{"id":18564,"date":"2026-11-17T21:32:06","date_gmt":"2026-11-17T18:32:06","guid":{"rendered":"https:\/\/risys.sa\/?post_type=product&#038;p=18564"},"modified":"2026-11-17T21:32:06","modified_gmt":"2026-11-17T18:32:06","slug":"apc-ap8858eu3-metered-rack-pdu","status":"publish","type":"product","link":"https:\/\/risys.sa\/en\/product\/apc-ap8858eu3-metered-rack-pdu\/","title":{"rendered":"APC AP8858EU3 Metered Rack PDU, 0U, 3.7 kW, IEC 60309 Plug"},"content":{"rendered":"<p>The APC AP8858EU3 is a metered rack PDU built for cabinets fed from an industrial-style socket. What sets it apart in the APC family is how power reaches it: a locking input power cord, 2.9 m long, ending in an IEC 60309 16 A 2P + E plug, giving the unit a capacity of 3.7 kW on a single-phase 16 A supply. That plug is the round, keyed connector specified in many data centres and plant rooms, and it mates only with a matching socket, which reduces the chance of a cabinet being fed from an outlet rated below its needs. The unit mounts at 0U in the rear channel of the rack and carries 18 C13 outlets and 2 C19 outlets. As a metered model it measures the load passing through it, so the team running the room can compare the cabinet&#8217;s draw against its 16 A limit.<\/p>\n<h2>Why the input cord matters on the APC AP8858EU3<\/h2>\n<p>Most decisions in rack power design are made at the wall, not at the outlets. A PDU that arrives with its own locking cord and an IEC 60309 plug is ready to connect to the socket the electrical contractor has already installed under the raised floor or on the overhead tray. There is no separate cord to source, size or match, and the locking design keeps the cord from working loose during maintenance in a crowded cabinet. The cord length of 2.9 m gives enough reach to run from the rear of the rack to a floor box or a tray above, though the socket position should still be checked against that length before installation. A single input cable feeds the whole unit, which keeps the electrical side of the cabinet simple to trace and to label.<\/p>\n<h2>Measured load and outlet mix<\/h2>\n<p>Being metered, the unit measures the current flowing through it. On a 16 A feed that information has real value: a cabinet that creeps toward its limit as equipment is added will eventually trip the upstream breaker and drop every device on the strip at the same moment. Checking the measured load before each addition lets the team decide whether the next server goes into this cabinet or the next one. The 18 C13 outlets take the standard cords used by servers, access and distribution switches, firewalls, routers and network video recorders. The 2 C19 outlets serve heavier equipment: storage enclosures, chassis-based switches and high-draw servers whose power supplies use the larger connector. Output to the outlets is rated at 230 V, and the unit accepts a nominal input of 200 V, 208 V or 230 V.<\/p>\n<h2>Where the AP8858EU3 fits in Saudi projects<\/h2>\n<p>Many data halls run by telecom carriers and colocation providers in Riyadh, Jeddah and Dammam deliver power to each cabinet through industrial sockets, and this unit plugs straight into that infrastructure. The same applies to equipment rooms in hospitals, banks and ministries where the electrical contractor has standardised on IEC 60309 outlets for IT loads. In petrochemical and utility control buildings, where a cabinet may hold SCADA servers, historians and network gear, the locking cord adds a practical safeguard against accidental disconnection. Security integrators building central monitoring rooms can place recorders, video management servers and core switches on the C13 outlets and keep the C19 outlets for the storage arrays that hold weeks of footage.<\/p>\n<h2>AP8858EU3 or AP8858: picking the right variant<\/h2>\n<p>The two models share the metered design, the same mix of C13 and C19 outlets and the same 0U form. What separates them is the connection to the building. The AP8858 uses an inlet that takes a separately chosen cord and is rated 3.3kW at 208V 16A or 3.7kW at 230V 16A. Choose the AP8858EU3 when the room is already fitted with IEC 60309 16 A sockets and you want the cord delivered with the unit; choose the AP8858 when the cord has to suit a different socket type or a UPS output. For larger loads, the AP8881 moves to three-phase power at 11 kW. The AP8886 is rated at 32 A.<\/p>\n<h2>Installation checklist<\/h2>\n<h3>Rack and mounting<\/h3>\n<p>Confirm that the cabinet has 0U mounting points in its rear channel and enough depth behind the equipment for a vertical strip. The rack mounting brackets in the box fix the unit in place, and the installation guide shows the positions.<\/p>\n<h3>Electrical supply<\/h3>\n<p>Provide a single-phase 16 A circuit terminated in an IEC 60309 16 A 2P + E socket within reach of the 2.9 m cord. Keep the total connected load within the 3.7 kW rating, and spread high-draw equipment so the measured figure leaves headroom.<\/p>\n<h3>Setup and warranty<\/h3>\n<p>The serial configuration cable in the box is used for initial setup, and the safety guide should be read before the unit is energised. The AP8858EU3 carries a 24-month warranty.<\/p>\n<h2>Package Contents<\/h2>\n<ul>\n<li>Installation guide<\/li>\n<li>Locking input power cord<\/li>\n<li>Rack mounting brackets<\/li>\n<li>Serial configuration cable<\/li>\n<li>Safety guide<\/li>\n<\/ul>\n","protected":false},"excerpt":{"rendered":"<p>A 0U APC metered rack PDU rated 3.7 kW at 16 A, with 18 C13 and 2 C19 outlets and a 2.9 m locking input cord ending in an IEC 60309 16 A 2P + E plug.<\/p>\n","protected":false},"featured_media":20981,"comment_status":"open","ping_status":"closed","template":"","meta":{"_acf_changed":false},"product_brand":[716],"product_cat":[851],"product_tag":[],"class_list":["post-18564","product","type-product","status-publish","has-post-thumbnail","product_brand-apc","product_cat-power-distribution-pdu","first","onbackorder","sale","taxable","shipping-taxable","purchasable","product-type-simple"],"acf":[],"_links":{"self":[{"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/product\/18564","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/comments?post=18564"}],"version-history":[{"count":1,"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/product\/18564\/revisions"}],"predecessor-version":[{"id":18565,"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/product\/18564\/revisions\/18565"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/media\/20981"}],"wp:attachment":[{"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/media?parent=18564"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/product_brand?post=18564"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/product_cat?post=18564"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/product_tag?post=18564"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}