APC AP8881 Metered Rack PDU, 3-Phase 11 kW, 36 C13 + 6 C19
A 0U APC NetShelter metered rack PDU for three-phase 400 V supplies, rated 11 kW at 16 A, with 36 C13 and 6 C19 outlets and a 1.82 m input cable with an IEC 60309 plug.
Original price was: 5,561.53 SAR.5,227.84 SARCurrent price is: 5,227.84 SAR. excl. VAT
Available on backorder
RISYS can programme and prepare devices before delivery. Contact us for quantity and project details.
Wholesale and project supply — up to 45% off











Up to 45% off wholesale supply.
Overview
The APC AP8881 is a metered rack PDU rated at 11 kW, and within the APC family it is the step up to three-phase power. It takes a 400 V three-phase supply at 16 A and distributes it as 230 V to its outlets, which is how a single cabinet feed can carry the load of a dense rack of servers and storage. Part of the NetShelter range, it mounts at 0U in the rear of the cabinet and carries 36 C13 outlets and 6 C19 outlets, a count that covers a heavily populated cabinet without additional strips in most layouts. Power arrives through one input cable, 1.82 m long, ending in an IEC 60309 16 A 3P + N + PE plug. As a metered unit it measures the load it carries, giving the operations team a clear view of how much of the 11 kW budget is already in use before anything new is installed.
How three-phase power shapes the APC AP8881 cabinet
Moving from one phase to three is what lifts the capacity: the same 16 A rating, applied across three phases of a 400 V supply, gives the AP8881 its 11 kW rating. For comparison, the single-phase AP8858EU3 is rated at 3.7 kW. In a cabinet holding blade chassis, GPU servers or storage arrays, that difference decides whether one PDU is enough or the cabinet needs several separate feeds. Each outlet still delivers 230 V, so standard IT equipment connects without any change. The trade-off is planning: three-phase loads should be spread evenly across the phases, so where each device is plugged in deserves the same attention as the outlet count. Metering helps here by showing the load the unit carries as devices are added.
Outlet layout for dense racks
The 36 C13 outlets take the standard power cords used by rack servers, switches, firewalls and video recorders. The 6 C19 outlets serve the larger connector found on chassis switches, storage controllers, blade enclosures and high-wattage servers. With dual-supply servers, a pair of AP8881 units, each on its own feed, lets every server draw from two independent sources, so the loss of one feed does not stop the equipment. Mounting at 0U keeps all the front rack space for equipment, which matters most in exactly the kind of high-density cabinet this unit is meant to serve.
Saudi use cases for the AP8881
Three-phase distribution down to the rack is common practice in large data centres, and the AP8881 suits colocation halls, cloud and hosting facilities, and the enterprise data centres of banks, telecom operators and energy companies across the Kingdom. University research clusters and government computing centres running dense compute or storage cabinets are a natural fit as well. For security integrators, the unit makes sense in the central video management rooms of airports, malls and city surveillance projects, where many recorders and storage servers share a few cabinets. In control buildings at refineries and utility plants, the industrial IEC 60309 plug matches the sockets these sites install for heavy loads.
AP8881 against its siblings
Choose the AP8881 when the cabinet is fed with three-phase power and the load exceeds what a single-phase strip can carry. The AP8858EU3 offers the same metered class in a single-phase format rated at 3.7 kW, with fewer outlets. The AP8853 sits between them at 7.4kW. The AP8886 is rated at 32 A. Sites that need still more capacity can look at the EPDU1232B, rated at 22 kW.
Deployment notes
The AP8881 needs a 400 V three-phase circuit at 16 A terminated in an IEC 60309 3P + N + PE socket, positioned within reach of the 1.82 m input cable. Because the cable is relatively short, fix the socket location, under the raised floor or on the tray directly above the cabinet, before the rack is placed. Confirm that the cabinet has 0U mounting provisions in its rear channel; the rack mounting brackets are in the box. The included serial configuration cable is used for initial setup, and the installation and safety guides should be read before a three-phase supply is energised, which is work for a qualified electrician. The unit carries a 24-month warranty.
Package Contents
- Installation guide
- Rack mounting brackets
- Serial configuration cable
- Safety guide
Technical Specifications
- Brand
- APC
- Warranty
- 2 Years
- Model
- AP8881
- Mounting
- 0U
- Power
- 11 kW
Frequently Asked Questions
What power supply does the APC AP8881 need?
A 400 V three-phase circuit at 16 A, with an IEC 60309 16 A 3P + N + PE socket for its input plug.
What voltage do the outlets deliver?
230 V, so standard IT equipment connects directly.
How many outlets does it have?
36 C13 outlets and 6 C19 outlets.
How long is the input cable?
1.82 m, on a single input cable, so the socket should be placed close to the cabinet.
Which product range does it belong to, and what is the warranty?
It is part of the APC NetShelter range and carries a 24-month warranty.

APC UPS systems keep servers and network cabinets running through outages and unstable mains, and the wider APC range extends into the racks, power distribution and sensors around them. APC began in the United States as American Power Conversion and
Browse brand productsDelivery across Saudi Arabia
Clear warranty
Some devices or frequencies may require a permit or approval depending on the intended use and the regulations in force in the Kingdom. Requirements are clarified before project orders are fulfilled.
Customer Reviews
No ratings yet for this product
Only logged in customers who have purchased this product may leave a review.
Related Products
APC AP7820B Metered Rack PDU, 1U, 8 x C13 Outlets
On backorder
APC APDU9959EU3 Switched Rack PDU, 16A 230V, IEC309 Cord
On backorder
APC AP4424A Rack Transfer Switch 2U 32A, 18 Outlets
On backorder
APC APDU9941 Switched Rack PDU 30A, 200V/208V
On backorder





Reviews
There are no reviews yet.