Wholesale & retail - B2B/B2C
Free site survey in Riyadh
Shipping across the Kingdom
Warranty on all products
BrandAPC

APC E3MUPS60KHBS 60 kVA Three-Phase UPS for VRLA Batteries

A 60 kVA / 60 kW three-phase UPS from APC designed for 240 V VRLA batteries and supplied without them, for 400 V 3:3 installations.

Battery DetailsVRLAModelE3MUPS60KHBSPower60 kVA / 60 kW

Original price was: 41,345.71 SAR.Current price is: 38,864.97 SAR. excl. VAT

Available on backorder

WhatsApp Inquiry

RISYS can programme and prepare devices before delivery. Contact us for quantity and project details.

Wholesale and project supply — up to 45% off

Shipping and delivery icon
Fast shipping
SMSA Express logoFedEx logoNAQEL Express logoDHL logo
Product warranty icon
Genuine warranty
All products carry a one-year authorised-agent warranty.
Secure payment icon
Secure payment
madaVisaMastercardApple Pay
B2B sales icon
B2B/B2C supply

Up to 45% off wholesale supply.

Overview

The APC E3MUPS60KHBS delivers the full 60 kVA / 60 kW rating in a three-phase UPS designed for a 240 V VRLA battery set, supplied without the batteries themselves. That is its place among the three 60 kVA models: the battery purchase stays in the buyer’s hands while the battery technology and voltage are fixed in advance. For a facilities team that already holds a framework agreement with a battery supplier, or that wants to choose the battery brand and delivery date independently of the UPS, this model avoids paying for stored energy it does not need. It operates at 400 V with a 3:3 phase configuration, three-phase input and three-phase output, and its apparent and real power ratings match, so the full 60 kW can be planned as usable load. The result is a balanced middle option: the same rating, a defined battery specification, and the battery cost on a separate line the buyer controls.

How the APC E3MUPS60KHBS works once installed

Installed between the three-phase supply and the critical board, the UPS feeds the load from mains or generator in normal operation and transfers it to the VRLA batteries when the supply fails, holding it until power returns or the generator takes over. Because the batteries are ordered separately, backup time is decided when the battery set is specified, not when the UPS is bought. That helps when the runtime target is still being agreed with operations: the UPS can be ordered against the known load within 60 kW while the battery purchase runs in parallel.

The batteries must match the 240 V battery voltage and the VRLA type the unit is designed for. Do not schedule first start-up until the batteries are on site, since without them the UPS gives no cover during an outage.

Typical Saudi applications

The usual buyer is a government entity or large company that buys batteries through central contracts, or a contractor delivering several sites who wants one battery supplier across all of them. The unit suits data rooms in regional branch offices, CCTV and access-control head-ends in malls and hotels, control rooms in water and utility facilities, and hospital IT rooms where battery purchases go through a separate approval path.

APC E3MUPS60KHBS against its siblings

The E3MUPS60KHB2S shares the 60 kVA / 60 kW rating but ships with its batteries, which reduces procurement to one order. The E3MUPS60KHS shares the same rating but works with an external battery system, which suits a site planning a dedicated battery cabinet. Choose the E3MUPS60KHBS when you want the VRLA battery arrangement without buying the batteries on the same order. For heavier loads, the E3MUPS80KHS is rated at 80 kVA / 80 kW.

Deployment notes

Prepare a 400 V three-phase feed and a three-phase output to the protected board. Plan an air-conditioned room with space for the UPS and its batteries together, since VRLA batteries lose service life in heat. Fit the supplied dust filter and check it regularly on dusty sites, and follow the installation guide for cabling and the start-up sequence.

Package Contents

  • Dust filter
  • Installation guide

Technical Specifications

Brand
APC
Battery Details
VRLA
Model
E3MUPS60KHBS
Power
60 kVA / 60 kW

Frequently Asked Questions

Does the APC E3MUPS60KHBS come with batteries?

No. The unit is supplied without batteries, which are purchased separately.

Which batteries does it need?

VRLA batteries at a 240 V battery voltage, the specification the unit is designed for.

What electrical supply is required?

400 V with a 3:3 phase configuration: three-phase input and three-phase output.

When should I choose it over the E3MUPS60KHB2S?

When you buy batteries from your own approved supplier or under a separate contract. Both are rated at 60 kVA / 60 kW, but the E3MUPS60KHB2S ships with its batteries.

Brand
APC

APC UPS systems keep servers and network cabinets running through outages and unstable mains, and the wider APC range extends into the racks, power distribution and sensors around them. APC began in the United States as American Power Conversion and

Browse brand products
Shipping, Warranty and Regulatory

Delivery across Saudi Arabia

Clear warranty

Some devices or frequencies may require a permit or approval depending on the intended use and the regulations in force in the Kingdom. Requirements are clarified before project orders are fulfilled.

Customer Reviews

No ratings yet for this product

Reviews

There are no reviews yet.

Only logged in customers who have purchased this product may leave a review.

Related Products

APC

APC SCL500RMI1UC Lithium-Ion 400W 1U Rackmount UPS

Model SCL500RMI1UC
lithium-ion1U rackmount400W
Original price was: 2,182.91 SAR.Current price is: 2,051.94 SAR. excl. VAT Save 130.97 SAR

On backorder

Request a Quote
APC

APC SRVL2KRILRK Lithium-ion UPS 2000 VA

Model SRVL2KRILRK
Lithium-ionRack2000 VA
Original price was: 8,673.94 SAR.Current price is: 8,153.50 SAR. excl. VAT Save 520.44 SAR

On backorder

Request a Quote
APC

APC SMT2200RMI2UNC Smart-UPS 2200VA 2U with Network Card

Model SMT2200RMI2UNC
LCDRackmount 2U2200VA
Original price was: 7,609.11 SAR.Current price is: 7,152.56 SAR. excl. VAT Save 456.55 SAR

On backorder

Request a Quote
APC

APC SMV1000I Line Interactive UPS 1000 VA

Model SMV1000I
LCDTower230V
Original price was: 1,253.77 SAR.Current price is: 1,178.54 SAR. excl. VAT Save 75.23 SAR

On backorder

Request a Quote

Original price was: 41,345.71 SAR.Current price is: 38,864.97 SAR. excl. VAT