APC EPDU1132M Metered Rack PDU 0U
A 7360 VA single-phase metered rack PDU with real-time remote monitoring through Web, SNMP and CLI. Vertical 0U mounting and mixed C13/C19 outlets suit planned rack installations.
Original price was: 2,474.63 SAR.2,326.15 SARCurrent price is: 2,326.15 SAR. excl. VAT
Available on backorder
RISYS can programme and prepare devices before delivery. Contact us for quantity and project details.
Wholesale and project supply — up to 45% off











Up to 45% off wholesale supply.
Overview
APC EPDU1132M combines single-phase rack power distribution with real-time remote monitoring. Its 7360 VA capacity makes it a candidate for cabinets where the operating team needs electrical distribution and visibility from beyond the equipment room. The distinguishing choice is the metered approach: this is the family member to assess when remote oversight is part of routine operations. Web, SNMP and Command Line Interface access give the IT team several ways to include the unit in its management workflow. For a Saudi business managing communications or server cabinets across a site, selection should bring the monitoring requirement together with the actual supply, outlet mix and physical rack arrangement before the purchase is approved.
APC EPDU1132M and remote operations
Real-time remote monitoring supports checking the installation without requiring every review to begin at the cabinet. Web access suits browser-based management, SNMP provides a route into a compatible monitoring environment, and the Command Line Interface accommodates teams that work through a command-based administration process. Decide who will manage the PDU and how it will fit the site’s network practices during deployment planning. Remote visibility is useful only when someone has responsibility for reviewing it, so include the unit in the operating handover alongside the equipment it supplies.
Check the single-phase electrical fit
This metered PDU accepts 200 V, 208 V or 230 V input, with a 32 A input current limit and a specified 230 V output. The frequency is 50/60 Hz, and the input connector is IEC 60309 32 A 2P + E. Its load capacity is 7360 VA. Have the electrical contractor assess the intended supply connection against these requirements while the equipment team prepares its load schedule. Matching the input connection and checking the connected demand are separate tasks; both must be settled before the cabinet layout is treated as ready for service.
Plan the equipment connections
There are 20 IEC 60320 C13 outlets and 4 IEC 60320 C19 outlets. Allocate them according to the power leads required by the installed equipment, keeping a clear record of which device uses each connection. A mixed outlet arrangement helps accommodate different connector requirements within the same rack, but the load plan must still respect the unit’s electrical limits. When a device is replaced, review its demand and lead type together. This avoids treating a physically suitable outlet as sufficient evidence that a proposed cabinet change is acceptable.
Mount beside the equipment space
The 0U body is designed for vertical side mounting, allowing the equipment mounting area to remain available. Height is 1175 mm, width is 62 mm and depth is 44.4 mm; net weight is 3.72 kg. These dimensions should be checked against the cabinet’s side clearance and the routes taken by equipment leads. The cable length is 2.99 m. Trace that route to the supply point before choosing the final mounting location, including the bends and routing space needed within the cabinet’s cable management arrangement.
Applications and family positioning
A facilities team overseeing an office server room can assess this model when it needs remote monitoring as part of cabinet operations. A logistics or retail IT team can consider the same capability where communications cabinets are reviewed centrally. In a security equipment room, its relevance depends on matching the installed devices to the electrical supply and outlet types. EPDU1132B addresses basic distribution within this family, while EPDU1132M adds the metered operating approach. EPDU1216M is a separate option to examine when the supply design calls for a three-phase arrangement. Choose the electrical architecture before deciding that similar-looking rack units are interchangeable.
Environmental planning and service records
The operating range is -5 to 45 °C with relative humidity from 5 to 95%. Check the environment at the mounting location rather than relying only on a room reading away from the equipment. Storage temperature extends from -25 to 65 °C, so distinguish project storage conditions from those required once the cabinet is running. The warranty is 12 months. Keep the outlet allocation, supply identification and management responsibility together in the handover record. That combination gives later maintenance work a useful starting point when the equipment population or the site’s monitoring workflow changes.
Package Contents
- Installation guide
- User manual
- Toolless mounting kit
- Vertical mounting brackets
Technical Specifications
- Brand
- APC
- Warranty
- 1 Year
- Model
- EPDU1132M
- Mounting
- RACK-MOUNTED
- Power
- 7360 VA
Frequently Asked Questions
How can the PDU be managed?
Management interfaces include Web, SNMP and Command Line Interface, with real-time remote monitoring.
What is the electrical capacity?
Load capacity is 7360 VA with a 32 A input current limit and single-phase input.
Which output connections are fitted?
It provides 20 IEC 60320 C13 outlets and 4 IEC 60320 C19 outlets.
What space does it need?
The vertical side-mounted 0U body measures 1175 mm high, 62 mm wide and 44.4 mm deep.

APC UPS systems keep servers and network cabinets running through outages and unstable mains, and the wider APC range extends into the racks, power distribution and sensors around them. APC began in the United States as American Power Conversion and
Browse brand productsDelivery across Saudi Arabia
Clear warranty
Some devices or frequencies may require a permit or approval depending on the intended use and the regulations in force in the Kingdom. Requirements are clarified before project orders are fulfilled.
Customer Reviews
No ratings yet for this product
Only logged in customers who have purchased this product may leave a review.
Related Products
APC APDU9959EU3 Switched Rack PDU, 16A 230V, IEC309 Cord
On backorder
APC AP4421A Rack Automatic Transfer Switch 1U 10A
On backorder
APC EPDU1116S Switched Rack PDU 16A, 20 C13 and 4 C19
On backorder
APC ER7PDUBRKTS Single-Width PDU Mounting Bracket Kit
On backorder





Reviews
There are no reviews yet.