APC PDM3532IEC-560 Power Distribution Module, 560 cm
The longest of three APC power distribution modules: 560 cm of cable carrying a 400 V three-phase, 32 A circuit to a distant rack, ending in an IEC 309 32 A outlet.
Original price was: 3,460.55 SAR.3,252.92 SARCurrent price is: 3,252.92 SAR. excl. VAT
Available on backorder
RISYS can programme and prepare devices before delivery. Contact us for quantity and project details.
Wholesale and project supply — up to 45% off











Up to 45% off wholesale supply.
Overview
The APC PDM3532IEC-560 is the longest of the three power distribution modules offered here, with 560 cm of cable between its 32 A breaker and its single IEC 309 32 A outlet. That extra reach is the reason to choose it: a rack at the far end of a row, a cabinet across the aisle from the panel, or a route that climbs into overhead trays before dropping into the rack. It works on a 400 V three-phase supply rated at 50 Hz, carries a maximum line current of 32 A and lists its output at 230 V and at 400 V three-phase. Choosing a lead long enough at the outset avoids the worst workaround in a server room, which is extending a high-current circuit with an improvised joint. The grey assembly carries CE and VDE marks.
Reach and rating of the APC PDM3532IEC-560
A power distribution module of this kind turns a branch circuit into a catalogue item. Its 32 A breaker protects the run, the cable carries the three phases to the rack, and the IEC 309 32 A outlet presents a standard industrial connection at the far end. Nothing has to be terminated inside the cabinet, which keeps live electrical work out of rooms where IT staff are still installing equipment.
Length does not lower the rating: the module is specified for a maximum current draw of 32 A at 400 V three-phase over its full 560 cm. Each line of the supply can carry up to 32 A, so the rack has substantial capacity to work with, and loads can be balanced across the phases to keep each line inside the breaker rating. The rack PDU that plugs into the outlet must carry an IEC 309 32 A plug of the same configuration, because the keyed connector will not accept anything else.
A longer run also calls for more care in routing. Keep the cable in trays rather than across floor tiles, separated from data cabling where the site standard requires it, and label both ends so the circuit can be traced from panel to rack during audits and fault-finding.
Where Saudi projects need the longer run
Large data halls are the obvious home: government cloud and shared-services centres, the main data centres of banks and telecom operators, and colocation facilities in Riyadh, Jeddah and the Eastern Province, where one distribution panel may serve racks spread along a long row. The racks furthest from the panel are the ones this length is chosen for.
It also suits buildings where the power route is not a straight line: hospitals and universities converting existing spaces into IT rooms, airports and transport control centres where cable must follow fixed containment, and oil, gas and petrochemical sites whose control rooms route power overhead. In each case the extra cable absorbs bends and rises that a shorter lead could not.
How it compares with the PDM3532IEC-440 and PDM3532IEC-500
All three modules share the same electrical design and the same industrial outlet; the PDM3532IEC-440 and PDM3532IEC-500 simply stop sooner. That makes the comparison a question of route geometry rather than capacity. If the measured route fits one of the shorter modules with a sensible margin, take the shorter one, with less copper to coil, less weight in the tray and a tidier cabinet top. If it does not, the PDM3532IEC-560 is the module that reaches without a joint.
Ordering the longest length for every position to be safe works against a well-run room, because surplus cable piles up behind cabinets and obstructs cooling. The cleanest result comes from mixing the three lengths according to where each rack stands.
Deployment checklist
Before ordering, confirm a 400 V three-phase source with upstream protection specified by the site electrical engineer, an IEC 309 32 A plug of matching configuration on the equipment at the rack, and that the module’s 50 Hz rating suits the supply frequency of the feeding panel.
Measure the full path, including vertical drops and the distance inside the cabinet to the PDU inlet, and decide in advance where any slack will rest. The box holds an installation guide, the warranty term is 12 months, and the CE and VDE marks are available for consultant submittals.
Package Contents
- Installation guide
Technical Specifications
- Brand
- APC
- Warranty
- 1 Year
- Model
- PDM3532IEC-560
- Power
- 400 V 3 PHASES
Frequently Asked Questions
How long is the cable on the APC PDM3532IEC-560?
560 cm, the longest of the three lengths offered here, running between its 32 A breaker and its IEC 309 32 A outlet.
Does the longer cable reduce its rating?
No. It is specified for a maximum current draw of 32 A on a 400 V three-phase supply.
What frequency is it rated for?
50 Hz. Check this against the supply frequency of the feeding panel before installation.
Should I use it for every rack in a row?
No. Use it for racks the PDM3532IEC-440 and PDM3532IEC-500 cannot reach, since shorter leads avoid surplus cable that blocks cooling.

APC UPS systems keep servers and network cabinets running through outages and unstable mains, and the wider APC range extends into the racks, power distribution and sensors around them. APC began in the United States as American Power Conversion and
Browse brand productsDelivery across Saudi Arabia
Clear warranty
Some devices or frequencies may require a permit or approval depending on the intended use and the regulations in force in the Kingdom. Requirements are clarified before project orders are fulfilled.
Customer Reviews
No ratings yet for this product
Only logged in customers who have purchased this product may leave a review.
Related Products
APC AP4423A Rack Transfer Switch 1U 16A, 3700 VA
On backorder
APC AP7822B Metered Rack PDU, 32A, 2U, C13 and C19
On backorder
APC AP7921B Switched Rack PDU, 16 A, 1U, 8 C13 Outlets
On backorder
APC APDU9959EU3 Switched Rack PDU, 16A 230V, IEC309 Cord
On backorder





Reviews
There are no reviews yet.