APC AP6003A Zero U Rack PDU, 14 C13 Outlets, 20A

A Zero U vertical rack PDU from APC with 14 IEC 60320 C13 outlets, fed through an IEC 60320 C20 inlet and rated 100-240V with a maximum input current of 20A.

ModelAP6003AMountingZero U vertical mounting designPower100-240V, max input current 20A

Original price was: 825.13 SAR.Current price is: 775.62 SAR. excl. VAT

Available on backorder

WhatsApp Inquiry

RISYS can programme and prepare devices before delivery. Contact us for quantity and project details.

Wholesale and project supply — up to 45% off

Minimum order15 units

Shipping and delivery icon
Fast shipping
SMSA Express logoFedEx logoNAQEL Express logoDHL logo
Product warranty icon
Genuine warranty
All products carry a one-year authorised-agent warranty.
Secure payment icon
Secure payment
madaVisaMastercardApple Pay
B2B sales icon
B2B/B2C supply

Up to 45% off wholesale supply.

Overview

The APC AP6003A is a Zero U rack PDU that puts 14 IEC 60320 C13 outlets on a vertical strip, fed through an IEC 60320 C20 inlet. It accepts 100-240V input with a maximum input current of 20A. Within APC’s rack power distribution range it sits at the balanced point: more outlets than a compact horizontal strip, mounted in the cabinet’s side space so it uses none of the equipment height, and a single, widely used inlet type at the supply end. For a buyer outfitting a standard server or network rack, that combination covers a full complement of C13-corded devices without stepping up to a larger or more specialised unit. The wide input range also means the same model can be specified for sites on different supply voltages, which makes it simpler to standardise spares across several buildings.

What the APC AP6003A does in a rack

A vertical Zero U strip mounts along the side of the cabinet rather than across a rack position. Every unit of height stays available for servers, switches, NVRs and storage, and because the outlets run the length of the strip, each device’s power cord reaches a nearby socket instead of being looped across the cabinet. With 14 C13 outlets, one strip can feed a typical mix of servers, switches and a firewall from one side of the rack, leaving the other side free for a second strip on a separate circuit where a redundant feed is required.

The C20 inlet is the higher-current style of the common IEC inlets, in keeping with the 20A maximum input current. The supply cord is selected to match the circuit and the upstream connection in each room.

Where it fits in Saudi facilities

In Saudi data halls and hosting suites, the AP6003A suits racks that are densely populated: hosting cabinets, enterprise server racks and storage arrays. Telecom and IT rooms in hospitals, universities and government buildings use it to power core switching and servers without giving up rack space to power equipment. Security integrators building CCTV head-ends for malls, residential compounds and industrial sites can run NVRs, video storage, PoE switches and the monitoring workstation from one strip. In oil, gas and utility control rooms, where cabinets are often filled to capacity, the Zero U format keeps every rack position free for process and network equipment.

Choosing between the AP6003A, AP6015A and AP6020A

Pick the AP6003A when the rack needs a high outlet count, a C20 feed and the 20A maximum input current, all without occupying rack height. The AP6015A is the compact alternative: a horizontal 1U strip with fewer outlets and a lower 15A maximum input current on the AP6015A, suited to a small network cabinet or a wall-mounted enclosure where a full-height vertical strip would not fit. The AP6020A shares the Zero U vertical layout and C20 inlet but carries a slightly shorter row of C13 outlets, and the AP6020A is rated for 200-240 volt output, so it belongs on sites already standardised on that voltage band.

Deployment notes

Size the upstream circuit and breaker for the 20A maximum input current and for the load actually connected, not for the number of outlets in use. Fix the strip in the cabinet’s vertical side space so the outlets face the power supplies of the installed equipment, and route the C20 supply cord to its feed without crossing the hot exhaust path. Where two strips are fitted for redundancy, take each from a separate circuit, so devices with two power supplies keep running if one feed is lost. The installation guide and safety guide in the box cover the mounting and connection steps.

Package Contents

  • Installation guide
  • Safety guide

Technical Specifications

Brand
APC
Model
AP6003A
Mounting
Zero U vertical mounting design
Power
100-240V, max input current 20A

Frequently Asked Questions

How many outlets does the APC AP6003A have?

It has 14 IEC 60320 C13 outlets arranged along a vertical Zero U strip, so each device in the rack can reach a nearby socket.

What input does the AP6003A use?

Power enters through an IEC 60320 C20 inlet. The unit accepts 100-240V input with a maximum input current of 20A, so the upstream circuit should be sized to that rating.

Does the AP6003A take up rack units?

No. It follows a Zero U vertical mounting design and fits in the cabinet's side space, leaving every rack position free for equipment.

When is the AP6015A a better choice than the AP6003A?

When the cabinet is small and the load is modest. The AP6015A is a horizontal 1U strip with fewer outlets and a 15A maximum input current on the AP6015A, while the AP6003A is the vertical strip for fuller racks.

Brand
APC

APC UPS systems keep servers and network cabinets running through outages and unstable mains, and the wider APC range extends into the racks, power distribution and sensors around them. APC began in the United States as American Power Conversion and

Browse brand products
Shipping, Warranty and Regulatory

Delivery across Saudi Arabia

Clear warranty

Some devices or frequencies may require a permit or approval depending on the intended use and the regulations in force in the Kingdom. Requirements are clarified before project orders are fulfilled.

Customer Reviews

No ratings yet for this product

Reviews

There are no reviews yet.

Only logged in customers who have purchased this product may leave a review.

Related Products

APC

APC ER7PDUBRKTS Single-Width PDU Mounting Bracket Kit

Model ER7PDUBRKTS
Original price was: 110.98 SAR.Current price is: 104.32 SAR. excl. VAT Save 6.66 SAR

On backorder

Request a Quote
APC

APC EPDU1116S Switched Rack PDU 16A, 20 C13 and 4 C19

Model EPDU1116S
0U16 A3.7kW
Original price was: 3,695.59 SAR.Current price is: 3,473.85 SAR. excl. VAT Save 221.74 SAR

On backorder

Request a Quote
APC

APC AP8886 Metered Rack PDU, 32A Three-Phase 400V

Model AP8886
2 YearsRack-mounted32 A
Original price was: 9,311.73 SAR.Current price is: 8,753.03 SAR. excl. VAT Save 558.70 SAR

On backorder

Request a Quote
APC

APC AP7820B Metered Rack PDU, 1U, 8 x C13 Outlets

Model AP7820B
2 Years1U208V
Original price was: 2,025.32 SAR.Current price is: 1,903.80 SAR. excl. VAT Save 121.52 SAR

On backorder

Request a Quote

Original price was: 825.13 SAR.Current price is: 775.62 SAR. excl. VAT