APC AP8858EU3 Metered Rack PDU, 0U, 3.7 kW, IEC 60309 Plug

A 0U APC metered rack PDU rated 3.7 kW at 16 A, with 18 C13 and 2 C19 outlets and a 2.9 m locking input cord ending in an IEC 60309 16 A 2P + E plug.

ModelAP8858EU3Mounting0UPower3.7 kW

Original price was: 3,570.57 SAR.Current price is: 3,356.34 SAR. excl. VAT

Available on backorder

WhatsApp Inquiry

RISYS can programme and prepare devices before delivery. Contact us for quantity and project details.

Wholesale and project supply — up to 45% off

Minimum order5 units

Shipping and delivery icon
Fast shipping
SMSA Express logoFedEx logoNAQEL Express logoDHL logo
Product warranty icon
Genuine warranty
All products carry a one-year authorised-agent warranty.
Secure payment icon
Secure payment
madaVisaMastercardApple Pay
B2B sales icon
B2B/B2C supply

Up to 45% off wholesale supply.

Overview

The APC AP8858EU3 is a metered rack PDU built for cabinets fed from an industrial-style socket. What sets it apart in the APC family is how power reaches it: a locking input power cord, 2.9 m long, ending in an IEC 60309 16 A 2P + E plug, giving the unit a capacity of 3.7 kW on a single-phase 16 A supply. That plug is the round, keyed connector specified in many data centres and plant rooms, and it mates only with a matching socket, which reduces the chance of a cabinet being fed from an outlet rated below its needs. The unit mounts at 0U in the rear channel of the rack and carries 18 C13 outlets and 2 C19 outlets. As a metered model it measures the load passing through it, so the team running the room can compare the cabinet’s draw against its 16 A limit.

Why the input cord matters on the APC AP8858EU3

Most decisions in rack power design are made at the wall, not at the outlets. A PDU that arrives with its own locking cord and an IEC 60309 plug is ready to connect to the socket the electrical contractor has already installed under the raised floor or on the overhead tray. There is no separate cord to source, size or match, and the locking design keeps the cord from working loose during maintenance in a crowded cabinet. The cord length of 2.9 m gives enough reach to run from the rear of the rack to a floor box or a tray above, though the socket position should still be checked against that length before installation. A single input cable feeds the whole unit, which keeps the electrical side of the cabinet simple to trace and to label.

Measured load and outlet mix

Being metered, the unit measures the current flowing through it. On a 16 A feed that information has real value: a cabinet that creeps toward its limit as equipment is added will eventually trip the upstream breaker and drop every device on the strip at the same moment. Checking the measured load before each addition lets the team decide whether the next server goes into this cabinet or the next one. The 18 C13 outlets take the standard cords used by servers, access and distribution switches, firewalls, routers and network video recorders. The 2 C19 outlets serve heavier equipment: storage enclosures, chassis-based switches and high-draw servers whose power supplies use the larger connector. Output to the outlets is rated at 230 V, and the unit accepts a nominal input of 200 V, 208 V or 230 V.

Where the AP8858EU3 fits in Saudi projects

Many data halls run by telecom carriers and colocation providers in Riyadh, Jeddah and Dammam deliver power to each cabinet through industrial sockets, and this unit plugs straight into that infrastructure. The same applies to equipment rooms in hospitals, banks and ministries where the electrical contractor has standardised on IEC 60309 outlets for IT loads. In petrochemical and utility control buildings, where a cabinet may hold SCADA servers, historians and network gear, the locking cord adds a practical safeguard against accidental disconnection. Security integrators building central monitoring rooms can place recorders, video management servers and core switches on the C13 outlets and keep the C19 outlets for the storage arrays that hold weeks of footage.

