APC SMC1500I-2UC Smart-UPS 1500 VA 900 W 2U Rack UPS
A 1500 VA / 900 W APC Smart-UPS in a 2U rack chassis with AVR, a graphic LCD and 4 IEC C13 outlets, for racks that need more capacity in the same space.
Original price was: 2,493.48 SAR.2,343.87 SARCurrent price is: 2,343.87 SAR. excl. VAT
Available on backorder
RISYS can programme and prepare devices before delivery. Contact us for quantity and project details.
Wholesale and project supply — up to 45% off











Up to 45% off wholesale supply.
Overview
APC SMC1500I-2UC is the Smart-UPS for a rack whose load has outgrown the 600 W of SMC1000I-2UC but that still has only 2U to spare. Its defining figure is 900 W of real power, from a 1500 VA rating on a 230 V supply, which gives a network or security cabinet room for a second switch, a larger NVR or an additional server without changing the rack layout. The chassis is a 2U rackmount format with 4 IEC C13 outlets, so the extra capacity comes from the unit’s rating, not from more sockets: it is aimed at fewer, heavier loads rather than many light ones. AVR handles everyday voltage variation, a graphic LCD shows status on the front panel, and USB and serial ports link it to a host for monitoring and shutdown, with SmartConnect available for remote status checks.
Why 900 W matters for APC SMC1500I-2UC buyers
UPS sizing usually goes wrong on the watt figure, not the VA figure. Modern switches, servers and recorders draw power with a high power factor, so it is the 900 W limit that sets how much equipment the unit can carry. In practice, that headroom lets a rack run at a comfortable share of capacity rather than close to its ceiling, which is where a UPS is most likely to raise overload alarms when a device surges at start-up.
The same headroom helps with planning. A rack designed today with spare capacity inside 900 W can absorb a camera expansion or an extra PoE switch next year without a UPS replacement. Because the unit keeps the 2U footprint, that growth path does not cost additional rack units either.
Day-to-day operation
While mains is present, AVR corrects moderate sags and swells on the 230 V input without drawing on the internal lead-acid battery, so the battery is kept for real outages. When mains fails, the connected loads move to battery to ride through the interruption or to shut down in order. The USB cable in the box connects the unit to the host that coordinates shutdown, the serial port remains for management systems that rely on it, and the graphic LCD gives on-site staff the unit’s status at a glance.
Saudi facilities with denser racks
SMC1500I-2UC suits racks where the load is concentrated: the main communications cabinet of a mid-sized office floor, a hotel network rack carrying core switching and the property management server, the IT closet of a hospital department, a fuel station or retail outlet where CCTV recording and POS servers share one cabinet, and the network rack of a factory control room. Wherever SMC1000I-2UC would be running close to its limit, this model restores the margin.
Choosing between SMC1000I-2UC, SMC1500I-2UC and SMC2000I
SMC1000I-2UC shares this unit’s rack chassis and outlet layout but stops at 600 W, so it is the better buy only when the rack load is clearly below that. SMC1500I-2UC raises the limit to 900 W in the same rack height. Beyond that, SMC2000I is rated at 1300 W for loads that 900 W cannot cover. If the installation has no rack at all, the tower SMC1000IC, rated at 600 W, carries more outlets but less capacity than SMC1500I-2UC.
Commissioning notes
The package includes rack-mounting brackets, an installation guide, a documentation CD, a USB cable and the internal lead-acid battery. Mount the unit low in the rack. Before connecting loads, list each device with its rated draw and confirm the total stays under 900 W, leaving margin for start-up surges. Use C14-ended cords for the 4 IEC C13 outlets; where more devices need protection than there are outlets, route them through a rack PDU fed from the UPS, inside the same 900 W budget. Feed the input from a dedicated 230 V circuit sized for the unit, connect the USB cable to the shutdown host, and record the outlet map in the rack documentation.
Package Contents
- Documentation CD
- Installation guide
- Rack-mounting brackets
- USB cable
- Internal lead-acid battery
Technical Specifications
- Brand
- APC
- Battery Details
- lead-acid
- Display
- graphic LCD
- Model
- SMC1500I-2UC
- Mounting
- rackmount 2U
- Power
- 900 W
- Ups Power
- 1500 VA
Frequently Asked Questions
What is the real power capacity of APC SMC1500I-2UC?
900 W, from a 1500 VA rating. Size the connected load against the 900 W figure.
How does it compare with SMC1000I-2UC?
SMC1000I-2UC and SMC1500I-2UC both use a 2U rack chassis with 4 IEC C13 outlets, but SMC1000I-2UC is rated at 600 W while SMC1500I-2UC is rated at 900 W.
What is included for rack installation?
Rack-mounting brackets and an installation guide ship in the box, together with a documentation CD, a USB cable and the internal lead-acid battery.
How is the unit monitored?
Through USB or serial communication, with a graphic LCD on the front panel and SmartConnect support.

APC UPS systems keep servers and network cabinets running through outages and unstable mains, and the wider APC range extends into the racks, power distribution and sensors around them. APC began in the United States as American Power Conversion and
Browse brand productsDelivery across Saudi Arabia
Clear warranty
Some devices or frequencies may require a permit or approval depending on the intended use and the regulations in force in the Kingdom. Requirements are clarified before project orders are fulfilled.
Customer Reviews
No ratings yet for this product
Only logged in customers who have purchased this product may leave a review.
Related Products
APC BVX700LUI UPS with IEC Sockets
On backorder
APC SCL500RMI1UC Lithium-Ion 400W 1U Rackmount UPS
On backorder
APC SRV1KI Online Tower UPS 1000 VA
On backorder
APC SRV10KRILRK Online UPS with Rack Rails
On backorder





Reviews
There are no reviews yet.