APC AP6015A 1U Rack PDU, 8 C13 Outlets, 15A Input
A 1U APC rack PDU with 8 IEC 60320 C13 outlets and an IEC 60320 C14 inlet, rated 100-240V at a maximum input current of 15A. It can be mounted horizontally or vertically.
Original price was: 295.05 SAR.277.35 SARCurrent price is: 277.35 SAR. excl. VAT
Available on backorder
RISYS can programme and prepare devices before delivery. Contact us for quantity and project details.
Wholesale and project supply — up to 45% off











Up to 45% off wholesale supply.
Overview
The APC AP6015A is a 1U rack PDU built for the smaller end of a power plan: 8 IEC 60320 C13 outlets fed through an IEC 60320 C14 inlet, with 100-240V input and a maximum input current of 15A. That 15A rating is what sets it apart within its family. It is sized for the load of a compact cabinet rather than a full server rack, and its C14 inlet keeps the supply connection on a standard IEC cord that is easy to source and replace. The horizontal 1U body can be fixed across a rack position or turned and mounted vertically, a choice the Zero U strips in the range do not give. For network closets, branch offices and security enclosures, it brings orderly power distribution without oversizing the feed, and one model covers sites on any supply within its 100-240V input range.
Two ways to mount the APC AP6015A
Mounted horizontally, the AP6015A occupies a single rack unit and presents its outlets across the width of the cabinet. That is the tidy option in a shallow wall-mounted enclosure with no side space for a vertical strip. Mounted vertically, it sits along the side of a frame or enclosure and leaves the rack positions free for equipment. Either way, a short body carrying eight outlets keeps cord runs short in a cabinet holding a router, a switch, a firewall, an NVR and a few accessories.
Typical Saudi deployments
Retail chains and bank branches across the Kingdom often run one small network cabinet per site; the AP6015A powers the edge switch, router and recorder there without the cost and bulk of a full-height strip. School and clinic IT rooms, guard houses at residential compounds and CCTV cabinets at warehouses and fuel stations follow the same pattern: a handful of devices on a modest circuit. Integrators rolling out a standard kit to dozens of sites benefit from a single compact PDU that works across 100-240V supplies.
How it compares with the AP6003A and AP6020A
The AP6015A is the lighter-duty option of the three. The AP6003A moves to a Zero U vertical strip with a larger outlet count and a higher maximum input current, aimed at densely populated server racks. The AP6020A is also a Zero U vertical strip with a C20 inlet, and the AP6020A is rated for 200-240 volt output, which suits racks already wired to that voltage band. Choose the AP6015A when the load is modest, rack or side space is tight, and a C14 cord connection is preferred.
Before installing
Keep the total connected load within the 15A maximum input current, and leave headroom for start-up surges from devices such as recorders with several drives. Feed the C14 inlet from a circuit rated accordingly, and settle on horizontal or vertical mounting before the cabinet is populated, so the outlets end up within reach of every power supply. The installation guide and safety guide supplied with the unit cover fixing and connection.
Package Contents
- Installation guide
- Safety guide
Technical Specifications
- Brand
- APC
- Model
- AP6015A
- Mounting
- 1U horizontal design; can be mounted horizontally or vertically
- Power
- 100-240V, max input current 15A
Frequently Asked Questions
Can the APC AP6015A be mounted vertically?
Yes. It is a 1U horizontal design that can be mounted either horizontally across a rack position or vertically along the side of a frame or enclosure.
What is the maximum input current of the AP6015A?
The AP6015A accepts 100-240V input with a maximum input current of 15A, so the connected load and the feeding circuit should stay within that rating.
How many outlets does the AP6015A have, and what inlet?
It has 8 IEC 60320 C13 outlets and is fed through an IEC 60320 C14 inlet.
Should I choose the AP6015A or the AP6003A?
Choose the AP6015A for small cabinets with a modest load. The AP6003A is a Zero U vertical strip with more outlets and a higher maximum input current, intended for fuller server racks.

APC UPS systems keep servers and network cabinets running through outages and unstable mains, and the wider APC range extends into the racks, power distribution and sensors around them. APC began in the United States as American Power Conversion and
Browse brand productsDelivery across Saudi Arabia
Clear warranty
Some devices or frequencies may require a permit or approval depending on the intended use and the regulations in force in the Kingdom. Requirements are clarified before project orders are fulfilled.
Customer Reviews
No ratings yet for this product
Only logged in customers who have purchased this product may leave a review.
Related Products
APC APDU9953 Switched Rack PDU, 32A 230V, 21 C13 + 3 C19
On backorder
APC AP8886 Metered Rack PDU, 32A Three-Phase 400V
On backorder
APC AP7821B Metered Rack PDU, 16A, 1U, 8 x C13
On backorder
APC AP4423A Rack Transfer Switch 1U 16A, 3700 VA
On backorder





Reviews
There are no reviews yet.