Wholesale & retail - B2B/B2C
Free site survey in Riyadh
Shipping across the Kingdom
Warranty on all products
BrandAPC

APC PDM3532IEC-740 Power Distribution Module

Power distribution module with a 740 cm output cable and 400 V three-phase input. Features a single IEC 309 32 A outlet and a 32 A three-pole breaker.

ModelPDM3532IEC-740

Original price was: 2,995.48 SAR.Current price is: 2,815.75 SAR. excl. VAT

Available on backorder

WhatsApp Inquiry

RISYS can programme and prepare devices before delivery. Contact us for quantity and project details.

Wholesale and project supply — up to 45% off

Minimum order5 units

Shipping and delivery icon
Fast shipping
SMSA Express logoFedEx logoNAQEL Express logoDHL logo
Product warranty icon
Genuine warranty
All products carry a one-year authorised-agent warranty.
Secure payment icon
Secure payment
madaVisaMastercardApple Pay
B2B sales icon
B2B/B2C supply

Up to 45% off wholesale supply.

Overview

APC PDM3532IEC-740 is a power distribution module with a 740 cm output cable for projects where the connection route extends away from the distribution position. Its value in a purchasing schedule comes from matching that reach to the actual site layout while retaining a clearly defined electrical configuration. The module accepts a 400 V three-phase input at 50 Hz and has a maximum line current of 32 A. For facilities managers coordinating technical rooms across a Saudi campus or commercial development, this makes route measurement a practical part of model selection. Assess the path first, then confirm that the receiving connection and the planned load suit the module before placing the order.

Planning around APC PDM3532IEC-740

The output cable gives the installer a fixed length to work into the distribution layout. Follow the intended route through the room rather than estimating from the distance between equipment fronts. Changes in direction and the final approach to the receiving connection all affect the usable path. A well-defined routing drawing lets procurement choose this particular version for a known location. It also gives the contractor a clear installation target when several similar distribution modules appear in the same project schedule.

Connection and load requirements

A single IEC 309 32 A outlet provides the output connection. Confirm that the intended receiving equipment uses the corresponding interface, and include the outlet designation in the electrical submittal. The maximum current draw is 32 A, so the connected load must be reviewed as part of the distribution design. Treat the outlet type, current limit and supply arrangement as a linked decision. A suitable cable route is useful only when the electrical connection at the end of that route is also appropriate.

Three-phase supply and breaker arrangement

This model uses a 400 V three-phase input with a 50 Hz supply frequency. It incorporates a three-pole breaker rated at 32 A. Those characteristics help the electrical engineer identify the module’s place in the protection arrangement and check coordination with the upstream circuit. During design review, connect the model reference to the intended circuit so installers do not have to infer its role from its appearance. The grey finish can be included in the physical equipment description used for inspection and handover.

Applications across technical spaces

In a Saudi office development, the module can be considered for a technical area where the planned cable path requires its reach and connection. In a logistics facility, the same assessment can be made for a communications or operations room. A hospital facilities department can evaluate it within the electrical design for its technical infrastructure. In each setting, selection depends on the circuit and receiving equipment. Establishing those conditions before ordering helps the project team avoid selecting distribution hardware solely because it belongs to a familiar product family.

Comparing the available cable choices

Place PDM3532IEC-680 and PDM3532IEC-80 alongside this model when reviewing alternative layouts, and use the intended routing plan to resolve the choice. For this unit, the 740 cm output cable is the physical requirement to check against the site. Where different rooms have different connection positions, assign a specific model to each location rather than leaving the choice to installation day. That approach keeps the order aligned with the drawings and lets the facilities team understand why this version was selected for a particular circuit.

Installation planning that remains useful later

Keep the cable route accessible for inspection and take the connection approach into account when deciding where the module will serve the installation. The installation guide should accompany the contractor’s preparation and remain available to the maintenance team. Record the final route in the handover documents, particularly when cabinets or service routes may change later. When equipment is relocated, the recorded cable path gives the responsible engineer a starting point for reviewing the effect on the existing distribution arrangement.

What to include in the purchase review

Use the full model name, required input supply, outlet interface and output cable length in the procurement schedule. The module carries a 1 Year warranty, and its certifications include CE and VDE. These details can be carried into the relevant project documentation alongside the electrical review. Before accepting a proposed substitution, return to the original routing and circuit requirements. A purchasing decision based on the intended connection, protection arrangement and installed path gives the operations team a configuration they can identify and maintain.

Package Contents

  • Installation guide

Technical Specifications

Brand
APC
Warranty
1 Year
Model
PDM3532IEC-740

Frequently Asked Questions

What cable length does this version provide?

This version has a 740 cm output cable.

What breaker is incorporated?

It has a three-pole circuit breaker rated at 32 A.

Which outlet type does it use?

It provides one IEC 309 32 A outlet.

What are its input requirements?

The input is 400 V three-phase at 50 Hz; maximum current draw is 32 A.

Brand
APC

APC UPS systems keep servers and network cabinets running through outages and unstable mains, and the wider APC range extends into the racks, power distribution and sensors around them. APC began in the United States as American Power Conversion and

Browse brand products
Shipping, Warranty and Regulatory

Delivery across Saudi Arabia

Clear warranty

Some devices or frequencies may require a permit or approval depending on the intended use and the regulations in force in the Kingdom. Requirements are clarified before project orders are fulfilled.

Customer Reviews

No ratings yet for this product

Reviews

There are no reviews yet.

Only logged in customers who have purchased this product may leave a review.

Related Products

APC

APC AP6120A Rack PDU, 7 C13 + 2 C19 Outlets, 20A Input

Model AP6120A
240V
Original price was: 450.07 SAR.Current price is: 423.07 SAR. excl. VAT Save 27.00 SAR

On backorder

Request a Quote
APC

APC AP8958EU3 0U Rack PDU 16A 230V with IEC309 Cord

Model AP8958EU3
0U7 IEC-320-C13 and 1 I...230V
Original price was: 5,350.86 SAR.Current price is: 5,029.81 SAR. excl. VAT Save 321.05 SAR

On backorder

Request a Quote
APC

APC AP7822B Metered Rack PDU, 32A, 2U, C13 and C19

Model AP7822B
2 YearsRack-mounted200 V
Original price was: 3,725.60 SAR.Current price is: 3,502.06 SAR. excl. VAT Save 223.54 SAR

On backorder

Request a Quote
APC

APC AP4421A Rack Automatic Transfer Switch 1U 10A

Model AP4421A
1Uinput: 1 IEC 60320 C1...
Original price was: 4,885.78 SAR.Current price is: 4,592.63 SAR. excl. VAT Save 293.15 SAR

On backorder

Request a Quote

Original price was: 2,995.48 SAR.Current price is: 2,815.75 SAR. excl. VAT