APC AP8716R Angled C20 to C19 Power Cord Kit, 1.8 m
Six 1.8 m C20 to C19 jumper cords in left-angle and right-angle versions, rated 16 A and for operation from 0 to 75 °C, for crowded or wide racks.
Original price was: 955.15 SAR.897.84 SARCurrent price is: 897.84 SAR. excl. VAT
Available on backorder
RISYS can programme and prepare devices before delivery. Contact us for quantity and project details.
Wholesale and project supply — up to 45% off











Up to 45% off wholesale supply.
Overview
APC AP8716R is a kit of six 1.8 m jumper cords, split between left-angle and right-angle versions, each joining a C20 input to a C19 output. It runs longer than the AP8712S and AP8714S kits and is the angled-connector option among them. The angled heads are the point. In a crowded rack, a straight connector body sticking out of a PDU or server inlet can block a neighbouring outlet, clash with a cable arm or press against a door; turning the cord to the left or to the right lets it run flat along the equipment instead. The extra length lets the same cord reach equipment towards the far edge of the cabinet. Each cord carries a maximum current draw of 16 A, and the kit is rated for operation from 0 to 75 °C, which matters in hot-aisle conditions.
How the APC AP8716R angled cords help
Left-angle and right-angle versions exist because PDUs and equipment are not all oriented the same way. On a vertical PDU the outlets face into the rack, and the direction a cord needs to turn depends on which side of the cabinet the equipment sits. On a server, the inlet may sit next to a fan module, a handle or a second power supply. Having both directions in one kit means the installer can pick the version that sends the cord away from the obstruction, rather than bending a straight cord hard against its strain relief. That reduces stress on the connector and keeps the rear of the rack readable when someone needs to trace a feed back to its outlet.
Rated operating and storage conditions
The AP8716R is specified for operation between 0 and 75 °C at relative humidity from 20 to 80 %, with an operating altitude of up to 10000 ft. For storage the temperature range widens to between -25 and 75 °C, with the same 20 to 80 % humidity band and a storage altitude of up to 15240 m. In practice this means the cords tolerate the elevated temperatures found behind high-density equipment in a hot aisle, and spare kits can be held in a warehouse or site store without special conditioning, provided humidity stays inside the stated band. Highland sites such as Abha and Taif sit comfortably within the operating altitude rating.
Where the AP8716R fits Saudi sites
Large colocation halls around Riyadh and Dammam run racks with high power density, where hot-aisle temperatures and crowded rear panels are everyday conditions; angled cords help keep outlets usable as equipment density climbs. Telecom switching rooms and edge sites across the Kingdom, including those in the southern highlands, often house mixed equipment from several vendors with inlets in different positions, which is exactly where a choice of left and right angles saves rework during installation. Hospital and university data rooms with wide cabinets and PDUs fixed on one side benefit from the 1.8 m reach, which lets a single cord serve equipment across the full width of the rack.
AP8716R or the AP8712S and AP8714S?
The AP8712S and AP8714S supply locking cords at 0.6 m and 1.2 m respectively, aimed at short and mid-length runs where connector retention is the priority. The AP8716R answers a different problem: reach across the cabinet and the direction in which the connector leaves the outlet. Choose it when measured runs exceed what the AP8714S covers, or when straight connector bodies would collide with adjacent outlets, handles or panels. Choose the AP8712S or AP8714S when the run is short and the main risk is a cord being knocked out during maintenance. Some racks justify a combination, with short cords near the PDU and angled long cords for the awkward far-side positions.
Installation notes for the AP8716R
Before installation, look at each PDU outlet and equipment inlet and decide which way the cord should leave the connector, then label the left-angle and right-angle cords for their positions before the rack is closed up. Measure the route through the cable managers, because a 1.8 m cord left with too much excess becomes an airflow obstruction of its own. Confirm that each connected device draws no more than the 16 A rating, and that the PDU outlet and its circuit can carry the combined load. The kit is not rack-mountable, so plan strap points along the vertical manager. The cords hold CCC, CSA, PSE and VDE approvals and are UL listed, and the kit is covered by a 24-month warranty.
Package Contents
- Left-angle jumper cord × 3
- Right-angle jumper cord × 3
Technical Specifications
- Brand
- APC
- Warranty
- 2 Years
- Model
- AP8716R
- Mounting
- Not rack-mountable
Frequently Asked Questions
Why does the APC AP8716R include left-angle and right-angle cords?
Outlets and inlets face different directions depending on the PDU and the equipment. Having both angles lets the installer route each cord away from neighbouring outlets, handles or panels instead of bending a straight cord.
How long are the AP8716R cords?
Each of the six jumper cords is 1.8 m long, which suits wide racks and runs from a PDU to equipment at the far side of the cabinet.
What temperature range is the AP8716R rated for?
It is rated for operation from 0 to 75 °C and for storage from -25 to 75 °C, at relative humidity from 20 to 80 %.
What current can each AP8716R cord carry?
Each cord has a maximum current draw and maximum line current of 16 A, with an IEC 60320 C20 input and a C19 output.

APC UPS systems keep servers and network cabinets running through outages and unstable mains, and the wider APC range extends into the racks, power distribution and sensors around them. APC began in the United States as American Power Conversion and
Browse brand productsDelivery across Saudi Arabia
Clear warranty
Some devices or frequencies may require a permit or approval depending on the intended use and the regulations in force in the Kingdom. Requirements are clarified before project orders are fulfilled.
Customer Reviews
No ratings yet for this product
Only logged in customers who have purchased this product may leave a review.
Related Products
APC SMT2200IC Smart-UPS 2200VA 1980W Tower UPS
On backorder
APC SRV15KRILRK Online Rack UPS 15 kVA
On backorder
APC SRV6KIL Tower UPS 6 kVA External Battery
On backorder
APC SRV10KRILRK Online UPS with Rack Rails
On backorder





Reviews
There are no reviews yet.