APC E3SUPS40KHB2 40 kVA Three-Phase UPS with Batteries
A 40 kW / 40 kVA APC three-phase UPS delivered complete, with 4 internal 7Ah VRLA battery strings on a 240 V bus already fitted, so backup is in place from day one.
Original price was: 43,611.86 SAR.40,995.15 SARCurrent price is: 40,995.15 SAR. excl. VAT
Available on backorder
RISYS can programme and prepare devices before delivery. Contact us for quantity and project details.
Wholesale and project supply — up to 45% off











Up to 45% off wholesale supply.
Overview
The APC E3SUPS40KHB2 brings 40 kW / 40 kVA of three-phase protection in a unit that is complete on delivery. Its 4 battery slots arrive filled with internal 7Ah modular VRLA strings on a 240 V battery bus, and no slots are left free, so the backup capability is part of the purchase rather than a second procurement. That makes it the choice for a facility whose load sits above the mid-range models, or that wants spare capacity for planned expansion, and that still prefers to receive, install and commission one finished system. For a project manager, it removes a supplier, a delivery and a coordination step from the critical path to handover, with enough capacity for a large data room or the security operations centre of a multi-department building.
A complete APC E3SUPS40KHB2 system in practice
The output rating is 40 kW, equal to the 40 kVA apparent rating, so the full capacity can be planned in watts. A load schedule of server racks, storage, core network switches, recorders for a large camera estate, and access-control and fire-alarm interface panels can be totalled and compared directly with 40 kW. Because the strings are already in their slots, the unit is ready to provide backup as soon as it is connected and commissioned, with no wait for a battery shipment.
Why the modular strings matter
VRLA batteries are affected by age and by room temperature, so the battery set will be renewed during the life of the installation. With the stored energy divided into 4 modular strings inside the unit’s own slots, that renewal is organised around the strings rather than one large block. Replace them as a matched set on the 240 V bus, using the same VRLA type, and do not mix new strings with old ones.
Saudi sites for a 40 kVA unit with batteries
Sites that suit this capacity include the main IT room of a specialist hospital, where electronic records, PACS workstations and the network must stay up; a data room serving a corporate headquarters tower in Riyadh’s financial district; the central security operations room of a large compound or hotel, with recorders for an extensive camera estate and access-control controllers; a distribution centre in the industrial zones of Jeddah or Dammam running warehouse-management servers, scanners and loading-dock systems; and municipal or ministry buildings where several departments share one protected board. It also suits sites far from city supply chains, where receiving a finished system in one delivery avoids a second trip for batteries.
E3SUPS40KHB2 against its siblings
The E3SUPS40KHB has the same 40 kW/40 kVA rating but arrives with its battery slots empty; it suits projects where batteries are bought under a separate package. The E3SUPS30KHB2 is rated 30 kW / 30 kVA and, like this model, ships with its battery strings fitted, so it is the step down for a smaller load. Above this level, the E3MUPS60KHS is rated 60 kVA / 60 kW and the E3MUPS80KHS is rated 80 kVA / 80 kW. Choose the E3SUPS40KHB2 when your load calls for this capacity and you want backup in place from the first day.
Installation and maintenance notes
Have the electrical designer size the upstream protection and cabling for a 40 kVA three-phase load according to local practice. When planning floor loading and handling, note that the unit’s listed weight does not include the battery weight; add the weight of the fitted strings before choosing a location or lifting equipment. Keep clear access to the battery slots for future replacement, keep the supplied dust filter installed and include it in routine cleaning, particularly where fine dust enters the plant room. Store the installation guide in the handover file, and entrust the connection and commissioning to a qualified electrician.
Package Contents
- Dust filter
- Installation guide
Technical Specifications
- Brand
- APC
- Battery Details
- VRLA
- Model
- E3SUPS40KHB2
- Power
- 40 kW / 40 kVA
- Ups Power
- 40 kW
Frequently Asked Questions
Does the APC E3SUPS40KHB2 come with batteries?
Yes. Its 4 battery slots arrive filled with internal 7Ah modular VRLA strings, and no slots are left free.
What is the battery voltage?
The internal strings operate on a 240 V battery bus.
What is its output rating?
The output is 40 kW, and the unit is rated 40 kW / 40 kVA.
How does it differ from the E3SUPS40KHB?
The E3SUPS40KHB carries the same power rating but arrives with its battery slots empty, while this model arrives with its strings fitted.
Does the listed weight include the batteries?
No. The unit's listed weight does not include the battery weight.

APC UPS systems keep servers and network cabinets running through outages and unstable mains, and the wider APC range extends into the racks, power distribution and sensors around them. APC began in the United States as American Power Conversion and
Browse brand productsDelivery across Saudi Arabia
Clear warranty
Some devices or frequencies may require a permit or approval depending on the intended use and the regulations in force in the Kingdom. Requirements are clarified before project orders are fulfilled.
Customer Reviews
No ratings yet for this product
Only logged in customers who have purchased this product may leave a review.
Related Products
APC SMX3000HVNC 3kVA Smart-UPS with Network Card
On backorder
APC SMT1500RMI2UC Smart-UPS 1500VA 2U Rack SmartConnect
On backorder
APC SRV10KRI Online UPS 4U Rackmount
On backorder
APC SRT1000RMXLI 1000VA Online Smart-UPS, 2U Rackmount
On backorder





Reviews
There are no reviews yet.