APC SRV72BP-9A 72V 1296Wh VRLA UPS Battery Pack
An APC external UPS battery pack holding two strings of six 12 V, 9 Ah sealed lead-acid blocks for a 72 V, 1296 Wh reserve with no electrolyte to top up.
Original price was: 3,470.56 SAR.3,262.33 SARCurrent price is: 3,262.33 SAR. excl. VAT
Available on backorder
RISYS can programme and prepare devices before delivery. Contact us for quantity and project details.
Wholesale and project supply — up to 45% off











Up to 45% off wholesale supply.
Overview
The APC SRV72BP-9A is the middle step in the SRV external battery range, and for many mid-sized UPS installations it is the balanced choice: a 72 V pack storing 1296 Wh, enough to make a real difference to backup time without moving up to the high-voltage strings at the top of the range. Inside are two strings of six 12 V, 9 Ah blocks, all of the sealed, maintenance-free, valve-regulated lead-acid (VRLA) type. Sealed construction means there is no electrolyte to top up and no routine watering, which keeps upkeep down to periodic checks and eventual replacement. Before ordering, confirm in your UPS documentation that the battery input calls for a 72 V external pack and that this part number is listed, because an external battery must match the UPS voltage exactly.
How the APC SRV72BP-9A works with your UPS
The pack connects to the UPS battery input with the battery cable supplied in the box. From then on the UPS treats it as additional battery: when the grid drops, the load runs on the combined energy of the internal battery and the external pack. The 1296 Wh figure is the number to bring to the runtime tables in the UPS documentation, since the actual minutes depend on the load connected. That extra time is what lets a site wait out a generator start, finish writing CCTV footage to disk, or shut servers down in sequence instead of losing them mid-operation.
Saudi deployments suited to a 72 V pack
Medium-sized equipment rooms are its natural home: the IT room of a school or a university faculty building, the comms room of a bank branch, the network closet of a hospital department, the server rack behind a hotel front office, or a factory control room with SCADA workstations, CCTV recorders and access-control controllers. These are sites where the UPS is sized above a desk-side unit but below a data-centre system, and where adding a battery pack is a practical way to gain backup minutes without replacing the UPS. Sealed VRLA construction keeps maintenance simple on sites without a dedicated battery technician, but heat still shortens battery life, so keep the pack in an air-conditioned space through the Saudi summer.
SRV72BP-9A within the SRV battery family
Read the range as three voltage tiers. The SRV36BP-9A, listed at 36 V, 648 VAh, serves UPS units with a low-voltage battery input. The SRV240BP-9A, listed at 240 V, 2160 VAh, serves units built around a high-voltage string. The SRV72BP-9A covers the middle tier. The SRV72RLBP-9A carries the same SRV72 designation, so check which of the two part numbers your UPS manual names before ordering; the decision follows the UPS design, not the bigger number.
Deployment notes
Position the pack where the supplied battery cable reaches the UPS battery connector without strain, and follow the connection order given in the user manual. Leave clearance around it for airflow and inspection. Because VRLA blocks are sealed, routine care comes down to keeping the room cool, watching the battery status shown by the UPS, and recording the installation date so the replacement can be budgeted before the blocks reach the end of their service life.
Package Contents
- Battery pack
- User manual
- Battery cable
Technical Specifications
- Brand
- APC
- Battery Details
- Sealed maintenance-free valve-regulated lead-acid
- Model
- SRV72BP-9A
- Power
- 1296 Wh
Frequently Asked Questions
What voltage and capacity does the APC SRV72BP-9A offer?
It runs at 72 V and stores 1296 Wh of energy.
What batteries are inside the SRV72BP-9A?
Two strings of six 12 V, 9 Ah blocks, all sealed, maintenance-free, valve-regulated lead-acid (VRLA).
Does the SRV72BP-9A need routine maintenance?
Its VRLA blocks are sealed, so there is no electrolyte to top up. Keep the room cool, watch the battery status on the UPS and track the installation date for replacement planning.
How does it compare with the SRV36BP-9A?
The SRV36BP-9A is listed at 36 V, 648 VAh for a low-voltage UPS battery input. The SRV72BP-9A runs at 72 V, and each pack only suits a UPS designed for its voltage.

APC UPS systems keep servers and network cabinets running through outages and unstable mains, and the wider APC range extends into the racks, power distribution and sensors around them. APC began in the United States as American Power Conversion and
Browse brand productsDelivery across Saudi Arabia
Clear warranty
Some devices or frequencies may require a permit or approval depending on the intended use and the regulations in force in the Kingdom. Requirements are clarified before project orders are fulfilled.
Customer Reviews
No ratings yet for this product
Only logged in customers who have purchased this product may leave a review.
Related Products
APC BVX2200LI Tower UPS 2200 VA
On backorder
APC SRVL2KRIRK Online UPS 2000VA Lithium-ion
On backorder
APC SMV1000I Line Interactive UPS 1000 VA
On backorder
APC SMT1500IC Smart-UPS Uninterruptible Power Supply
On backorder





Reviews
There are no reviews yet.