The ZKTeco LM-2802 is the higher-force electromagnetic door lock in the ZKTeco electric lock family, rated at 280 kg (600 lb) of holding force. It is built for the doors where a standard lock leaves too little margin: main entrances, heavier single leaves, warehouse personnel doors and rooms that hold equipment or records worth protecting. The lock is powered to lock, so the door stays secured while current flows and releases the moment the supply is cut, which is the behaviour evacuation routes and fire-alarm interfaces depend on. ZKTeco specifies its draw at 420 mA at 12 V, a figure that makes supply sizing straightforward, and an operating range of -10 to +55 °C that covers air-conditioned interiors and shaded entrances alike.
How the ZKTeco LM-2802 behaves on a live door
Powered to lock means the access controller holds the door by keeping the lock energised and opens it by interrupting that power. A valid card, a fingerprint match, a keypad code or a press of the exit button all do the same thing electrically: they break the lock circuit for a few seconds, the magnetic hold collapses, and the door can be pushed open. When the circuit is restored and the door closes against the lock face, the 280 kg hold returns immediately. There is no bolt to throw and no latch to engage, so the door does not have to be pushed hard into its frame to secure.
The flip side of that design matters just as much. Any loss of power, whether from a tripped breaker, a supply fault or a deliberate fire-alarm release, unlocks the door. For egress doors this is exactly what safety planning calls for; for a door that must stay secured through a power cut, the supply needs battery backup sized for the expected outage.
Power and environment planning
At 420 mA at 12 V, the LM-2802 lets you budget the lock supply per door before installation. Add the lock’s draw to that of the reader and controller sharing the same supply, then leave headroom so the supply is not running at its limit. Where several locks share one supply, total each lock’s draw rather than estimating, and size any backup battery against that total and the hours of hold-up the site requires.
The rated operating temperature of -10 to +55 °C suits indoor doors and entrances under a canopy or in shade. On an exposed door in direct Saudi summer sun, a metal frame can heat beyond the surrounding air, so check the real temperature at the mounting point against the +55 °C ceiling and favour a shaded side of the frame where the layout allows.
Saudi sites that call for the LM-2802
The extra holding force earns its place at the main entrance of a corporate office, the staff door of a logistics warehouse in the industrial cities of Riyadh and Dammam, and the entrance to data rooms and telecom rooms. Hospitals use higher-force locks on pharmacy stores and controlled-medicine rooms; banks and exchange offices apply them to back-office doors and vault anterooms; schools fit them to the main doors of administration buildings and to equipment stores. Government buildings with steady visitor flows use them on the reception door that must resist being forced yet open instantly on a fire alarm.
LM-2802 or LM-1802: choosing within the family
The LM-1802 is the balanced option for ordinary interior doors; the LM-2802 steps up in holding force for doors where force resistance is part of the brief. If the door is a standard office or meeting-room leaf with light traffic, the LM-1802 is usually enough. Choose the LM-2802 for primary entrances, heavier or taller leaves, doors that face public areas, and rooms where an attempted forced entry is a realistic concern. Where the door needs a bracket, confirm that the bracket’s compatibility list names the LM-2802; the LMB-180U, for example, is listed for the LM-1802 rather than this model.
Deployment notes
Wire the lock through the controller’s relay so the reader, the exit button and the emergency break-glass unit all interrupt the same circuit. On escape routes, connect the supply to the fire alarm interface so an alarm cuts lock power for every door on that route. Fit the lock body to the frame header and the iron plate to the door so the faces meet flat and fully when the door closes, since partial contact reduces holding force. Use a door closer that brings the leaf fully against the lock every time; a door left resting short of the lock face is a door that is not held.
Technical Specifications
- Brand
- ZKTeco
- Device Type
- Electromagnetic door lock
- Model
- LM-2802
Frequently Asked Questions
What is the holding force of the ZKTeco LM-2802?
It is rated at 280 kg (600 lb), the highest holding force among the locks in this family.
Does the door unlock during a power cut?
Yes. The LM-2802 is powered to lock, so removing power releases it. To keep a door locked through an outage, feed it from a battery-backed supply.
How much current does the LM-2802 draw?
It draws 420 mA at 12 V; total that figure for every lock when sizing the power supply and backup battery.
Can it be installed at an outdoor entrance?
Its operating range is -10 to +55 °C, which suits indoor doors and shaded entrances. For a door in direct sun, check the temperature at the mounting point first.

Browse ZKTeco access control and time attendance equipment in one place: face and fingerprint terminals, door controllers, card readers, electric locks, hotel locks and vehicle barriers for offices, hotels and compounds across Saudi Arabia. ZKTeco is a Chinese biometrics manufacturer
Browse brand productsDelivery across Saudi Arabia
Clear warranty
Some devices or frequencies may require a permit or approval depending on the intended use and the regulations in force in the Kingdom. Requirements are clarified before project orders are fulfilled.
Customer Reviews
No ratings yet for this product
Only logged in customers who have purchased this product may leave a review.
Related Products
ZKTeco 131 N0 Electric Strike – Recessed
On backorder
ZKTeco LM-1802 Electromagnetic Door Lock 180 kg 12/24V
On backorder
ZKTeco LMB-180ZL ZL Bracket for Electromagnetic Locks
On backorder
ZKTeco LMB-280U U Bracket for Glass Door Magnetic Locks
On backorder





Reviews
There are no reviews yet.