APC PDM3516IEC-320 Power Distribution Module
Power distribution module with a 320 cm output cable, circuit monitoring and one IEC 309 16 A outlet. Its 400 V three-phase input and three-pole breaker belong in the electrical design review.
Original price was: 2,725.44 SAR.2,561.91 SARCurrent price is: 2,561.91 SAR. excl. VAT
Available on backorder
RISYS can programme and prepare devices before delivery. Contact us for quantity and project details.
Wholesale and project supply — up to 45% off











Up to 45% off wholesale supply.
Overview
APC PDM3516IEC-320 is a power distribution module for a planned connection using a 320 cm output cable. Its useful place in an equipment schedule is determined by how that run fits the room layout, where the receiving outlet connection sits and what electrical supply the project provides. The module combines an IEC 309 16 A outlet with circuit monitoring and one three-pole breaker. For a buyer balancing cable coverage with a specific distribution task, these details establish a practical selection brief. Confirm the route and circuit together, then assign the exact model to its destination. That makes the module part of a coordinated installation plan, with a defined connection for the electrical contractor and a clear circuit association for the operations team.
APC PDM3516IEC-320 and the intended cable path
The output cable measures 320 cm. Assess this length against the route the installer will use, rather than the distance drawn directly between equipment positions. Allow for the way the route approaches the receiving connection and passes surrounding equipment. The aim is to confirm that the chosen path can be served by this cable before committing the module to the equipment schedule. A measured route also gives procurement a clear reason for selecting this exact reference.
Agree the route with the people arranging the equipment in the room. A connection point can move during project coordination, so confirm the final position before installation starts. Record the start and destination of the planned run on the work instructions. When several power connections are being commissioned together, that description helps the installer associate the module with its intended equipment and gives the receiving team a consistent reference during handover.
Supply conditions and current limits
The module has a 400 V three-phase input and operates at 50 Hz. Both maximum line current and maximum current draw are 16 A. Review these ratings with the electrical designer against the supply arrangement and the load assigned to the circuit. The selection should reflect the intended operation of the connected equipment as well as the physical route. Keep the current limit visible in the installation documentation so future equipment changes can be assessed against the original circuit design.
The single IEC 309 16 A outlet needs a matching receiving connection. Settle that interface while coordinating the module with the equipment it will serve. The outlet type is an ordering and installation detail that should be understood by both the electrical contractor and the equipment supplier. Confirming it before delivery gives each party a precise connection to prepare, which is useful when separate contractors are responsible for the distribution side and the receiving equipment.
Circuit monitoring and maintenance preparation
Circuit monitoring supports attention to the assigned distribution circuit during operation. Connect that capability to practical handover documentation by identifying which equipment the module serves and where its cable runs. The installed module includes one three-pole breaker, which should appear in the circuit information used by the maintenance team. These details help staff reviewing the room understand the relationship between the module, its breaker and the destination connection without relying only on the physical appearance of the equipment.
The module has a grey finish. Use the exact model reference in equipment records and on installation paperwork so identification does not depend on colour. Before work begins, agree access to the module location and the receiving connection with site operations. Plan how the route will remain accessible when adjacent equipment is in place. This keeps the electrical connection coordinated with the room layout through installation, commissioning and subsequent maintenance work.
Family positioning and Saudi project use
Consider PDM3516IEC-260 and PDM3516IEC-1040 during the same model-selection review, with the assigned cable path guiding the final choice. Preserve the complete model reference in purchase requests and delivery checks. The APC distribution family also includes AP7820B and AP7821B; list each reference against its own scheduled duty so a general family description does not obscure the intended module selection.
In Saudi enterprise equipment rooms, commercial facilities and operations environments, assess this model where its input, current limits and outlet match the approved electrical design. The installation guide helps prepare the work, and the 12-month warranty belongs with the procurement handover. Retain the circuit assignment and cable destination alongside the model reference so the facilities team can review future changes against the installation that was actually commissioned.
Package Contents
- Power distribution module
- Installation guide
Technical Specifications
- Brand
- APC
- Warranty
- 1 Year
- Model
- PDM3516IEC-320
Frequently Asked Questions
What cable length should I use for route planning?
The output cable is 320 cm long. Compare that length with the complete route to the receiving connection, including the approach around equipment.
What electrical input does the module require?
The input is 400 V three-phase at 50 Hz. Maximum line current and maximum current draw are both 16 A.
What outlet and breaker are fitted?
The module has one IEC 309 16 A outlet and one three-pole breaker, with circuit monitoring.
What is the warranty period?
The warranty is 12 months. Keep the exact PDM3516IEC-320 model reference with the purchasing and installation documents.

APC UPS systems keep servers and network cabinets running through outages and unstable mains, and the wider APC range extends into the racks, power distribution and sensors around them. APC began in the United States as American Power Conversion and
Browse brand productsDelivery across Saudi Arabia
Clear warranty
Some devices or frequencies may require a permit or approval depending on the intended use and the regulations in force in the Kingdom. Requirements are clarified before project orders are fulfilled.
Customer Reviews
No ratings yet for this product
Only logged in customers who have purchased this product may leave a review.
Related Products
APC APDU9941 Switched Rack PDU 30A, 200V/208V
On backorder
APC AP8886 Metered Rack PDU, 32A Three-Phase 400V
On backorder
APC AP6015A 1U Rack PDU, 8 C13 Outlets, 15A Input
On backorder
APC AP7921B Switched Rack PDU, 16 A, 1U, 8 C13 Outlets
On backorder





Reviews
There are no reviews yet.