ZKTeco EX-802 Door Exit Button with NO/COM Contact
A press-operated door opening button with a normally open NO/COM contact and maximum DC 36 V, 3 A rating. Its panel uses flame-retardant ABS material.
Original price was: 45.00 SAR.43.00 SARCurrent price is: 43.00 SAR. excl. VAT
Available on backorder
RISYS can programme and prepare devices before delivery. Contact us for quantity and project details.
Wholesale and project supply — up to 45% off











Up to 45% off wholesale supply.
Overview
The ZKTeco EX-802 is a press-operated door exit button for a door circuit that accepts a normally open NO/COM contact. Its maximum rating is DC 36 V, 3 A, making circuit matching the starting point for selection. For a facilities manager, its purpose is straightforward: provide a physical point where a user presses to request door opening. The flame-retardant ABS panel forms the user-facing part of that arrangement. This is the accessory to assess when the project calls for a manual exit request, whether equipping a door or replacing a button with the same contact arrangement. Its role differs from a backup battery because it handles a door-opening request within the connected system.
ZKTeco EX-802 contact operation in practice
The NO designation means normally open, while COM identifies the common terminal. Pressing the button changes the contact state so that a compatible connected circuit can respond to the opening request. Before installation, the technician should identify the relevant input on the door system and confirm that it expects this contact arrangement. During commissioning, test the normally open NO/COM contact through the actual door circuit. That check connects the physical action the user performs with the response the installed system needs to produce.
Treat the voltage and current rating as limits when reviewing the proposed connection. Compare the connected circuit with the maximum DC 36 V, 3 A rating before making the connection. For maintenance teams, separating contact operation from the rest of the door system also helps troubleshooting. Check whether a press changes the contact state, then assess the connected input and door response. This gives the technician a practical sequence for locating an operating fault rather than replacing the button before understanding the circuit.
Where to consider it in Saudi facilities
An administrative office can assess this button for departure from a staff area where the door design calls for a press-operated exit request. Educational facilities and warehouse work areas can make the same assessment for compatible door circuits. The relevant decision is the function required at that particular doorway. Review the normal departure route, the position where users will reach the button, and access for later inspection. These considerations help place the control within the daily movement of staff through the building.
The operating temperature range is -10°C to 55°C, and the operating humidity range is 0% to 95%. Check that temperatures at the proposed button position stay within -10°C to 55°C, especially where a doorway connects areas with different temperatures. A building’s overall use does not establish the conditions at every door. Check the installation position itself before finalizing the work. This review is particularly useful when the door sits close to a building entrance or serves an area with different environmental conditions from the adjoining office space.
Panel material and repeated operation
The panel uses flame-retardant ABS material. Include the flame-retardant ABS panel when reviewing door accessory material requirements for the project. The MCBF figure is 100,000 operations, providing a reference for comparing repeated-operation requirements. Facilities teams can use actual doorway traffic to shape inspection routines, checking the button action, panel condition, and connections during maintenance visits. A functional test at the installed door remains valuable because the user’s exit request also depends on how the connected circuit responds to the contact.
Positioning against the backup accessory
The EX-802 serves a different job from the ZK-UFace Battery: the button provides a door-opening request, while the battery addresses backup power. Choose according to the operational task being purchased. For a replacement button, begin with the existing contact arrangement and circuit limits, then verify operation after installation. For a new door, include the button connection in the door wiring plan and the press test in the handover procedure. Recording that connection gives the facilities team a useful reference when servicing the doorway later.
Technical Specifications
- Brand
- ZKTeco
- Device Type
- Door opening push button
- Model
- EX-802
- Power
- Max DC 36V,3A
Frequently Asked Questions
How is the opening request triggered?
The button operates by pressing and uses a normally open NO/COM contact for a compatible door circuit.
What is its maximum electrical rating?
The maximum rating is DC 36 V, 3 A. Match the connected circuit to these limits before installation.
What is the panel material?
The panel uses flame-retardant ABS material. Its MCBF figure is 100,000 operations.
What are the operating environmental limits?
The operating temperature is -10°C to 55°C and the operating humidity is 0% to 95%.

Browse ZKTeco access control and time attendance equipment in one place: face and fingerprint terminals, door controllers, card readers, electric locks, hotel locks and vehicle barriers for offices, hotels and compounds across Saudi Arabia. ZKTeco is a Chinese biometrics manufacturer
Browse brand productsDelivery across Saudi Arabia
Clear warranty
Some devices or frequencies may require a permit or approval depending on the intended use and the regulations in force in the Kingdom. Requirements are clarified before project orders are fulfilled.
Customer Reviews
No ratings yet for this product
Only logged in customers who have purchased this product may leave a review.