APC E3SUPS15KHB2 15 kVA Three-Phase UPS, Internal Batteries
A 15 kVA, 15 kW APC three-phase UPS delivered ready to run, with two internal 7Ah VRLA battery strings on a 240 V battery bus and room for a third.
Original price was: 27,055.08 SAR.25,431.78 SARCurrent price is: 25,431.78 SAR. excl. VAT
Available on backorder
RISYS can programme and prepare devices before delivery. Contact us for quantity and project details.
Wholesale and project supply — up to 45% off











Up to 45% off wholesale supply.
Overview
APC E3SUPS15KHB2 is the balanced middle of the APC three-phase family: a 15 kVA, 15 kW UPS that arrives with its batteries installed. Two internal 7Ah VRLA battery strings run on a 240 V battery bus, and the frame accepts a third string, so stored energy can grow without adding a separate cabinet. It delivers more capacity than the E3SUPS10KHB2, which is rated 10 kW / 10 kVA. At the same time it sits in a much smaller rating class than the E3MUPS models, which makes it a practical fit for a technical room that has outgrown a small UPS but does not justify a heavy installation. Unlike the E3SUPS15KHB, which ships with empty battery slots, this model provides backup as soon as it is commissioned, with no separate battery purchase to coordinate between suppliers.
What the APC E3SUPS15KHB2 gives you on site
Capacity and batteries come in one delivery. The 15 kVA rating matches the 15 kW output, so the whole rating is usable as real power and the load list can be checked straight against 15 kW. The two fitted strings handle short interruptions and the gap before a generator takes over. Because this unit carries heavier loads than the E3SUPS10KHB2, its strings are drawn down faster when it runs near its limit. If your load sits close to 15 kW, or your generator transfer takes longer, plan on fitting the third 7Ah string from the start.
Typical Saudi deployments
Think of the data room of a mid-sized company in Riyadh or Jeddah, the IT and CCTV head-end of a hotel, the industrial-control servers and PLC panels of a production line, the diagnostic equipment network of a polyclinic, or the administration building of a government or municipal body. In each case the critical load has outgrown a small unit, and the team needs backup that is ready on delivery rather than a separate battery project. The dust filter in the box helps protect the unit in equipment rooms where dust gets in, provided it is cleaned regularly.
Choosing within the middle capacity step
E3SUPS15KHB2 or E3SUPS15KHB
The two models share a capacity step; the difference is how they are supplied. This model arrives with two fitted strings, while the E3SUPS15KHB arrives without batteries. Choose the E3SUPS15KHB2 for a unit that works from its first day, and the other if you already have a battery supplier or a separate budget line for batteries.
When to move down or up
If your load stays clearly under the E3SUPS10KHB2 rating of 10 kW / 10 kVA, that model covers it at lower cost. If you need wider headroom, the E3SUPS20KHB2 steps up to 20 kVA. For larger rooms, the E3SUPS30KHB2 is rated 30 kW / 30 kVA.
Installation and maintenance
The third string must match the fitted pair: 7Ah, VRLA and a 240 V battery bus, with no mixing of capacities or ages. Leave service space in front of the battery compartment and the dust filter, and keep the installation guide with the site documents. Size the upstream breaker and cabling for a 15 kVA three-phase load according to local electrical practice, and have a qualified electrician make the connection. Watch the room temperature as well: VRLA batteries age faster in hot rooms, and good cooling protects the backup time you paid for.
Package Contents
- Dust filter
- Installation guide
Technical Specifications
- Brand
- APC
- Battery Details
- VRLA
- Model
- E3SUPS15KHB2
- Power
- 15 kVA
- Ups Power
- 15 kW
Frequently Asked Questions
What is the power rating of the APC E3SUPS15KHB2?
It is rated 15 kVA with a 15 kW output, so the full rating is available as real power.
How many battery strings does it hold?
It ships with two internal 7Ah VRLA strings and accepts up to three strings in total.
What is the battery voltage?
It runs on a 240 V battery bus, which any added string must match.
How does it differ from the E3SUPS15KHB?
Both share a capacity step, but this model arrives with batteries fitted, while the E3SUPS15KHB ships without batteries.

APC UPS systems keep servers and network cabinets running through outages and unstable mains, and the wider APC range extends into the racks, power distribution and sensors around them. APC began in the United States as American Power Conversion and
Browse brand productsDelivery across Saudi Arabia
Clear warranty
Some devices or frequencies may require a permit or approval depending on the intended use and the regulations in force in the Kingdom. Requirements are clarified before project orders are fulfilled.
Customer Reviews
No ratings yet for this product
Only logged in customers who have purchased this product may leave a review.
Related Products
APC SRVL2KRILRK Lithium-ion UPS 2000 VA
On backorder
APC SRV10KRI Online UPS 4U Rackmount
On backorder
APC SRV6KIL Tower UPS 6 kVA External Battery
On backorder
APC SMT1500IC Smart-UPS Uninterruptible Power Supply
On backorder





Reviews
There are no reviews yet.