{"id":8311,"date":"2026-11-14T01:24:35","date_gmt":"2026-11-13T22:24:35","guid":{"rendered":"https:\/\/risys.sa\/?post_type=product&#038;p=8311"},"modified":"2026-11-14T01:24:35","modified_gmt":"2026-11-13T22:24:35","slug":"zkteco-zk-sc103-rfid-access-control-terminal","status":"publish","type":"product","link":"https:\/\/risys.sa\/en\/product\/zkteco-zk-sc103-rfid-access-control-terminal\/","title":{"rendered":"ZKTeco ZK-SC103 RFID Standalone Access Control Terminal"},"content":{"rendered":"<p>ZKTeco SC103 is a standalone RFID access controller for a card-led entrance design, with DC 12V power and an LCD. Its selection starts with a practical question: does the site want staff to use ID cards at the door, with connections for the surrounding entrance hardware? For a Saudi office, service facility or administrative entrance, this gives the security team a focused basis for planning credentials, wiring and daily operation. The controller combines card storage, transaction storage and several communication interfaces. Assess the electrical supply and card technology together with the door connections, so procurement reflects the entrance being built and the way the facilities team intends to run it.<\/p>\n<h2>ZKTeco SC103: build around ID cards<\/h2>\n<p>The controller supports ID card authentication, with Mifare and HID Prox offered as optional card technologies. An organisation with existing staff cards should establish which technology it uses before selecting the configuration. That decision belongs early in procurement because a card-based workflow depends on matching the credentials to the chosen reader configuration. For a new installation, agree the card policy with the team issuing credentials, then use that policy consistently when specifying the controller and organising staff enrolment.<\/p>\n<p>SC103 accommodates 30,000 ID cards and 50,000 transactions. The card database relates to the credentials enrolled for access, while transaction capacity relates to stored activity. Evaluate each against the planned user population and entrance use. A large card population does not itself describe how often the entrance will be used, so operations should also consider record-handling routines. Assign responsibility for keeping the card population current as staff join, leave or change roles, and include that responsibility in the handover.<\/p>\n<h2>Connections at the door<\/h2>\n<p>Lock, alarm, exit and door sensor connections let the installer plan the controller alongside the hardware involved in the entrance. Review the lock connection with the door contractor, the exit connection with the intended departure procedure and the door sensor connection with the opening being monitored. Include the alarm connection in the security wiring review. Mapping these connections before installation helps different contractors work to an agreed door design rather than making independent assumptions about the same entrance.<\/p>\n<p>The LCD provides a local display at the controller. Consider the position of the unit in relation to the people presenting cards and the staff responsible for local operation. At an employee entrance serving a Saudi commercial building, the practical requirement is a clear card-use routine that reception, security and facilities can explain consistently. In an industrial administration area, the same planning should account for the teams who manage credentials and the contractors who maintain door hardware.<\/p>\n<h2>Network and serial integration planning<\/h2>\n<p>Communication options include TCP\/IP, RS485 and USB host, with Wiegand input\/output. The serial interface is specified as RS232\/485. Have the installer identify the interface required by the intended system and map the corresponding cable route. Wiegand direction also deserves explicit review when connecting other access equipment. Treat the network and serial choices as parts of the site design, with the security and network teams agreeing where the controller connects and who owns each installation task.<\/p>\n<h2>Choosing SC103 within the family<\/h2>\n<p>SC103 suits a selection centred on card credentials and a DC 12V installation. ProFAC brings face and RFID authentication into the comparison when facial matching is part of the entrance brief. SC503 offers a card-based alternative with a doorbell interface among its door connections. These distinctions help procurement focus on the required entry process and peripheral wiring. Compare the functions needed at the particular opening, including whether a doorbell connection matters, before settling on a model.<\/p>\n<p>For SC103 deployment, coordinate the DC 12V supply with the lock, alarm, exit and sensor wiring plan. Confirm the selected card technology, identify the communication interface and arrange a handover covering credential administration and transaction handling. This puts the power requirement, card workflow and connected entrance hardware into the same installation plan.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Standalone RFID access control powered by DC 12V, with an LCD and connections for the lock, alarm, exit and door sensor. Supports 30,000 ID cards and 50,000 transactions; Mifare and HID Prox are optional.<\/p>\n","protected":false},"featured_media":20534,"comment_status":"open","ping_status":"closed","template":"","meta":{"_acf_changed":false},"product_brand":[678],"product_cat":[680],"product_tag":[],"class_list":["post-8311","product","type-product","status-publish","has-post-thumbnail","product_brand-zkteco","product_cat-access-control","first","onbackorder","taxable","shipping-taxable","purchasable","product-type-simple"],"acf":[],"_links":{"self":[{"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/product\/8311","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/comments?post=8311"}],"version-history":[{"count":1,"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/product\/8311\/revisions"}],"predecessor-version":[{"id":8312,"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/product\/8311\/revisions\/8312"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/media\/20534"}],"wp:attachment":[{"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/media?parent=8311"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/product_brand?post=8311"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/product_cat?post=8311"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/product_tag?post=8311"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}