APC AP8760 Locking C19 to C20 Power Cord, 3 m
Factory-finished locking power cord with a C19 connector and an IEC 60320 C20 plug, 3 m long, for linking rack equipment to C19 outlets with no on-site wiring.
Original price was: 345.06 SAR.324.36 SARCurrent price is: 324.36 SAR. excl. VAT
Available on backorder
RISYS can programme and prepare devices before delivery. Contact us for quantity and project details.
Wholesale and project supply — up to 45% off











Up to 45% off wholesale supply.
Overview
The APC AP8760 is a locking power cord that joins a C19 connector to an IEC 60320 C20 plug, so both ends arrive finished and the cord goes into service the moment it is unpacked. Its place is inside the rack: the C20 plug goes into a C19 outlet on a PDU or UPS, and the locking C19 end goes into the C20 inlet of the equipment being powered. Because neither end needs wiring, there is no electrician visit and no separate plug to source, which keeps the cost of each connection down when a rack needs several of them. The locking C19 connector stays seated when servers are slid out on rails or cable bundles are rerouted, and the 3 m length covers the full height of a rack. For dense C19 equipment, the APC AP8760 is the balanced everyday choice in this range.
How the APC AP8760 behaves in a live rack
C19 and C20 are the high-current members of the IEC 60320 connector family, found on rack PDUs, UPS outputs, blade chassis, storage arrays and large network switches. In a busy rack the weak point is rarely the cord itself but the joint: a standard C19 relies on friction, and a tug from a cable tie or a server rail can partly unseat it, which is enough to drop a power supply without anyone noticing until an alarm fires. The locking C19 on this cord holds until its lock is released, so maintenance on neighbouring equipment does not disturb the connection. The C20 end is the standard plug that fits any C19 outlet, so the cord can be moved between PDUs and UPS units as a rack is reorganised.
AP8760 or AP8759: which supply end you need
The AP8759 shares the locking C19 end but leaves its supply end rewireable, to be terminated on site to a wall socket, industrial connector or terminal, and that flexibility costs installation time. The AP8760 is the cord to order when the supply point is already a C19 outlet, for example one of the C19 outlets on the metered AP8853. As a working rule, cords that stay inside the rack are AP8760s, and the one cord that has to reach the building supply is the AP8759.
Use cases across Saudi sectors
Data centres and server rooms
Colocation halls in Riyadh, Jeddah and Dammam, and the server rooms of banks and telecom operators, run racks fed from PDUs with C19 outlets. The AP8760 connects blade enclosures, storage shelves and core switches to those outlets, and its locking end protects dual-corded equipment during the frequent moves, additions and changes these rooms go through.
Security and surveillance control rooms
Command centres for CCTV and access control in government buildings, airports, hospitals and giga-project sites usually host video management servers and storage in UPS-backed racks. A cord that cannot be knocked loose behind a recorder protects video retention as much as any software setting does.
Industrial and energy sites
In control rooms at petrochemical, water and power facilities, racks are serviced by rotating crews. Finished cords with locking ends reduce the chance of a half-seated or wrongly reconnected plug after a shift change.
Deployment notes
Check that the equipment being powered has a C20 inlet and that the PDU or UPS has a free C19 outlet; this cord does not suit C13 and C14 equipment. Route the cord along the rack’s vertical cable manager and secure it without putting tension on the locking connector. To unplug, release the lock on the C19 end before pulling, since forcing a locked connector can damage the inlet. The cord is covered by a 24-month warranty.
Package Contents
- Locking C19 to C20 power cord
Technical Specifications
- Brand
- APC
- Warranty
- 2 Years
- Model
- AP8760
Frequently Asked Questions
What are the two ends of the APC AP8760?
A locking C19 connector on one end and an IEC 60320 C20 plug on the other, both factory-finished.
Where is the AP8760 typically used?
Inside the rack, to connect equipment with a C20 inlet to a C19 outlet on a PDU or UPS, such as the C19 outlets on the metered AP8853.
How long is the cord?
It is 3 m long.
Does it need an electrician to install?
No, both ends are finished. If the supply point is a wall socket or an industrial connector, the AP8759 with its rewireable end is the right cord.
What warranty does it carry?
The cord is covered by a 24-month warranty.

APC UPS systems keep servers and network cabinets running through outages and unstable mains, and the wider APC range extends into the racks, power distribution and sensors around them. APC began in the United States as American Power Conversion and
Browse brand productsDelivery across Saudi Arabia
Clear warranty
Some devices or frequencies may require a permit or approval depending on the intended use and the regulations in force in the Kingdom. Requirements are clarified before project orders are fulfilled.
Customer Reviews
No ratings yet for this product
Only logged in customers who have purchased this product may leave a review.
Related Products
APC BVX2200LI Tower UPS 2200 VA
On backorder
APC SRT1000RMXLI 1000VA Online Smart-UPS, 2U Rackmount
On backorder
APC SMX3000RMHV2U 3 kVA Smart-UPS, Rack/Tower Convertible
On backorder
APC SMT1500IC Smart-UPS Uninterruptible Power Supply
On backorder





Reviews
There are no reviews yet.