APC AP9877 Power Cord, IEC C20 to C19, 2.0 m
A 2.0 m APC power cord with an IEC C20 plug at the input end and an IEC C19 connector at the outlet end. It feeds equipment fitted with a C20 inlet from the C19 outlet of a rack PDU or UPS.
Original price was: 215.03 SAR.202.13 SARCurrent price is: 202.13 SAR. excl. VAT
Available on backorder
RISYS can programme and prepare devices before delivery. Contact us for quantity and project details.
Wholesale and project supply — up to 45% off











Up to 45% off wholesale supply.
Overview
The APC AP9877 is a 2.0 m power cord built on the larger IEC connector pair: an IEC C20 plug at the input end and an IEC C19 connector at the outlet end. That pairing is its place in APC’s rack power family. The C19 and C20 pair is fitted to equipment that draws more power than an ordinary switch, such as blade chassis, large storage arrays and high-density servers whose power supplies carry a C20 inlet. In a cabinet the AP9877 runs from a C19 outlet on the rack PDU or UPS, where its C20 plug seats, to the C20 inlet on the device, where its C19 connector seats. The cord weighs 0.36 kg, and that weight sits on the connectors at both ends, so it is worth planning how the cord will be supported along the rack before the equipment is energised.
What the APC AP9877 does in practice
A device fitted with a C20 inlet cannot take a standard IEC cord; it needs the larger connector at the equipment end. The AP9877 supplies that connection directly from a C19 outlet, which keeps the high-draw device on the PDU outlet that was sized for it and avoids adapters between the outlet and the inlet. Each connection made this way is a single cord from outlet to inlet, which is easier to trace and to audit than a chain of adapters.
Plan the cord paths before ordering. The 2.0 m length is the reach available between the C19 outlet and the device inlet, so measure the route along the cable manager rather than the straight-line distance between them.
Saudi use cases for the AP9877
The C19 and C20 pair appears wherever a site runs heavy rack equipment: colocation and enterprise data halls in Riyadh, Jeddah and Dammam, the core rooms of banks, telecom operators and government data centres, and the storage and virtualisation racks of hospitals and universities. In security projects it powers the large recording and storage servers behind the camera systems of malls, airports, industrial cities and residential compounds, where those servers carry power supplies with a C20 inlet. It is equally relevant when a UPS in the cabinet has a C20 inlet and is fed from a C19 outlet on the rack PDU.
The AP9877 against its siblings
The AP9870 is the standard cord of the family, built around an IEC 60320 C14 plug and rated 10 A, and it serves switches, recorders and servers fitted with the ordinary inlet. The AP9877 is the step up for equipment fitted with the larger C20 inlet. The AP9878 sits between the two, combining a large connector at one end with a standard plug at the other for cases where the outlet and the inlet belong to different size classes. When the device inlet is C20 and the PDU has a free C19 outlet, the AP9877 is the cord that matches both ends without an adapter.
Deployment notes
Count the C20 inlets in the cabinet and compare them with the free C19 outlets on the rack PDU before ordering, and reserve those outlets for the equipment that actually needs them. For devices with redundant power supplies, run one AP9877 from each supply to a separate PDU so the device keeps running on one feed if the other fails. Support the cord in the cable manager so its 0.36 kg weight is not left hanging from the inlet, and label both ends with the outlet number and the device name.
Package Contents
- Power cord C19 to C20 2.0m
Technical Specifications
- Brand
- APC
- Model
- AP9877
- Power
- IEC C20 input, IEC C19 outlet
Frequently Asked Questions
What connectors does the APC AP9877 have?
An IEC C20 plug at the input end and an IEC C19 connector at the outlet end. The C20 plug goes into a C19 outlet on a rack PDU or UPS, and the C19 connector goes into the C20 inlet on the device.
How long is the AP9877?
The cord is 2.0 m long.
How much does the AP9877 weigh?
It weighs 0.36 kg, so support it in the cable manager rather than letting it hang from the inlet.
Which equipment needs the AP9877?
Equipment whose power supply has a C20 inlet, such as blade chassis, large storage arrays and high-density servers, connected to a C19 outlet on the PDU or UPS.
How does the AP9877 differ from the AP9870?
The AP9870 is built around an IEC 60320 C14 plug and rated 10 A for standard inlets, while the AP9877 uses the larger IEC C20 and C19 connectors for high-draw equipment.

APC UPS systems keep servers and network cabinets running through outages and unstable mains, and the wider APC range extends into the racks, power distribution and sensors around them. APC began in the United States as American Power Conversion and
Browse brand productsDelivery across Saudi Arabia
Clear warranty
Some devices or frequencies may require a permit or approval depending on the intended use and the regulations in force in the Kingdom. Requirements are clarified before project orders are fulfilled.
Customer Reviews
No ratings yet for this product
Only logged in customers who have purchased this product may leave a review.
Related Products
APC SMX3000RMHV2U 3 kVA Smart-UPS, Rack/Tower Convertible
On backorder
APC SRV10KRIRK Online Rack UPS 10 kVA
On backorder
APC SRT1000XLI Smart-UPS Tower UPS 1000 VA / 1000 W
On backorder
APC SMV1000I Line Interactive UPS 1000 VA
On backorder





Reviews
There are no reviews yet.