APC PDM3532IEC-200 Power Distribution Module

A power distribution module with a 200 cm output cable for nearby connections. Features a 400 V three-phase input, a 32 A maximum line current and circuit monitoring.

ModelPDM3532IEC-200

Original price was: 2,645.42 SAR.Current price is: 2,486.69 SAR. excl. VAT

Available on backorder

WhatsApp Inquiry

RISYS can programme and prepare devices before delivery. Contact us for quantity and project details.

Wholesale and project supply — up to 45% off

Minimum order5 units

Shipping and delivery icon
Fast shipping
SMSA Express logoFedEx logoNAQEL Express logoDHL logo
Product warranty icon
Genuine warranty
All products carry a one-year authorised-agent warranty.
Secure payment icon
Secure payment
madaVisaMastercardApple Pay
B2B sales icon
B2B/B2C supply

Up to 45% off wholesale supply.

Overview

APC PDM3532IEC-200 puts a shorter output cable at the centre of the selection decision. This power distribution module has a 200 cm output cable, making it the compact-route option alongside PDM3532IEC-620 and PDM3532IEC-1040. It is intended for an electrical arrangement matched to its 400 V three-phase input, 32 A maximum line current and IEC 309 outlet. A three-pole breaker and circuit monitoring are part of the module. For a buyer equipping a site, the value of this configuration is in matching the cable to a nearby connection point. Survey the route first, then check the supply characteristics and receiving connector before committing it to the installation schedule.

APC PDM3532IEC-200 for nearby connections

The shorter cable is relevant where the distribution arrangement places the destination close to the module. A nearby endpoint can still require a longer path than the straight-line distance suggests, so include the approach to the connector and the planned cable routing in the measurement. This version is worth considering when the complete path fits its output cable. Give the installer the intended route as well as the model number so that the physical layout and the purchasing decision remain aligned through delivery and installation.

Planning around the actual cable length also helps keep the surrounding equipment area organised. Identify the route through the installation, the points where the cable needs support and the position of the final connection. Leave the connection accessible for the site’s inspection procedures. Where the destination is close, choosing the appropriate cable version avoids specifying an unnecessarily long route arrangement. The decision remains a practical layout choice: the output cable needs to reach the correct endpoint using the approved path, with its routing agreed by the responsible electrical team.

Check voltage, frequency and circuit load

Input voltage is 400 V three-phase, and the stated operating frequency is 50 Hz. A Saudi facilities project should check those requirements against the particular supply being used. Verify the connection point during design review rather than assuming that the building’s general power description establishes suitability. This is a useful distinction for contractors purchasing equipment across different premises or electrical systems. Both voltage and frequency need to match the intended arrangement before the module can be selected for that part of the project.

The maximum line current is 32 A, as is the maximum current draw. Use these ratings when the electrical designer reviews the proposed load. The module’s shorter output cable does not replace that load assessment, and cable length should not be used as a proxy for capacity. Keep the current requirements in the purchase specification alongside the model reference. Doing so gives the procurement and installation teams a shared description of the electrical configuration, particularly when several distribution modules are being considered for different connection points.

Outlet, breaker and monitoring

A single IEC 309 32 A outlet defines the outgoing connection. Check the receiving connector against that interface before placing the order, and include the connection requirement in the handover documentation. The built-in breaker is three-pole, and circuit monitoring is supported. These are relevant to how the module is incorporated into the site’s protection and operational arrangements. Assign the circuit a clear identity on the installation records so that the facilities team can relate the physical module to the electrical drawings during routine review and maintenance planning.

Where the short-route version fits

In a Saudi commercial equipment room, a facilities upgrade or a contractor-led distribution project, this version can be considered where the planned endpoint is nearby and the electrical requirements match. PDM3532IEC-620 offers a longer cable route, and PDM3532IEC-1040 is the extended-reach alternative. Select between them by measuring the installation path rather than ordering extra length automatically. This module is grey and has a 1 Year warranty. At handover, retain the full model identification, the approved connection path and the circuit reference together. That record helps the operating team order the same configuration later and gives future layout changes a clear starting point for another electrical review.

Package Contents

  • Power distribution module
  • Installation guide

Technical Specifications

Brand
APC
Warranty
1 Year
Model
PDM3532IEC-200

Frequently Asked Questions

How long is the output cable?

The output cable is 200 cm long.

What is the maximum line current?

Maximum line current and maximum current draw are 32 A.

Which supply frequency is specified?

The module specifies 50 Hz with a 400 V three-phase input.

What protection and monitoring are included?

The module includes a three-pole breaker and circuit monitoring.

Brand
APC

APC UPS systems keep servers and network cabinets running through outages and unstable mains, and the wider APC range extends into the racks, power distribution and sensors around them. APC began in the United States as American Power Conversion and

Browse brand products
Shipping, Warranty and Regulatory

Delivery across Saudi Arabia

Clear warranty

Some devices or frequencies may require a permit or approval depending on the intended use and the regulations in force in the Kingdom. Requirements are clarified before project orders are fulfilled.

Customer Reviews

No ratings yet for this product

Reviews

There are no reviews yet.

Only logged in customers who have purchased this product may leave a review.

Related Products

APC

APC APDU9941 Switched Rack PDU 30A, 200V/208V

Model APDU9941
0U21 C13200V
Original price was: 6,351.02 SAR.Current price is: 5,969.96 SAR. excl. VAT Save 381.06 SAR

On backorder

Request a Quote
APC

APC AP8653 Metered-by-Outlet Switched Rack PDU 32A

Model AP8653
ZeroUNetwork
Original price was: 8,476.36 SAR.Current price is: 7,967.78 SAR. excl. VAT Save 508.58 SAR

On backorder

Request a Quote
APC

APC APDU9953 Switched Rack PDU, 32A 230V, 21 C13 + 3 C19

Model APDU9953
ZeroU24
Original price was: 6,100.98 SAR.Current price is: 5,734.92 SAR. excl. VAT Save 366.06 SAR

On backorder

Request a Quote
APC

APC ER7PDUBRKT Double-Width PDU Mounting Brackets, Black

Model ER7PDUBRKT
Easy Rack PDU mountin...
Original price was: 200.03 SAR.Current price is: 188.03 SAR. excl. VAT Save 12.00 SAR

On backorder

Request a Quote

Original price was: 2,645.42 SAR.Current price is: 2,486.69 SAR. excl. VAT