Grandstream GXW4104 FXO VoIP Gateway
An FXO VoIP gateway connecting 4 RJ11 FXO ports to a managed SIP platform over Ethernet.
Original price was: $373.12.$333.11Current price is: $333.11. incl. VAT
Available on backorder
RISYS can programme and prepare devices before delivery. Contact us for quantity and project details.
Wholesale and project supply — up to 45% off

Fast shipping




Genuine warranty

Secure payment





B2B/B2C supply
Up to 45% off wholesale supply.
Overview
The Grandstream GXW4104 is an FXO VoIP gateway for bringing analogue public-network lines into a SIP-based communications environment. Its role is to terminate physical FXO circuits, map them to the planned SIP service, and give administrators a controlled bridge between legacy telephony and the IP network. A Saudi buyer should match the gateway to the exact number of analogue lines and simultaneous calls required at the site. Network addressing, codec policy, fax behavior, DTMF method, power, mounting, and recovery procedures also belong in the design. The GXW4104 is therefore a migration and integration component, not a general-purpose desk endpoint.
Grandstream GXW4104 in practical service
The GXW4104 can support offices, hotels, clinics, schools, warehouses, and branch sites that retain analogue trunks while operating a SIP platform. Each connected line should be documented by carrier circuit, gateway port, inbound destination, outbound rule, and failover expectation. Administrators should decide how unanswered calls, busy conditions, caller identification, and emergency routing will behave before cutover. The GXW4104 should be tested with the actual carrier line and PBX because successful registration alone does not prove complete call flow. A written port map makes later troubleshooting much faster.
Verified GXW4104 specifications
The GXW4104 ports is 4 RJ11 FXO ports. Confirm this GXW4104 specification against the PBX, carrier lines, network, and operating plan before installation.
The GXW4104 concurrent calls is 4. Confirm this GXW4104 specification against the PBX, carrier lines, network, and operating plan before installation.
The GXW4104 connectivity is Dual RJ45, 10/100 Mbps. Confirm this GXW4104 specification against the PBX, carrier lines, network, and operating plan before installation.
The GXW4104 power is 12 VDC adapter output; 100-240 VAC, 50-60 Hz input. Confirm this GXW4104 specification against the PBX, carrier lines, network, and operating plan before installation.
The GXW4104 mounting is Wall or desktop. Confirm this GXW4104 specification against the PBX, carrier lines, network, and operating plan before installation.
The GXW4104 sip accounts is 4. Confirm this GXW4104 specification against the PBX, carrier lines, network, and operating plan before installation.
The GXW4104 voice codecs is G.711, G.723, G.726 (40/32/24/16), G.729A/B/E, G.728, iLBC. Confirm this GXW4104 specification against the PBX, carrier lines, network, and operating plan before installation.
The GXW4104 fax is T.38 Group 3 relay up to 14.4 kbps; auto-switch to G.711 pass-through. Confirm this GXW4104 specification against the PBX, carrier lines, network, and operating plan before installation.
The GXW4104 signaling media is SIP RFC 3261; RTP/RTCP; SRTP. Confirm this GXW4104 specification against the PBX, carrier lines, network, and operating plan before installation.
The GXW4104 dtmf is In-audio, RFC2833 and/or SIP INFO. Confirm this GXW4104 specification against the PBX, carrier lines, network, and operating plan before installation.
The GXW4104 qos is DiffServ, TOS, 802.1p/Q VLAN. Confirm this GXW4104 specification against the PBX, carrier lines, network, and operating plan before installation.
The GXW4104 operating temperature is 0-40°C. Confirm this GXW4104 specification against the PBX, carrier lines, network, and operating plan before installation.
The GXW4104 storage temperature is -10-60°C. Confirm this GXW4104 specification against the PBX, carrier lines, network, and operating plan before installation.
The GXW4104 operating humidity is 10-90% RH non-condensing. Confirm this GXW4104 specification against the PBX, carrier lines, network, and operating plan before installation.
The GXW4104 certifications is FCC and CE. Confirm this GXW4104 specification against the PBX, carrier lines, network, and operating plan before installation.
Voice, fax, and signaling checks
The GXW4104 must be commissioned around the codecs and signaling methods approved for the organization. Test inbound and outbound speech, DTMF to automated attendants, transfer paths, caller release, and sustained calls. If fax is required, test the actual fax devices and destination paths under the selected relay or pass-through behavior. Quality-of-service settings should align with the network design rather than being enabled in isolation. Security and media settings should also match the SIP platform. Record the working profile so a replacement GXW4104 can be restored consistently.
Position within the gateway family
The GXW4104 should be compared with GXW4104, GXW4108 mainly on FXO port count and concurrent-call capacity. Choose the smaller chassis when it covers the active analogue circuits with sensible room for the approved plan. Choose the larger sibling when more lines must terminate at the same site. Avoid buying unused ports without a migration reason, but do not undersize the gateway if all carrier lines may be active together. The correct model is the one that maps cleanly to the circuit inventory and expected call load.
Installation and operations
Place the GXW4104 where analogue, Ethernet, and power cables can be labeled and protected. Confirm wall or desktop support, ventilation, electrical backup, grounding practices, and access for maintenance. During acceptance, simulate power and network recovery, test every FXO port, and verify the final routing table. Add the GXW4104 to the asset register with its IP address, PBX identity, circuit map, and support owner. The package contents cover the device, Ethernet connection, and power adapter, while the project remains responsible for carrier wiring and prepared network service.
Buying decision
Choose the GXW4104 only after reconciling the analogue-line inventory with port count, simultaneous calls, SIP accounts, codec requirements, fax use, and network policy. Include configuration, carrier coordination, testing, documentation, and support ownership in the purchase plan. When the port map and cutover procedure are ready, the GXW4104 provides a structured path for connecting existing FXO service to an IP communications system.
Package Contents
- Device unit
- Ethernet cable
- 12 V universal power adapter
Technical Specifications
- Brand
- Grandstream
- Model
- GXW4104
- Power
- 12 VDC adapter output; 100-240 VAC, 50-60 Hz input
- Connectivity
- Dual RJ45, 10/100 Mbps
- Ports
- 4 RJ11 FXO ports
- Mounting
- Wall or desktop
- Sip Accounts
- 4
- Concurrent Calls
- 4
Frequently Asked Questions
How many ports does the GXW4104 have?
The GXW4104 has 4 RJ11 FXO ports.
How many concurrent calls are supported?
The GXW4104 supports 4 concurrent calls.
What mounting options are supported?
The GXW4104 supports Wall or desktop placement.

Grandstream
Grandstream provides VoIP, IP PBX, IP phones, networking, Wi-Fi and unified communication solutions for businesses.
Browse brand productsShipping, Warranty and Regulatory
Delivery inside Riyadh
Clear warranty
Some devices or frequencies may require a permit or approval depending on the intended use and the regulations in force in the Kingdom. Requirements are clarified before project orders are fulfilled.
Customer Reviews
No ratings yet for this product
Only logged in customers who have purchased this product may leave a review.
Related Products
Grandstream GXW4248 FXS VoIP Gateway
On backorder
Grandstream HT818 Analog Telephone Adapter
On backorder
Grandstream HT814 Analog Telephone Adapter
On backorder
Grandstream UCM6208 IP PBX with Eight FXO Ports
On backorder









Reviews
There are no reviews yet.