{"id":18554,"date":"2026-11-17T21:32:08","date_gmt":"2026-11-17T18:32:08","guid":{"rendered":"https:\/\/risys.sa\/?post_type=product&#038;p=18554"},"modified":"2026-11-17T21:32:08","modified_gmt":"2026-11-17T18:32:08","slug":"apc-ap8853-metered-rack-pdu","status":"publish","type":"product","link":"https:\/\/risys.sa\/en\/product\/apc-ap8853-metered-rack-pdu\/","title":{"rendered":"APC AP8853 Metered Rack PDU, 0U, 7.4 kW, 36 C13 and 6 C19"},"content":{"rendered":"<p>The APC AP8853 is a metered 0U rack PDU built around one figure: 7.4 kW of single-phase capacity from a 32A, 230V feed. That rating places it in the middle of APC&#8217;s rack distribution range, between the lighter AP8858 and the higher-capacity AP8881, and it is the step a rack takes when its load outgrows a small single-phase circuit but does not yet justify a three-phase supply. The PDU takes its power through an IEC 309 2P+E input connector on a 2.9 m cord and distributes it across 36 C13 and 6 C19 outlets, so one strip can serve a full rack of servers, switches and storage alongside a handful of high-draw devices. Its meter shows the load drawn on the strip, giving the operations team a direct reading of how close the rack is to its 7.4 kW ceiling before a breaker makes the decision for them.<\/p>\n<h2>What metering on the APC AP8853 means day to day<\/h2>\n<p>A metered PDU reports the current the rack is drawing, so capacity planning stops being guesswork. Before a new server goes in, the technician reads the present load and judges whether the 32A circuit has headroom for it. When a rack is commissioned, the reading confirms that the actual load matches the design, and in later audits it shows which racks are close to their limit and which have spare capacity to absorb new equipment. Unlike a basic power strip, the AP8853 makes overload risk visible before it trips the upstream breaker. The serial configuration cable in the box allows the unit to be set up over a serial connection when it is first commissioned.<\/p>\n<h2>Outlet layout and 0U mounting<\/h2>\n<p>The 0U form factor mounts vertically in the side channel of the rack with the supplied rack mounting brackets, leaving every rack unit free for equipment. The C13 outlets suit the power supplies of typical servers, switches, firewalls and network video recorders, while the C19 outlets take higher-draw devices such as blade chassis, storage arrays and chassis switches. Having both connector types on one strip means fewer adaptor cords and a tidier rack. Where a device has a C20 inlet, a locking cord such as the AP8760 links it to one of the C19 outlets and keeps the connection secured.<\/p>\n<h2>Use cases across Saudi sectors<\/h2>\n<p>The 32A single-phase input suits Saudi server rooms and edge sites that are fed from a single-phase supply rather than full three-phase distribution: bank branch hubs, hospital IT rooms, university network rooms and regional telecom nodes. In security operations, one AP8853 can carry a rack of video management servers, recorders, storage and core switching for a city surveillance or campus CCTV project, with the meter giving the facility team a reading they can log on routine inspections. Industrial sites in Jubail, Yanbu and the Eastern Province, where control-room racks are checked on fixed rounds, benefit in the same way: every visit produces a load figure that can be read and recorded.<\/p>\n<h2>Choosing among APC rack PDUs<\/h2>\n<p>The AP8853 is the middle choice in this range. The AP8858 is rated 3.7 kW at 230V on a 16A input and suits lighter racks of network and edge equipment. The AP8881 is rated at 11 kW for racks whose load has grown beyond what the AP8853 carries. Choose the AP8853 when the rack&#8217;s measured or planned load is above what the AP8858 can supply, a single 32A, 230V circuit is available, and an outlet count of 36 C13 and 6 C19 matches the equipment list.<\/p>\n<h2>Deployment notes<\/h2>\n<p>The IEC 309 2P+E input connector needs a matching 32A industrial socket on a dedicated single-phase 230V circuit, which the facility electrician should provide and protect accordingly. The 2.9 m input cord lets the socket sit under a raised floor or above the rack on a cable tray, but its position should be fixed before the rack is populated. Mount the PDU with the supplied brackets, connect the serial configuration cable for setup, and keep the installation guide and safety guide with the rack documentation. Allocate equipment across the outlets so the combined load stays within the 7.4 kW rating. The unit is covered by a 24-month warranty.<\/p>\n<h2>Package Contents<\/h2>\n<ul>\n<li>Installation guide<\/li>\n<li>Rack mounting brackets<\/li>\n<li>Serial configuration cable<\/li>\n<li>Safety guide<\/li>\n<\/ul>\n","protected":false},"excerpt":{"rendered":"<p>Metered 0U rack PDU delivering 7.4 kW single-phase from a 32A, 230V feed, with 36 C13 and 6 C19 outlets and an IEC 309 2P+E input connector.<\/p>\n","protected":false},"featured_media":20983,"comment_status":"open","ping_status":"closed","template":"","meta":{"_acf_changed":false},"product_brand":[716],"product_cat":[851],"product_tag":[],"class_list":["post-18554","product","type-product","status-publish","has-post-thumbnail","product_brand-apc","product_cat-power-distribution-pdu","first","onbackorder","sale","taxable","shipping-taxable","purchasable","product-type-simple"],"acf":[],"_links":{"self":[{"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/product\/18554","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/comments?post=18554"}],"version-history":[{"count":1,"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/product\/18554\/revisions"}],"predecessor-version":[{"id":18555,"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/product\/18554\/revisions\/18555"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/media\/20983"}],"wp:attachment":[{"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/media?parent=18554"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/product_brand?post=18554"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/product_cat?post=18554"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/product_tag?post=18554"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}