APC AP7821B Metered Rack PDU, 16A, 1U, 8 x C13
A metered rack PDU for heavier server loads: maximum current of 16A at 208-230V through a C20 input plug, with 8 IEC 60320 C13 outlets in a 1U chassis.
Original price was: 2,280.36 SAR.2,143.54 SARCurrent price is: 2,143.54 SAR. excl. VAT
Available on backorder
RISYS can programme and prepare devices before delivery. Contact us for quantity and project details.
Wholesale and project supply — up to 45% off











Up to 45% off wholesale supply.
Overview
Where a rack draws more than a light network load, the APC AP7821B is the metered PDU to specify. It is rated for a maximum current of 16A at 208-230V, takes power through an IEC 60320 C20 input plug, and distributes it across 8 IEC 60320 C13 outlets in a 1U horizontal unit that mounts at the front or rear of the rack. The C20 plug is the higher-current connector in the IEC 60320 family, so the unit draws from a matching heavy-duty socket on a UPS or an upstream distribution point rather than from an ordinary equipment outlet. In practice this gives one cabinet of servers, storage and switching a feed sized for real working load, while the meter shows how much of the 16A budget is already committed before the next device goes in.
Choosing the APC AP7821B over the AP7820B
The two units share the horizontal chassis and the C13 outlet layout, so the decision rests on current and the input plug. The AP7820B is limited to a maximum of 12A at 208V and 10A at 230V, while the AP7821B raises that ceiling to 16A across 208-230V. If the measured or planned rack load sits comfortably below the limit of the AP7820B, the lighter model is enough. If it is close to that limit, or the rack is expected to take more servers over its life, the AP7821B avoids a replacement later. For racks heading beyond 16A, the AP7822B moves to an input of 32 A on an IEC 60309 connector with a larger outlet complement, which is a different installation altogether.
Day-to-day operation
Every one of the 8 C13 outlets accepts the short IEC jumper cords used to power servers, NAS units, switches and firewalls inside a rack, so equipment plugs in directly. The meter is the practical advantage over an unmetered strip: when an operations team is asked whether a rack can take another server, the answer comes from a reading at the PDU rather than from guesswork about nameplate figures. Mounting the unit at the rear keeps it next to the power supplies it feeds, shortening cords and leaving the front of the rack for equipment. The cord retention bracket included in the box holds plugs firmly in their outlets, which matters in racks where technicians work frequently.
Saudi deployments that suit the AP7821B
The AP7821B fits rooms where a single cabinet carries real compute: an on-premises server rack in a hospital records department, a video management server and storage array in the central security room of a mall, an ERP server cabinet at a logistics company in the Second Industrial City, or the main rack of a university faculty building. In each case the load is heavier than a branch-office network cabinet but still within one 16A feed. Contractors fitting out new commercial towers in Riyadh, Jeddah and the Eastern Province can specify it for tenant server rooms where the eventual load is not yet known, since the meter lets the facility team audit consumption after occupancy.
Installation checklist
Confirm that the upstream source offers a C20-compatible high-current socket, whether that is a UPS output or a rack-level distribution point. Add up the expected draw of the connected equipment and keep it below 16A with headroom. Reserve 1U in the rack, front or rear, and fit the supplied rack mounting brackets. The unit carries a warranty of 24 months from APC.
Package Contents
- Cord retention bracket
- Installation guide
- Rack mounting brackets
- User manual
Technical Specifications
- Brand
- APC
- Warranty
- 2 Years
- Model
- AP7821B
- Mounting
- 1U, horizontal, rack-mounted, front and rear
- Power
- Max current 16A, 208-230V
Frequently Asked Questions
What is the maximum current of the APC AP7821B?
It is rated for a maximum current of 16A at 208-230V. Keep the connected load below that figure, with headroom.
What does the C20 input plug need upstream?
A matching C20-compatible high-current socket on a UPS or a distribution point, not an ordinary equipment outlet.
How many outlets does the AP7821B have?
It has 8 IEC 60320 C13 outlets in a 1U horizontal chassis.
How does it differ from the AP7820B?
The AP7820B is limited to a maximum of 12A at 208V and 10A at 230V, while the AP7821B reaches 16A at 208-230V and uses a C20 input plug.
What warranty does it carry?
APC covers the unit with a warranty of 24 months.

APC UPS systems keep servers and network cabinets running through outages and unstable mains, and the wider APC range extends into the racks, power distribution and sensors around them. APC began in the United States as American Power Conversion and
Browse brand productsDelivery across Saudi Arabia
Clear warranty
Some devices or frequencies may require a permit or approval depending on the intended use and the regulations in force in the Kingdom. Requirements are clarified before project orders are fulfilled.
Customer Reviews
No ratings yet for this product
Only logged in customers who have purchased this product may leave a review.
Related Products
APC AP8653 Metered-by-Outlet Switched Rack PDU 32A
On backorder
APC AP4423A Rack Transfer Switch 1U 16A, 3700 VA
On backorder
APC AP6020A Zero U Rack PDU, 13 C13 Outlets, C20 Inlet
On backorder
APC AP8886 Metered Rack PDU, 32A Three-Phase 400V
On backorder





Reviews
There are no reviews yet.