ZKTeco InBio460 Four-Door Biometric Access Control Panel

Control four doors using fingerprint and card authentication, with TCP/IP, RS-485 and optional Wi-Fi connectivity. InBio460 provides 12 reader connections and operates on 9.6V–14.4V DC.

Authentication MethodFingerprint and cardCapacity30,000 card holders; 3,000 fingerprints; 100,000 event recordsConnectivityTCP/IP, RS-485, optional Wi-FiDevice TypeBiometric Access Control PanelModelInbio460Power9.6V–14.4V DC

1,870.00 SAR excl. VAT

Available on backorder

WhatsApp Inquiry

RISYS can programme and prepare devices before delivery. Contact us for quantity and project details.

Wholesale and project supply — up to 45% off

Minimum order10 units

Shipping and delivery icon
Fast shipping
SMSA Express logoFedEx logoNAQEL Express logoDHL logo
Product warranty icon
Genuine warranty
All products carry a one-year authorised-agent warranty.
Secure payment icon
Secure payment
madaVisaMastercardApple Pay
B2B sales icon
B2B/B2C supply

Up to 45% off wholesale supply.

Overview

ZKTeco InBio460 brings four-door control into a site design that needs careful coordination of power, reader wiring and communication routes. Its 9.6V–14.4V DC supply range gives the installer a defined electrical requirement, while TCP/IP, RS-485 and optional Wi-Fi provide communication choices to assess against the premises. The useful purchasing question is how those connections fit the door layout, rather than whether a panel carries a Pro suffix. Fingerprint and card authentication support a credential plan for staff and other authorised users. For a Saudi facilities team comparing controllers, this model deserves consideration when several controlled entrances belong to the same project and the installer needs to account for both the field connections and the route back to the network.

ZKTeco InBio460 across a four-door layout

The four-door scope can suit an office area with separate departmental entrances or a facility where staff access is divided between distinct zones. Begin by naming each controlled doorway and identifying the authentication method intended there. This makes the controller selection a response to the physical building. It also gives the security team a clear basis for reviewing the installer proposal before readers and other field equipment are ordered.

Fingerprint and card authentication offer different ways to identify authorised users. Decide how each method fits the groups moving through the premises and how enrolment will be organised. A card-based population and a fingerprint population require separate capacity checks. For a business with changing staff assignments, keeping that distinction visible in the access plan helps the administrator prepare credentials according to the actual working arrangement.

Matching credentials and event activity

InBio460 stores 30,000 card holders and 3,000 fingerprints. Compare each limit with the corresponding enrolment requirement, including the people expected to use the controlled area. These figures describe credential storage; they should be considered alongside the door schedule rather than used to estimate how many entrances the panel can handle. A project can have a broad card population while its biometric enrolment requirement remains more concentrated.

Its event storage accommodates 100,000 records. The practical value of that space depends on how frequently the controlled doors are used and how the operations team reviews access events. Plan review procedures around expected site activity instead of equating the record count to a fixed retention period. A quieter departmental door and a busy staff entrance can contribute very different volumes to the same operational review process.

Reader and field connection planning

The reader provision comprises 12 connections: eight RS-485 and four 26/34-bit Wiegand interfaces. Match readers against the relevant interface before committing to a device schedule. The Wiegand format is a useful detail when checking the proposed reader arrangement, while the RS-485 connections belong in the field wiring plan. Reader provision should be mapped to the controlled doors so the installer and buyer share the same understanding of the layout.

There are 12 inputs and eight outputs for the field connection schedule. Have the integrator identify the intended use of each required connection and review the resulting allocation with the door plan. This is especially useful when the access project involves several contractors: a written connection schedule gives the facilities team something concrete to review during installation and again during acceptance of the completed works.

Communication and supply decisions

TCP/IP and RS-485 connectivity let the project team assess the communication arrangement against the site infrastructure. Wi-Fi is optional, so treat it as a configuration choice when defining the order and installation scope. Decide the intended communication route early enough for the network team and security installer to coordinate their work. Choosing optional wireless connectivity still leaves the door wiring and DC supply as parts of the installation plan.

For a Saudi distribution office or an administrative building, review this model around the entrances that require control and the available routes for connections. Compare InBio460 with InBio-260 Pro and InBio-460 Pro using door coverage, authentication capacity and the proposed wiring design. Its DC supply range is an installation requirement, rather than a reason to assume superiority over another model. Confirm the electrical arrangement and test the chosen reader paths as part of handover.

Technical Specifications

Brand
ZKTeco
Authentication Method
Fingerprint and card
Capacity
30,000 card holders; 3,000 fingerprints; 100,000 event records
Connectivity
TCP/IP, RS-485, optional Wi-Fi
Device Type
Biometric Access Control Panel
Model
Inbio460
Power
9.6V–14.4V DC

Frequently Asked Questions

How many doors and readers does InBio460 support?

It controls four doors and provides 12 reader connections.

Is Wi-Fi standard?

Wi-Fi is optional. Connectivity also includes TCP/IP and RS-485.

What are its credential and event capacities?

Capacity is 30,000 card holders, 3,000 fingerprints and 100,000 event records.

What are the reader interfaces and supply range?

It has eight RS-485 and four 26/34-bit Wiegand reader interfaces, and uses 9.6V–14.4V DC.

Brand
ZKTeco

Browse ZKTeco access control and time attendance equipment in one place: face and fingerprint terminals, door controllers, card readers, electric locks, hotel locks and vehicle barriers for offices, hotels and compounds across Saudi Arabia. ZKTeco is a Chinese biometrics manufacturer

Browse brand products
Shipping, Warranty and Regulatory

Delivery across Saudi Arabia

Clear warranty

Some devices or frequencies may require a permit or approval depending on the intended use and the regulations in force in the Kingdom. Requirements are clarified before project orders are fulfilled.

Customer Reviews

No ratings yet for this product

Reviews

There are no reviews yet.

Only logged in customers who have purchased this product may leave a review.

Related Products

ZKTeco

ZKTeco ZK-InBio260Pro Two-Door Biometric Access Panel

Model ZK-INBIO260PRO
Fingerprint and card60TCP
1,720.00 SAR excl. VAT

On backorder

Request a Quote
ZKTeco

ZKTeco ZK-SF200 Fingerprint Attendance and Access Terminal

Model ZK-SF200
Fingerprint1TCP
174.76 SAR excl. VAT

On backorder

Request a Quote
ZKTeco

ZKTeco ZK-QR600-V-E QR and EM-Marine RFID Reader

Model ZK-QR600-V-E
IP65EM-Marine RFID card a...Wiegand
445.00 SAR excl. VAT

On backorder

Request a Quote
ZKTeco

ZKTeco ZK-SC103 RFID Standalone Access Control Terminal

Model ZK-SC103
ID card30TCP
345.00 SAR excl. VAT

On backorder

Request a Quote

1,870.00 SAR excl. VAT