertical mounting arrangement. Its 7360 VA load capacity, single-phase input and mixed IEC outlets make the purchasing decision practical: match the cabinet supply, equipment leads and planned load before installation. This model concentrates on basic distribution within the family, while the metered versions address a different operating requirement. For a facilities manager equipping a server room, branch communications cabinet or security equipment rack, the appeal is a straightforward power layout that leaves the rack mounting positions available for equipment. Select it around the electrical design of the cabinet rather than the outlet count alone.<\/p>\n<h2>APC EPDU1132B for basic rack distribution<\/h2>\n<p>The input current limit and maximum current draw are 32 A. Input voltage options are 200 V, 208 V and 230 V, with a specified output voltage of 230 V and frequency of 50\/60 Hz. The input connection is IEC 60309 32 A 2P + E. These details belong in the handover between the IT team and the electrical contractor: the upstream connection must suit the unit, and the planned equipment demand must remain within the electrical limits. Treat the 7360 VA figure as a capacity boundary when preparing the cabinet load schedule.<\/p>\n<h2>Match the outlets to the equipment<\/h2>\n<p>The outlet arrangement comprises 20 IEC 60320 C13 connections and 4 IEC 60320 C19 connections. A mixed cabinet can therefore be planned around the actual connector needs of its devices rather than assuming every power lead ends in the same fitting. Before ordering, identify which equipment will use each outlet type and check the corresponding leads. Having an unused outlet does not establish that additional load is available. Review the connected demand as well as the physical connection plan whenever equipment is added or moved between cabinets.<\/p>\n<h2>Keep the cabinet layout workable<\/h2>\n<p>Vertical side mounting and the 0U format place distribution beside the equipment area. The body measures 1175 mm high, 62 mm wide and 44.4 mm deep, with a net weight of 3.58 kg. Use those dimensions to check the available side space, cable access and clearance before assigning a mounting position. The supply cable is 2.99 m long. Measure its intended route from the cabinet to the supply connection, allowing for the actual path through cable management rather than relying on a straight-line distance across the room.<\/p>\n<h2>Where it fits in Saudi facilities<\/h2>\n<p>In an office communications room, this unit can provide a common distribution location for compatible rack equipment. In a retail branch or logistics facility, it suits planning where the cabinet is maintained as a local installation and the purchasing brief calls for basic distribution. A security operations team can assess it for its equipment rack by checking connector types and the combined electrical demand of the installed devices. These are cabinet applications: the deciding factors remain the supply connection, mounting clearance and equipment load, regardless of the business sector using the room.<\/p>\n<h2>Choose between the family members<\/h2>\n<p>EPDU1132M is the named metered alternative when remote monitoring is part of the operating brief. EPDU1216M is another metered option to assess when the site&#8217;s supply design calls for a different electrical arrangement. EPDU1132B belongs on the shortlist when the requirement is basic rack power distribution. Settle that operational requirement before comparing individual connections: a cabinet that needs remote oversight should be specified around that need, while a basic installation can be assessed directly against its electrical and mechanical fit.<\/p>\n<h2>Installation environment and handover<\/h2>\n<p>The operating temperature range is 0 to 45 \u00b0C, and operating relative humidity is 5 to 95%. Check the conditions at the intended cabinet position, especially where distribution sits beside equipment exhaust paths. The storage temperature range is -25 to 65 \u00b0C, which should be considered separately from operating conditions during project staging. The warranty period is 12 months. At handover, retain the cabinet load schedule, identify the supply connection and leave the outlet allocation clear for subsequent service work. This makes future equipment changes easier to assess against the same installation limits.<\/p>\n<h2>Package Contents<\/h2>\n<ul>\n<li>Installation guide<\/li>\n<li>Toolless mounting kit<\/li>\n<li>Vertical mounting brackets<\/li>\n<\/ul>\n","protected":false},"excerpt":{"rendered":"<p>Basic vertical rack distribution rated at 7360 VA with 20 C13 and 4 C19 outlets. A 32 A IEC input and 2.99 m cable support cabinet power planning.<\/p>\n","protected":false},"featured_media":21009,"comment_status":"open","ping_status":"closed","template":"","meta":{"_acf_changed":false},"product_brand":[716],"product_cat":[851],"product_tag":[],"class_list":["post-14340","product","type-product","status-publish","has-post-thumbnail","product_brand-apc","product_cat-power-distribution-pdu","first","onbackorder","sale","taxable","shipping-taxable","purchasable","product-type-simple"],"acf":[],"_links":{"self":[{"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/product\/14340","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/comments?post=14340"}],"version-history":[{"count":1,"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/product\/14340\/revisions"}],"predecessor-version":[{"id":14341,"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/product\/14340\/revisions\/14341"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/media\/21009"}],"wp:attachment":[{"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/media?parent=14340"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/product_brand?post=14340"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/product_cat?post=14340"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/product_tag?post=14340"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}