AP8858EU3 or AP8858: picking the right variant

The two models share the metered design, the same mix of C13 and C19 outlets and the same 0U form. What separates them is the connection to the building. The AP8858 uses an inlet that takes a separately chosen cord and is rated 3.3kW at 208V 16A or 3.7kW at 230V 16A. Choose the AP8858EU3 when the room is already fitted with IEC 60309 16 A sockets and you want the cord delivered with the unit; choose the AP8858 when the cord has to suit a different socket type or a UPS output. For larger loads, the AP8881 moves to three-phase power at 11 kW. The AP8886 is rated at 32 A.

Installation checklist

Rack and mounting

Confirm that the cabinet has 0U mounting points in its rear channel and enough depth behind the equipment for a vertical strip. The rack mounting brackets in the box fix the unit in place, and the installation guide shows the positions.

Electrical supply

Provide a single-phase 16 A circuit terminated in an IEC 60309 16 A 2P + E socket within reach of the 2.9 m cord. Keep the total connected load within the 3.7 kW rating, and spread high-draw equipment so the measured figure leaves headroom.

Setup and warranty

The serial configuration cable in the box is used for initial setup, and the safety guide should be read before the unit is energised. The AP8858EU3 carries a 24-month warranty.

Package Contents

  • Installation guide
  • Locking input power cord
  • Rack mounting brackets
  • Serial configuration cable
  • Safety guide

Technical Specifications

Brand
APC
Warranty
2 Years
Model
AP8858EU3
Mounting
0U
Power
3.7 kW

Frequently Asked Questions

What plug does the APC AP8858EU3 use?

It ships with a locking input power cord, 2.9 m long, ending in an IEC 60309 16 A 2P + E plug.

Which input voltages does it accept?

A nominal input of 200 V, 208 V or 230 V. Output to the outlets is rated at 230 V.

What is its maximum capacity?

3.7 kW, with a 16 A input current limit.

How does it differ from the AP8858?

Both share the metered design, the 0U form and 18 C13 plus 2 C19 outlets. The AP8858EU3 comes with the locking IEC 60309 cord, while the AP8858 takes a separately chosen cord.

Is the AP8858EU3 single-phase or three-phase?

Single-phase. For a three-phase cabinet feed, the AP8881 is the metered option in the same family.

Brand
APC

APC UPS systems keep servers and network cabinets running through outages and unstable mains, and the wider APC range extends into the racks, power distribution and sensors around them. APC began in the United States as American Power Conversion and

Browse brand products
Shipping, Warranty and Regulatory

Delivery across Saudi Arabia

Clear warranty

Some devices or frequencies may require a permit or approval depending on the intended use and the regulations in force in the Kingdom. Requirements are clarified before project orders are fulfilled.

Customer Reviews

No ratings yet for this product

Reviews

There are no reviews yet.

Only logged in customers who have purchased this product may leave a review.

Related Products

APC

APC AP6032A Rack PDU, 4 C19 Outlets, 32A IEC 60309 Input

Model AP6032A
230V
Original price was: 850.14 SAR.Current price is: 799.13 SAR. excl. VAT Save 51.01 SAR

On backorder

Request a Quote
APC

APC AP6015A 1U Rack PDU, 8 C13 Outlets, 15A Input

Model AP6015A
1U horizontal design240V
Original price was: 295.05 SAR.Current price is: 277.35 SAR. excl. VAT Save 17.70 SAR

On backorder

Request a Quote
APC

APC ER7PDUBRKTS Single-Width PDU Mounting Bracket Kit

Model ER7PDUBRKTS
Original price was: 110.98 SAR.Current price is: 104.32 SAR. excl. VAT Save 6.66 SAR

On backorder

Request a Quote
APC

APC AP6020A Zero U Rack PDU, 13 C13 Outlets, C20 Inlet

Model AP6020A
2 YearsZero UInput 100-240 volts
Original price was: 385.06 SAR.Current price is: 361.96 SAR. excl. VAT Save 23.10 SAR

On backorder

Request a Quote

Original price was: 3,570.57 SAR.Current price is: 3,356.34 SAR. excl. VAT