Wholesale & retail - B2B/B2C
Free site survey in Riyadh
Shipping across the Kingdom
Warranty on all products
BrandAPC

APC SBP6KRMI2U Service Bypass Panel, 32 A MBB Hardwire

A rack-installed APC service bypass panel rated 32 A with a 230 V input, make-before-break (MBB) transfer, a hardwired input and (4) IEC-320 C19 outlets for higher-draw equipment.

ModelSBP6KRMI2UMountingRack installation

Original price was: 4,720.76 SAR.Current price is: 4,437.51 SAR. excl. VAT

Available on backorder

WhatsApp Inquiry

RISYS can programme and prepare devices before delivery. Contact us for quantity and project details.

Wholesale and project supply — up to 45% off

Minimum order5 units

Shipping and delivery icon
Fast shipping
SMSA Express logoFedEx logoNAQEL Express logoDHL logo
Product warranty icon
Genuine warranty
All products carry a one-year authorised-agent warranty.
Secure payment icon
Secure payment
madaVisaMastercardApple Pay
B2B sales icon
B2B/B2C supply

Up to 45% off wholesale supply.

Overview

The APC SBP6KRMI2U is a rack-installed service bypass panel built for the heavier end of a UPS installation. It lets the team move the protected load onto utility power, take the UPS out of circuit for maintenance or replacement, and bring the load back afterwards. Its bypass is of the MBB type, make-before-break: the new path closes before the old one opens, so the transfer itself does not interrupt the equipment. Rated at 32 A with a 230 V input, it takes a hardwired supply and presents (4) IEC-320 C19 outlets, the connector used by higher-draw equipment. In the APC UPS accessories family it is the balanced step up for sites whose rack load needs more current and more C19 outlets than a lighter panel offers, while still installing in the rack itself next to the equipment it serves.

What MBB transfer means on the APC SBP6KRMI2U

On a panel without make-before-break transfer, moving the load between the UPS and the utility supply can involve a short break, and that is enough to reboot servers or drop storage systems. With MBB, both sources are connected for a moment during the changeover, so the load stays powered from start to finish. For the technician this means UPS maintenance, battery work or a full UPS swap can be done during the working day without a shutdown window for the equipment behind it. While the load sits on bypass it runs on utility power with no battery backup, so the work should still be scheduled at a time when a mains disturbance would cause the least harm.

Hardwired input and C19 outputs

A hardwire input means the SBP6KRMI2U is connected to the electrical distribution by fixed wiring rather than by a plug. That makes it a permanent part of the installation: it should be planned with the electrical contractor, fed from a circuit with protection suited to its 32 A rating, and installed by a qualified electrician in line with local regulations. On the output side, the (4) IEC-320 C19 outlets suit equipment that uses C19 cords, such as larger servers, storage systems and rack power distribution units.

Where it fits on Saudi sites

The SBP6KRMI2U suits server rooms and small data rooms where one rack carries a dense load: core banking equipment in regional bank offices, hospital information systems, network and telecom hubs on university campuses, government data rooms, and the head-office IT rooms of retail and logistics companies in Riyadh, Jeddah and Dammam. In these settings uptime targets leave little room for planned shutdowns, which is exactly what an MBB bypass is meant to avoid.

SBP6KRMI2U or SBP3000RMI?

The SBP3000RMI is the lighter option, rated at 16 A with 6 IEC C13 outlets and 1 C19 outlet, which suits a rack of mostly compact servers and network switches. The SBP6KRMI2U moves up to 32 A and dedicates all four of its outlets to C19, so it is the better match when several devices in the rack need C19 cords or when the total load exceeds what the SBP3000RMI can carry. If the need is on the battery side rather than bypass, the SRT010 is a different kind of accessory: a battery extension cable, not a switching panel.

Deployment notes

The SBP6KRMI2U ships with an installation guide, rack mounting brackets and a user manual. Reserve rack space close to the UPS so the connections stay short, and plan the hardwired input with your electrician before the panel arrives on site. Label the bypass positions clearly, write the transfer sequence into the site’s maintenance procedure, and make sure only trained staff operate the panel. Our team can confirm that it matches your UPS model and electrical arrangement before you order.

Package Contents

  • Installation guide
  • Rack mounting brackets
  • User manual

Technical Specifications

Brand
APC
Model
SBP6KRMI2U
Mounting
Rack installation

Frequently Asked Questions

What does MBB mean on the APC SBP6KRMI2U?

MBB stands for make-before-break: the bypass path closes before the previous path opens, so the load is not interrupted while it is moved between the UPS and utility power.

How is the SBP6KRMI2U connected to the supply?

It has a hardwired input, so it should be installed by a qualified electrician on a circuit with protection suited to its rating.

Which outlets does the SBP6KRMI2U provide?

It provides (4) IEC-320 C19 outlets.

What is its electrical rating?

It is rated at 32 A with a 230 V input.

Is the SBP6KRMI2U rack-mountable?

Yes. It is designed for rack installation and ships with rack mounting brackets, an installation guide and a user manual.

Brand
APC

APC UPS systems keep servers and network cabinets running through outages and unstable mains, and the wider APC range extends into the racks, power distribution and sensors around them. APC began in the United States as American Power Conversion and

Browse brand products
Shipping, Warranty and Regulatory

Delivery across Saudi Arabia

Clear warranty

Some devices or frequencies may require a permit or approval depending on the intended use and the regulations in force in the Kingdom. Requirements are clarified before project orders are fulfilled.

Customer Reviews

No ratings yet for this product

Reviews

There are no reviews yet.

Only logged in customers who have purchased this product may leave a review.

Related Products

APC

APC SRT1000RMXLI 1000VA Online Smart-UPS, 2U Rackmount

Model SRT1000RMXLI
2U rackmount1000VA1000W
Original price was: 4,680.82 SAR.Current price is: 4,399.97 SAR. excl. VAT Save 280.85 SAR

On backorder

Request a Quote
APC

APC SRVL2KRILRK Lithium-ion UPS 2000 VA

Model SRVL2KRILRK
Lithium-ionRack2000 VA
Original price was: 8,673.94 SAR.Current price is: 8,153.50 SAR. excl. VAT Save 520.44 SAR

On backorder

Request a Quote
APC

APC SMX3000RMHV2U 3 kVA Smart-UPS, Rack/Tower Convertible

Model SMX3000RMHV2U
2U rack3kVA
Original price was: 8,474.29 SAR.Current price is: 7,965.83 SAR. excl. VAT Save 508.46 SAR

On backorder

Request a Quote
APC

APC SRV1KI Online Tower UPS 1000 VA

Model SRV1KI
LCDTower1000 VA
Original price was: 1,875.02 SAR.Current price is: 1,762.52 SAR. excl. VAT Save 112.50 SAR

On backorder

Request a Quote

Original price was: 4,720.76 SAR.Current price is: 4,437.51 SAR. excl. VAT