ZKTeco ZK-SC103 RFID Standalone Access Control Terminal
Standalone RFID access control powered by DC 12V, with an LCD and connections for the lock, alarm, exit and door sensor. Supports 30,000 ID cards and 50,000 transactions; Mifare and HID Prox are optional.
345.00 SAR excl. VAT
Available on backorder
RISYS can programme and prepare devices before delivery. Contact us for quantity and project details.
Wholesale and project supply — up to 45% off











Up to 45% off wholesale supply.
Overview
ZKTeco SC103 is a standalone RFID access controller for a card-led entrance design, with DC 12V power and an LCD. Its selection starts with a practical question: does the site want staff to use ID cards at the door, with connections for the surrounding entrance hardware? For a Saudi office, service facility or administrative entrance, this gives the security team a focused basis for planning credentials, wiring and daily operation. The controller combines card storage, transaction storage and several communication interfaces. Assess the electrical supply and card technology together with the door connections, so procurement reflects the entrance being built and the way the facilities team intends to run it.
ZKTeco SC103: build around ID cards
The controller supports ID card authentication, with Mifare and HID Prox offered as optional card technologies. An organisation with existing staff cards should establish which technology it uses before selecting the configuration. That decision belongs early in procurement because a card-based workflow depends on matching the credentials to the chosen reader configuration. For a new installation, agree the card policy with the team issuing credentials, then use that policy consistently when specifying the controller and organising staff enrolment.
SC103 accommodates 30,000 ID cards and 50,000 transactions. The card database relates to the credentials enrolled for access, while transaction capacity relates to stored activity. Evaluate each against the planned user population and entrance use. A large card population does not itself describe how often the entrance will be used, so operations should also consider record-handling routines. Assign responsibility for keeping the card population current as staff join, leave or change roles, and include that responsibility in the handover.
Connections at the door
Lock, alarm, exit and door sensor connections let the installer plan the controller alongside the hardware involved in the entrance. Review the lock connection with the door contractor, the exit connection with the intended departure procedure and the door sensor connection with the opening being monitored. Include the alarm connection in the security wiring review. Mapping these connections before installation helps different contractors work to an agreed door design rather than making independent assumptions about the same entrance.
The LCD provides a local display at the controller. Consider the position of the unit in relation to the people presenting cards and the staff responsible for local operation. At an employee entrance serving a Saudi commercial building, the practical requirement is a clear card-use routine that reception, security and facilities can explain consistently. In an industrial administration area, the same planning should account for the teams who manage credentials and the contractors who maintain door hardware.
Network and serial integration planning
Communication options include TCP/IP, RS485 and USB host, with Wiegand input/output. The serial interface is specified as RS232/485. Have the installer identify the interface required by the intended system and map the corresponding cable route. Wiegand direction also deserves explicit review when connecting other access equipment. Treat the network and serial choices as parts of the site design, with the security and network teams agreeing where the controller connects and who owns each installation task.
Choosing SC103 within the family
SC103 suits a selection centred on card credentials and a DC 12V installation. ProFAC brings face and RFID authentication into the comparison when facial matching is part of the entrance brief. SC503 offers a card-based alternative with a doorbell interface among its door connections. These distinctions help procurement focus on the required entry process and peripheral wiring. Compare the functions needed at the particular opening, including whether a doorbell connection matters, before settling on a model.
For SC103 deployment, coordinate the DC 12V supply with the lock, alarm, exit and sensor wiring plan. Confirm the selected card technology, identify the communication interface and arrange a handover covering credential administration and transaction handling. This puts the power requirement, card workflow and connected entrance hardware into the same installation plan.
Technical Specifications
- Brand
- ZKTeco
- Authentication Method
- ID card; optional Mifare/HID Prox
- Capacity
- 30,000 ID cards; 50,000 transactions
- Connectivity
- TCP/IP, RS485, USB host; Wiegand input/output
- Device Type
- RFID standalone access controller
- Display
- LCD
- Model
- ZK-SC103
- Power
- DC 12V
Frequently Asked Questions
What power does SC103 require?
SC103 uses DC 12V power.
Does it support Mifare and HID Prox?
ID card authentication is standard; Mifare and HID Prox are optional configurations.
What are its storage capacities?
It supports 30,000 ID cards and 50,000 transactions.
Which door hardware connections are provided?
SC103 has connections for a lock, alarm, exit and door sensor.
Which communication interfaces does it offer?
Interfaces include TCP/IP, RS485, USB host and Wiegand input/output, with RS232/485 specified for serial communication.

Browse ZKTeco access control and time attendance equipment in one place: face and fingerprint terminals, door controllers, card readers, electric locks, hotel locks and vehicle barriers for offices, hotels and compounds across Saudi Arabia. ZKTeco is a Chinese biometrics manufacturer
Browse brand productsDelivery across Saudi Arabia
Clear warranty
Some devices or frequencies may require a permit or approval depending on the intended use and the regulations in force in the Kingdom. Requirements are clarified before project orders are fulfilled.
Customer Reviews
No ratings yet for this product
Only logged in customers who have purchased this product may leave a review.
Related Products
ZKTeco ZK-QR600-V-E QR and EM-Marine RFID Reader
On backorder
ZKTeco ZK-WRF100 MF Wireless Mifare Access Reader
On backorder
ZKTeco ZK-SpeedFace-M4 Face Access Control Terminal
On backorder
ZKTeco ZK-InBio260Pro Two-Door Biometric Access Panel
On backorder






Reviews
There are no reviews yet.