{"id":18529,"date":"2026-11-17T21:32:12","date_gmt":"2026-11-17T18:32:12","guid":{"rendered":"https:\/\/risys.sa\/?post_type=product&#038;p=18529"},"modified":"2026-11-17T21:32:12","modified_gmt":"2026-11-17T18:32:12","slug":"apc-ap8712s-locking-power-cord-kit","status":"publish","type":"product","link":"https:\/\/risys.sa\/en\/product\/apc-ap8712s-locking-power-cord-kit\/","title":{"rendered":"APC AP8712S Locking C19 to C20 Power Cord Kit, 0.6 m"},"content":{"rendered":"<p>APC AP8712S is a kit of six locking power cords, each 0.6 m long, made for the shortest high-current runs in a rack: from a C19 outlet on a PDU or UPS to the C20 inlet of a server, storage shelf or network chassis mounted close by. Within this cord family it sits at the compact end of a balanced range, with enough slack to reach a device near its outlet but without the surplus loop that longer cords leave coiled behind equipment. Each cord is rated for 16 A, uses IEC 60320 C20 and C19 connectors, and the locking design holds the connection in place while engineers work around live equipment. For teams standardising high-draw connections across several racks, buying six identical short cords in one kit keeps the rack tidy and the bill of materials simple.<\/p>\n<h2>What the APC AP8712S does in a rack<\/h2>\n<p>The C20 end of each cord plugs into a C19 outlet, the high-current outlet found on many rack PDUs and UPS units, while the C19 end feeds the matching C20 inlet on the equipment. That connector pairing is used on hardware that draws more than an ordinary server cord is meant to carry. Every cord in the kit handles a maximum current draw of 16 A, and that figure is the ceiling for any single device connection. The kit does not change the capacity of the circuit or the PDU behind it, so the load budget is still set upstream, at the breaker and the distribution unit.<\/p>\n<p>The locking mechanism is the reason to choose this kit over plain cords. In a crowded rack, a technician swapping a drive or tracing a network cable can nudge a power cord loose without noticing. On a single-supply device that means an unplanned outage; on a dual-supply device it silently removes redundancy until someone checks the second feed. A locking connector resists that kind of accidental pull, so the cord stays seated until it is released on purpose.<\/p>\n<h3>Why the 0.6 m length matters<\/h3>\n<p>Choosing a short cord is a cable-management decision as much as an electrical one. At 0.6 m, the AP8712S suits devices mounted close to the outlet that feeds them, such as equipment in the section of the rack beside a vertical PDU strip, or a device sitting directly above or below a horizontal unit. Shorter cords mean less excess cable bundled behind the equipment, which keeps the rear of the rack open for airflow and makes it easier to see which cord serves which device during an audit. The trade-off is reach: if the outlet and the inlet sit far apart, a cord this short will be under tension or will not reach at all, and a longer kit is the correct choice.<\/p>\n<h2>Where the AP8712S fits Saudi facilities<\/h2>\n<p>Colocation and enterprise data centres in Riyadh, Jeddah and the Eastern Province run dense racks where every cord left coiled behind equipment adds heat and clutter, so short locking cords suit the tightly planned layouts those halls use. Bank and government server rooms, which tend to run dual-supply equipment under strict change control, benefit from connectors that stop a routine maintenance visit from disconnecting a power feed. Telecom equipment rooms and the network cores of hospitals and universities face the same risk, because technicians work inside the racks more often than they do in a quiet data hall. In each case the kit makes sense where high-draw equipment sits close to its PDU outlet and the operator wants the rear of the cabinet kept clear.<\/p>\n<h2>Choosing between the AP8712S, AP8714S and AP8716R<\/h2>\n<p>Within this cord family, the difference that matters most is length. The AP8712S is the short option at 0.6 m. The AP8714S carries the same C19 to C20 locking pairing at 1.2 m, which suits devices further from the outlet or PDUs mounted on the opposite side of the rack. The AP8716R reaches 1.8 m and ships as a mix of left-angle and right-angle jumper cords, a different answer for connections where a straight connector body would foul a neighbouring cable or panel. Pick the AP8712S when the rack layout puts every device near its outlet and tidy cabling is the priority; step up to the AP8714S when the measured path is longer than a short cord can cover without strain.<\/p>\n<h2>Deployment notes<\/h2>\n<p>Before ordering, measure the actual path from each PDU C19 outlet to the equipment C20 inlet, following the route the cord will take through the cable managers rather than the straight-line distance. Confirm that each device draws no more than the 16 A rating of the cord, and that the circuit and PDU outlet feeding it can carry the load. Seat each connector fully until the lock engages, and route the cord so that it does not cross the hot exhaust of neighbouring hardware. The kit is not rack-mountable: it is a set of loose cords, so no rails or brackets are involved. The cords carry CCC, CSA, PSE and VDE approvals and are UL listed, and the kit comes with a 24-month warranty.<\/p>\n<h2>Package Contents<\/h2>\n<ul>\n<li>Locking C19 to C20 power cord \u00d7 6<\/li>\n<\/ul>\n","protected":false},"excerpt":{"rendered":"<p>Six 0.6 m locking power cords that join C19 outlets to C20 inlets at 16 A, for tidy high-current connections between a PDU and equipment mounted close to it.<\/p>\n","protected":false},"featured_media":20988,"comment_status":"open","ping_status":"closed","template":"","meta":{"_acf_changed":false},"product_brand":[716],"product_cat":[706,849],"product_tag":[],"class_list":["post-18529","product","type-product","status-publish","has-post-thumbnail","product_brand-apc","product_cat-ups-backup-power","product_cat-ups-accessories","first","onbackorder","sale","taxable","shipping-taxable","purchasable","product-type-simple"],"acf":[],"_links":{"self":[{"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/product\/18529","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/comments?post=18529"}],"version-history":[{"count":1,"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/product\/18529\/revisions"}],"predecessor-version":[{"id":18530,"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/product\/18529\/revisions\/18530"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/media\/20988"}],"wp:attachment":[{"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/media?parent=18529"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/product_brand?post=18529"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/product_cat?post=18529"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/product_tag?post=18529"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}