APC E3SBT4 UPS Battery String
An APC UPS battery string supplied as one complete assembly, for restoring or extending the backup reserve of a UPS in a single, orderly change.
Original price was: 3,880.62 SAR.3,647.78 SARCurrent price is: 3,647.78 SAR. excl. VAT
Available on backorder
RISYS can programme and prepare devices before delivery. Contact us for quantity and project details.
Wholesale and project supply — up to 45% off











Up to 45% off wholesale supply.
Overview
The APC E3SBT4 is a UPS battery string: the battery assembly a UPS draws on the moment mains power fails, supplied as one complete string rather than as loose blocks. Within the APC battery family it sits in the middle ground of coverage and price, a whole-string part for sites that want to restore or extend the backup reserve of their UPS in one planned change instead of chasing individual battery failures. Buying the string as a unit matters in practice: every battery in it starts service together, ages together and is tested together, so the UPS works from a balanced bank rather than new blocks wired beside tired ones. For a facilities or IT manager, the E3SBT4 is the part that turns a UPS whose battery test has started to fail back into dependable protection for the equipment behind it.
What the APC E3SBT4 does on site
A UPS holds its load on battery for as long as the string can supply it. That time is not fixed: it depends on how much equipment the UPS is carrying and on how many strings it has connected, so a lightly loaded UPS gets far more minutes from the same string than one running near its limit. Where a UPS accepts more than one string, adding an E3SBT4 is the way to lengthen the bridge to a standby generator; the number of strings is set by the UPS itself, so plan from its documentation. Between outages the UPS keeps the string charged and reports its condition through its own battery test.
Where Saudi sites use it
Server rooms in banks and insurers, the branch networks of retail chains, telecom shelters, hospital IT floors and the control rooms of industrial plants in Jubail and Yanbu all rely on UPS systems to hold equipment until generators take over. In each of them the battery string is the part that wears out, and keeping a matching spare string on the shelf shortens the time a site runs unprotected after a failed test. Batteries age faster in heat, so the string belongs in an air-conditioned room, with extra attention at sites in the Eastern Province and other hot regions during summer.
E3SBT4 next to the E3SBTH4 and E3SOPT007
The E3SBTH4 is the sibling string built from VRLA battery modules, suited to buyers who plan their battery bank module by module. The E3SBT4 is the direct whole-string choice when the requirement is simply to replace or add a string on a UPS that already calls for it. The E3SOPT007 is not a battery at all: it is a wall-mounted battery breaker box that sits on the circuit between the batteries and the UPS, and it complements a string rather than replacing one.
Before you install
Confirm that your UPS model takes the E3SBT4 before ordering. Battery strings are heavy, so plan the lifting and the route into the room in advance. Fit the string with the UPS in the safe state its documentation describes, run a battery test once it is connected to confirm the UPS recognises and charges it, and record the installation date on the string so the next replacement can be scheduled rather than discovered.
Technical Specifications
- Brand
- APC
- Model
- E3SBT4
Frequently Asked Questions
What is the APC E3SBT4?
It is an APC UPS battery string: the complete battery assembly a UPS runs on when mains power fails, supplied as one unit.
Why replace a whole string instead of individual batteries?
Every battery in a new string starts service together and ages together, so the UPS works from a balanced bank rather than new batteries wired beside worn ones.
How long will the E3SBT4 keep my equipment running?
Runtime depends on the load the UPS is carrying and on how many strings it has connected; a lightly loaded UPS runs much longer on the same string.
How does the E3SBT4 differ from the E3SOPT007?
The E3SBT4 is a battery string, while the E3SOPT007 is a wall-mounted battery breaker box placed on the circuit between the batteries and the UPS.

APC UPS systems keep servers and network cabinets running through outages and unstable mains, and the wider APC range extends into the racks, power distribution and sensors around them. APC began in the United States as American Power Conversion and
Browse brand productsDelivery across Saudi Arabia
Clear warranty
Some devices or frequencies may require a permit or approval depending on the intended use and the regulations in force in the Kingdom. Requirements are clarified before project orders are fulfilled.
Customer Reviews
No ratings yet for this product
Only logged in customers who have purchased this product may leave a review.
Related Products
APC SRV10KRILRK Online UPS with Rack Rails
On backorder
APC SMX3000RMHV2U 3 kVA Smart-UPS, Rack/Tower Convertible
On backorder
APC SMX3000HVNC 3kVA Smart-UPS with Network Card
On backorder
APC SRV10KRIRK Online Rack UPS 10 kVA
On backorder





Reviews
There are no reviews yet.