APC AP8886 Metered Rack PDU, 32A Three-Phase 400V
A metered, vertically mounted rack PDU that takes a 32 A, 400 V three-phase feed and spreads it across 30 IEC C13 and 12 IEC C19 outlets in a single strip.
Original price was: 9,311.73 SAR.8,753.03 SARCurrent price is: 8,753.03 SAR. excl. VAT
Available on backorder
RISYS can programme and prepare devices before delivery. Contact us for quantity and project details.
Wholesale and project supply — up to 45% off











Up to 45% off wholesale supply.
Overview
The APC AP8886 is the three-phase member of this rack PDU family: a metered strip that mounts vertically on the side of the rack and takes a 32 A feed at 400 V across three phases. Where the smaller strips in the family serve a handful of devices from one circuit, the AP8886 is sized for a fully populated cabinet, carrying 30 IEC 60320 C13 outlets and 12 IEC 60320 C19 outlets on one body. That mix lets a single strip feed everyday servers, switches and storage shelves on C13 while the C19 sockets take higher-draw equipment. Because it is metered, the load on the strip can be read rather than estimated, which matters when three phases have to be kept in balance. Side mounting leaves every horizontal rack unit free for equipment.
How the APC AP8886 works on site
A three-phase PDU changes how a cabinet is planned. Instead of running several single-phase circuits back to separate breakers, the facility team brings one 400 V three-phase circuit to the rack and lets the AP8886 distribute it. The 32 A rating sets the ceiling for that circuit, and the metering gives the operator a figure to compare against it during commissioning and whenever new equipment is added. With outlets split between C13 and C19 sockets, mixed loads share the strip without adapter cords.
Vertical side mounting keeps the strip out of the equipment space. The outlets run alongside the devices from the top of the rack to the bottom, so patch cords stay short and tidy, and the rear of the cabinet stays easy to reach when a device is serviced or swapped.
Where it fits in Saudi facilities
Colocation halls and enterprise data centres in Riyadh, Jeddah and the Eastern Province that already bring 400 V three-phase power to the rack rows are the natural home for the AP8886. Government entities, banks and telecom operators consolidating servers into high-density cabinets can run one strip per rack side instead of several smaller units. Hospitals and university campuses with central server rooms benefit from the metering when they need to show how much headroom remains before approving new systems. On large surveillance projects, a recording cabinet holding several NVRs and video-management servers is another fit, as long as the room has a three-phase supply.
Choosing between the AP8886 and its siblings
The deciding question is the supply available at the rack. If the room delivers a single-phase circuit, look instead at a model such as the AP9559, which takes a 16 A input through an IEC 60320 C20 connector. The AP9565 is a basic strip whose outlets are all C13, with no load metering. Choose the AP8886 when the cabinet has a 400 V three-phase supply, needs far more outlets than the AP9559 or AP9565 offer, and the operator wants load readings at the rack itself.
Deployment notes
The AP8886 needs a 400 V three-phase circuit rated for 32 A, which the site electrician should confirm before ordering. Mounting is vertical on the side of the rack, so check that the cabinet offers suitable side mounting space. The unit ships with rack mounting brackets, a serial configuration cable, an installation guide and a safety guide, and it carries a 24-month warranty.
Package Contents
- Installation guide
- Rack mounting brackets
- Serial configuration cable
- Safety guide
Technical Specifications
- Brand
- APC
- Warranty
- 2 Years
- Model
- AP8886
- Mounting
- Rack-mounted, vertical, side
- Power
- 32 A
Frequently Asked Questions
What power supply does the APC AP8886 need?
A 400 V three-phase circuit rated for 32 A.
How many outlets does the AP8886 have?
It carries 30 IEC 60320 C13 outlets and 12 IEC 60320 C19 outlets.
Does the AP8886 take up rack units?
It mounts vertically on the side of the rack, leaving the horizontal rack units free for equipment.
What warranty does the AP8886 carry?
It carries a 24-month warranty.

APC UPS systems keep servers and network cabinets running through outages and unstable mains, and the wider APC range extends into the racks, power distribution and sensors around them. APC began in the United States as American Power Conversion and
Browse brand productsDelivery across Saudi Arabia
Clear warranty
Some devices or frequencies may require a permit or approval depending on the intended use and the regulations in force in the Kingdom. Requirements are clarified before project orders are fulfilled.
Customer Reviews
No ratings yet for this product
Only logged in customers who have purchased this product may leave a review.
Related Products
APC AP7821B Metered Rack PDU, 16A, 1U, 8 x C13
On backorder
APC AP6020A Zero U Rack PDU, 13 C13 Outlets, C20 Inlet
On backorder
APC APDU9959NA3 Switched Rack PDU, 20A 208V, L620 Cord
On backorder
APC AP6032A Rack PDU, 4 C19 Outlets, 32A IEC 60309 Input
On backorder





Reviews
There are no reviews yet.