APC SBP3000 Service Bypass Panel, 30 A, 2U, Hardwired
A compact 2U service bypass panel rated 100-240 V and 30 A, with hardwired input and output, sized for smaller UPS installations.
Original price was: 3,250.52 SAR.3,055.49 SARCurrent price is: 3,055.49 SAR. excl. VAT
Available on backorder
RISYS can programme and prepare devices before delivery. Contact us for quantity and project details.
Wholesale and project supply — up to 45% off











Up to 45% off wholesale supply.
Overview
The APC SBP3000 is a service bypass panel for smaller UPS installations, and it trades size for flexibility. It carries a rated voltage of 100-240 V and a rated current of 30 A, occupies 2U of rack space, and connects by hardwire on both input and output, so it becomes a fixed part of the electrical installation rather than a plug-in accessory. Transfer is break-before-make (BBM): the load is disconnected for a moment as the panel switches between the UPS and the utility supply. Within this group of APC bypass panels it is the entry point, with a lower current rating than the SBP10KRMI4U and a wider voltage rating, which keeps it in proportion to a smaller UPS. Rack mounting brackets, an installation guide and a user manual come in the box.
What the APC SBP3000 does in practice
When the UPS needs a battery replacement, a repair or an upgrade, the SBP3000 moves its loads onto utility power so the UPS can be isolated and taken out safely. Because both sides are hardwired, the panel sits in the circuit between the supply, the UPS and the downstream distribution board or dedicated circuit that feeds the protected equipment. The break-before-make transfer has a practical consequence worth planning for: loads with a single power supply will see a brief interruption at the moment of transfer and may restart, while equipment with dual power supplies, the second on an independent feed, rides through it. Schedule transfers at a quiet time, warn users of single-corded devices in advance, and a UPS service visit becomes a short, controlled event instead of a full shutdown.
Where the SBP3000 fits on Saudi sites
The SBP3000 suits the many sites that run a modest UPS rather than a full data centre: clinic and pharmacy branches, school and university department server rooms, retail stores with point-of-sale and CCTV equipment, petrol-station back offices and small security control rooms. In these places the UPS often feeds a hardwired circuit for a small rack, a security panel or a network cabinet, and the 2U height takes little space in a partly filled rack. Its 100-240 V rating lets one panel model cover installations with different nominal supply voltages, which helps system integrators who standardise on a single bypass part across many branches.
SBP3000 versus the SBP10KRMI4U and SBP16KRMI4U
The SBP10KRMI4U is the heavier-duty option, with a higher current rating and IEC output sockets built into the panel so equipment plugs straight in. The SBP16KRMI4U is the other rack-mount bypass panel in the line; compare its ratings with your UPS before choosing. The SBP3000 is the right pick when the protected load is small, the output needs to be hardwired into an existing circuit, and rack space is limited. If the UPS draws more than the 30 A the SBP3000 is rated for, step up to the SBP10KRMI4U rather than running the SBP3000 at its limit.
Installation notes
Allow 2U of rack space and fix the panel with the supplied rack mounting brackets. Input and output terminations are hardwired, so a qualified electrician should make them and size the upstream protection and cabling for a 30 A circuit at the site’s supply voltage within the 100-240 V rating. Follow the installation guide for wiring and the user manual for the switching sequence, and record the break-before-make behaviour in the site’s maintenance procedure so that the brief interruption at transfer never comes as a surprise.
Package Contents
- Installation guide
- Rack mounting brackets
- User manual
Technical Specifications
- Brand
- APC
- Model
- SBP3000
Frequently Asked Questions
What are the electrical ratings of the APC SBP3000?
It is rated at 100-240 V and 30 A.
What does break-before-make (BBM) transfer mean for my equipment?
The load is disconnected briefly while the panel switches between the UPS and utility power, so single-corded devices may restart. Plan transfers for a quiet period and warn users beforehand.
How much rack space does the SBP3000 need?
It occupies 2U and ships with rack mounting brackets, an installation guide and a user manual.
Does the SBP3000 have outlets for plugging in equipment?
No. Both input and output are hardwired, so the panel connects to a distribution board or dedicated circuit that feeds the equipment.
When should I choose the SBP10KRMI4U instead of the SBP3000?
When the UPS draws more than the 30 A the SBP3000 is rated for, or when you want equipment to plug directly into IEC sockets built into the panel.

APC UPS systems keep servers and network cabinets running through outages and unstable mains, and the wider APC range extends into the racks, power distribution and sensors around them. APC began in the United States as American Power Conversion and
Browse brand productsDelivery across Saudi Arabia
Clear warranty
Some devices or frequencies may require a permit or approval depending on the intended use and the regulations in force in the Kingdom. Requirements are clarified before project orders are fulfilled.
Customer Reviews
No ratings yet for this product
Only logged in customers who have purchased this product may leave a review.
Related Products
APC SMT1500IC Smart-UPS Uninterruptible Power Supply
On backorder
APC BVX2200LI Tower UPS 2200 VA
On backorder
APC SMT2200IC Smart-UPS 2200VA 1980W Tower UPS
On backorder
APC SRT1000RMXLI 1000VA Online Smart-UPS, 2U Rackmount
On backorder





Reviews
There are no reviews yet.