{"id":9328,"date":"2026-11-17T22:16:17","date_gmt":"2026-11-17T19:16:17","guid":{"rendered":"https:\/\/risys.sa\/?post_type=product&#038;p=9328"},"modified":"2026-11-18T20:57:46","modified_gmt":"2026-11-18T17:57:46","slug":"apc-srtg8kxli-online-ups","status":"publish","type":"product","link":"https:\/\/risys.sa\/en\/product\/apc-srtg8kxli-online-ups\/","title":{"rendered":"APC SRTG8KXLI 8kVA\/8kW Online Smart-UPS, Rack\/Tower"},"content":{"rendered":"<p>APC SRTG8KXLI is an online UPS from the Smart-UPS family rated at 8kVA and 8kW, and the fact that its watt rating matches its VA rating is the detail that matters most when you size it. Every kilowatt on the label is available to real equipment, so a load list measured in watts can be checked against the unit directly, without first derating an apparent-power figure. Within the family it holds the balanced middle of the SRTG line: enough capacity for a full equipment room or several mixed racks, without paying for the largest frames in the series. It runs at 230V, converts between rack and tower installation, comes with a network card, and ships with an external battery pack and its battery cable, so the external battery is part of the same delivery rather than a separate order.<\/p>\n<h2>Sizing a load on the APC SRTG8KXLI<\/h2>\n<p>Start from the measured or nameplate wattage of everything you intend to protect: switches, servers, recorders, storage and any control equipment in the same room. Add it up and compare the total with the 8kW rating, leaving headroom for growth and for the inrush when equipment starts. Because this is an online design, the connected load is fed continuously by the UPS instead of being switched over to it when the mains fails, which suits equipment that reacts badly to even a momentary break, such as storage arrays and continuous CCTV recording.<\/p>\n<p>The network card lets the operations centre follow the unit&#8217;s status without a visit to the equipment room, while the USB and network cables in the box cover first-time setup from a nearby computer.<\/p>\n<h2>Where it is deployed in the Kingdom<\/h2>\n<p>Ministry and government server rooms often need one unit that protects several cabinets together, and this rating covers that without splitting the load across multiple smaller UPSs. Universities use this class for the small data centres behind academic and administrative systems, while malls and airports put it in the central CCTV recording rooms where losing minutes of footage is not acceptable. Telecom operators install it at aggregation sites, and hospitals rely on it for the health-information and archiving servers that have to stay available around the clock.<\/p>\n<h2>SRTG8KXLI or a neighbouring model?<\/h2>\n<p>The SRTG6KXLI is the step down and suits sites whose load stays clearly below this unit&#8217;s capacity, so there is no reason to pay for headroom that will never be used. The next step up is the SRTG10KXLI at 10kW, followed by the SRTG15KXLI and the SRTG20KXLI for data centres and large equipment rooms. The SRTG8KXLI is the balanced pick when the load outgrows the smaller models by a clear margin without reaching the level of the largest frames; if everything you protect fits in a single cabinet, the rack-focused SRTL models are the more economical route.<\/p>\n<h2>Before installation day<\/h2>\n<p>The box includes rack mounting brackets but not a rail kit, so if the unit is going into a cabinet, order rails that match the cabinet depth in advance to avoid delaying commissioning. Plan a position for the external battery pack next to the UPS so the supplied battery cable reaches it without strain. A load of this size calls for a dedicated electrical circuit prepared by a qualified electrician, so confirm that with the facilities team before delivery. For floor installation use the stabilization feet, register the network card&#8217;s address with the IT team, and keep the installation manuals in the site file.<\/p>\n<h2>Package Contents<\/h2>\n<ul>\n<li>USB cable<\/li>\n<li>RJ45 cable<\/li>\n<li>Rack mounting brackets \u00d7 2<\/li>\n<li>Stabilization\/wall-mount feet \u00d7 2<\/li>\n<li>Installation manual \u00d7 2<\/li>\n<li>C13-C14 power cable<\/li>\n<li>External battery pack<\/li>\n<li>Battery cable<\/li>\n<\/ul>\n","protected":false},"excerpt":{"rendered":"<p>Online Smart-UPS rated 8kVA and 8kW at 230V, with a network card and an external battery pack in the box. Converts between rack and tower installation.<\/p>\n","protected":false},"featured_media":21392,"comment_status":"open","ping_status":"closed","template":"","meta":{"_acf_changed":false},"product_brand":[716],"product_cat":[843,706],"product_tag":[],"class_list":["post-9328","product","type-product","status-publish","has-post-thumbnail","product_brand-apc","product_cat-online-ups","product_cat-ups-backup-power","first","onbackorder","sale","taxable","shipping-taxable","purchasable","product-type-simple"],"acf":[],"_links":{"self":[{"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/product\/9328","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/comments?post=9328"}],"version-history":[{"count":1,"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/product\/9328\/revisions"}],"predecessor-version":[{"id":9329,"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/product\/9328\/revisions\/9329"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/media\/21392"}],"wp:attachment":[{"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/media?parent=9328"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/product_brand?post=9328"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/product_cat?post=9328"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/risys.sa\/en\/wp-json\/wp\/v2\/product_tag?post=9328"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}