APC PDM3516IEC-680 Power Distribution Module, 680 cm Lead
The middle length of three electrically identical APC power distribution modules: a 400 V three-phase feed at 16 A per line, carried over a 680 cm grey cable to one IEC 309 16 A outlet.
Original price was: 2,910.47 SAR.2,735.84 SARCurrent price is: 2,735.84 SAR. excl. VAT
Available on backorder
RISYS can programme and prepare devices before delivery. Contact us for quantity and project details.
Wholesale and project supply — up to 45% off











Up to 45% off wholesale supply.
Overview
The APC PDM3516IEC-680 is the middle length of three power distribution modules that differ only in their cable: it carries a 400 V three-phase feed, rated at 16 A on each line, across a 680 cm grey cable to one IEC 309 16 A outlet at the rack. It reaches further than the PDM3516IEC-620 without going to the full length of the PDM3516IEC-740, which makes it the balanced pick when a rack stands a few positions along the row from its source, or when the route has to climb into overhead trays before dropping into the cabinet. Its electrical figures do not change with the extra reach: 16 A maximum line current and maximum current draw, a 16 A breaker rating, 50 Hz operation, and an output listed at 230 V and at 400 V three-phase. CE and VDE marks and a 12-month warranty apply.
How the APC PDM3516IEC-680 fits into a rack power chain
Think of a rack’s power path as three links: the distribution source, the feed to the cabinet, and the rack PDU that serves individual devices. The PDM3516IEC-680 is the middle link. Because it is assembled and terminated at the factory, the feed becomes a part you order by model number rather than a piece of site work, and replacing it later means unplugging one module and fitting another of the same length.
Planning a rack around this module starts with its 16 A per line limit. Each of the three phases can carry up to that figure, so the practical approach is to list the equipment going into the cabinet, assign it across the three phases, and keep each phase comfortably below the rating to allow for start-up current and future additions. A cabinet that would push any single phase beyond 16 A needs a second feed or a module with a higher current rating.
The single IEC 309 16 A outlet takes the matching industrial plug, normally the input lead of a single-phase or three-phase rack PDU. With the output listed at both 230 V and 400 V three-phase, confirm which of those the chosen rack PDU expects before the two are paired.
Saudi deployments suited to the 680 cm reach
Mid-sized server rooms are where the extra length earns its place. In the regional data rooms of banks, the operations buildings of airports and seaports, and the network cores of hotel and hospitality groups in Makkah and Madinah, racks are often lined up in a single row with the distribution source at one end, so the cabinets in the middle need more reach than the nearest one.
Security and surveillance projects are another fit. Command-and-control rooms for municipalities, stadium operations centres and large retail malls house rows of recording servers, video management workstations and network switches whose combined load per cabinet stays within a 16 A per line budget. Using one module length for every cabinet in the middle of such a row simplifies ordering and keeps the spares shelf short.
Telecom and fibre operators expanding aggregation sites across the Kingdom face the same pattern: new cabinets added further along an existing row, fed from a source that cannot move. A factory-built feed of fixed length turns each addition into a repeatable job.
Positioning the PDM3516IEC-680 against the 620 and 740 models
Electrically, the PDM3516IEC-620, PDM3516IEC-680 and PDM3516IEC-740 are the same module: 400 V three-phase in, 16 A per line, one IEC 309 16 A outlet. Only the cable length separates them, so the choice is made with a tape measure rather than a load calculation.
The PDM3516IEC-680 is the safe middle option when a route comes close to the limit of the PDM3516IEC-620, or when the exact rack position is not yet fixed during design and some allowance is prudent. If the measured route still runs longer, the PDM3516IEC-740 is the next step. Going straight to the longest model for every rack is not a shortcut: surplus cable has to be coiled somewhere, and coils on top of cabinets or under floor tiles block airflow and make circuits harder to trace.
Commissioning notes
Before ordering, walk the route from the source to the cabinet and add the vertical rises at both ends; the total must fit within 680 cm without tension on the connector. Confirm a 400 V three-phase supply at 50 Hz, upstream protection specified by the site electrical engineer for a 16 A circuit, and an IEC 309 16 A plug of matching configuration on the equipment being fed.
During commissioning, measure the load on each phase once the rack is populated and record it against the module’s 16 A rating, so the next team knows how much headroom remains. The grey finish separates the feed visually from other services in shared trays. The module is covered by a 12-month warranty, and its CE and VDE marks belong in the submittal package for consultant approval.
Package Contents
- Power distribution module
- Installation guide
Technical Specifications
- Brand
- APC
- Warranty
- 1 Year
- Model
- PDM3516IEC-680
Frequently Asked Questions
How does the PDM3516IEC-680 differ from the PDM3516IEC-620?
The electrical design is the same; the difference is the cable. The PDM3516IEC-680 has a 680 cm lead, giving it more reach toward racks further along the row.
How much load can a rack draw through the APC PDM3516IEC-680?
Its input is 400 V three-phase, with a maximum line current of 16 A, a maximum current draw of 16 A and a 16 A breaker rating.
What output voltage does it provide?
The output is listed at 230 V and at 400 V three-phase, delivered through one IEC 309 16 A outlet.
What is in the box?
The power distribution module and an installation guide.

APC UPS systems keep servers and network cabinets running through outages and unstable mains, and the wider APC range extends into the racks, power distribution and sensors around them. APC began in the United States as American Power Conversion and
Browse brand productsDelivery across Saudi Arabia
Clear warranty
Some devices or frequencies may require a permit or approval depending on the intended use and the regulations in force in the Kingdom. Requirements are clarified before project orders are fulfilled.
Customer Reviews
No ratings yet for this product
Only logged in customers who have purchased this product may leave a review.
Related Products
APC AP6120A Rack PDU, 7 C13 + 2 C19 Outlets, 20A Input
On backorder
APC AP7820B Metered Rack PDU, 1U, 8 x C13 Outlets
On backorder
APC AP7155B In-Line Current Meter, 32A 230V, IEC309 Plug
On backorder
APC ER7PDUBRKTS Single-Width PDU Mounting Bracket Kit
On backorder