{"id":18754,"date":"2026-11-17T21:31:59","date_gmt":"2026-11-17T18:31:59","guid":{"rendered":"https:\/\/risys.sa\/?post_type=product&#038;p=18754"},"modified":"2026-11-17T21:31:59","modified_gmt":"2026-11-17T18:31:59","slug":"apc-epdu1116m-metered-rack-pdu","status":"publish","type":"product","link":"https:\/\/risys.sa\/en\/product\/apc-epdu1116m-metered-rack-pdu\/","title":{"rendered":"APC EPDU1116M Metered Rack PDU, 0U Vertical, 18 C13 and 3 C19"},"content":{"rendered":"<p>The APC EPDU1116M is a vertical metered rack PDU for full-height server racks, combining outlet density with load visibility in one strip. It mounts at the side of the rack in 0U, distributes a 16 A supply to 18 IEC 60320 C13 and 3 IEC 60320 C19 outlets, and is rated for a load capacity of 3680 VA. Within the APC family it is the balanced choice for a rack that is still growing: enough outlets for a busy rack, and metering that shows when it is nearing its limit, without stepping up to higher-capacity units the load does not yet need. Power arrives on a single 2.99 m cord with an IEC 60309 16 A 2P + E plug, the unit accepts 200 V, 208 V or 230 V at 50\/60 Hz, and the outlets deliver 230 V.<\/p>\n<h2>Why metering matters on the APC EPDU1116M<\/h2>\n<p>A rack rarely stays the way it was handed over. A server is added next quarter, then a switch, then a storage shelf, and each addition moves the total closer to the 16 A limit without anyone noticing. The EPDU1116M shows the load the strip is carrying, so the team knows how much headroom remains before each addition instead of finding out when a breaker trips and everything in the rack goes down.<\/p>\n<p>For whoever runs the server room, that reading makes it practical to balance equipment across the strips on either side of the rack, and to move a device from a heavily loaded strip to a lighter one before it becomes an outage. It also helps when reviewing the room&#8217;s power consumption or judging whether a rack can take one more server.<\/p>\n<h2>Outlets and vertical mounting in real use<\/h2>\n<p>Because the unit is a vertical strip, an outlet sits close to every device along the height of the rack, cords stay short and tidy, and no rack units are given up to power distribution. The 18 IEC 60320 C13 outlets cover switches, routers, standard servers and recorders, while the 3 IEC 60320 C19 outlets accept the higher-current cords of larger servers and storage arrays.<\/p>\n<h2>Applications across Saudi sectors<\/h2>\n<p>Server rooms at banks, insurers and private hospitals in Riyadh, Jeddah and Al Khobar tend to grow step by step as new systems go live, and that is exactly the pattern a metered strip is built for: the rack is fitted out with part of its capacity today and its load is checked every time something is added.<\/p>\n<p>In digital transformation projects at government entities and universities, racks are often handed from installation teams to separate operations teams. Metering gives the operations side a way to verify load without going back to the original design calculations. Control rooms for large surveillance systems, which expand in phases with more recorders and storage servers, benefit from the same mix: C13 outlets for recorders and switches, C19 outlets for storage servers, and a load reading that shows when a new rack is due.<\/p>\n<p>The rated relative humidity range of 5 to 95 % suits server rooms in coastal cities such as Jeddah, Dammam and Jubail, where humidity can be high in some facilities.<\/p>\n<h2>Weighing the EPDU1116M against the EPDU1116B and EPDU1016M<\/h2>\n<p>The EPDU1116B is the closest sibling: the same vertical format and plug type, slightly more outlets, but no metering. Pick it when the rack load is calculated, fixed and not expected to change; pick the EPDU1116M when the rack will grow and you want to see the effect of every addition.<\/p>\n<p>The EPDU1016M shares the metering, but it is a compact horizontal strip with far fewer outlets and no higher-current outlets, intended for small cabinets at branches and surveillance sites. For a full-height rack holding servers, the EPDU1116M is the better match of the two.<\/p>\n<h2>Installation notes<\/h2>\n<p>Provide an IEC 60309 16 A 2P + E socket near the rack at 200 V, 208 V or 230 V and 50\/60 Hz, positioned so the 2.99 m cord reaches it without strain. Mount the strip vertically at the side of the rack with the supplied vertical mounting brackets, and check beforehand that the rack has side space for a strip of this length.<\/p>\n<p>After connecting and powering up, note the first load reading as a baseline and keep the connected equipment under the 3680 VA capacity with room to expand. If you fit a strip on each side of the rack, spread the equipment so the two readings stay close. The installation guide and user manual in the box cover the mounting and start-up steps in detail.<\/p>\n<h2>Package Contents<\/h2>\n<ul>\n<li>Installation guide<\/li>\n<li>User manual<\/li>\n<li>Vertical mounting brackets<\/li>\n<\/ul>\n","protected":false},"excerpt":{"rendered":"<p>A 0U vertical metered rack PDU with 18 IEC 60320 C13 and 3 IEC 60320 C19 outlets and 3680 VA capacity, for full-height server racks whose load grows and needs watching.<\/p>\n","protected":false},"featured_media":20975,"comment_status":"open","ping_status":"closed","template":"","meta":{"_acf_changed":false},"product_brand":[716],"product_cat":[851],"product_tag":[],"class_list":["post-18754","product","type-product","status-publish","has-post-thumbnail","product_brand-apc","product_cat-power-distribution-pdu","first","onbackorder","sale","taxable","shipping-taxable","purchasable","product-type-simple"],"acf":[],"_links":{"self":[{"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/product\/18754","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/comments?post=18754"}],"version-history":[{"count":1,"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/product\/18754\/revisions"}],"predecessor-version":[{"id":18755,"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/product\/18754\/revisions\/18755"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/media\/20975"}],"wp:attachment":[{"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/media?parent=18754"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/product_brand?post=18754"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/product_cat?post=18754"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/product_tag?post=18754"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}